The basic prototype of a tile hadron calorimeter (HCAL) for the International Linear Collider (ILC) has been realised and extensively tested. A major aspect of the proposed concept is the improvement of the jet energy resolution by…
The electromagnetic calorimeter (ECAL) is a key detector component for precise electron and photon measurements in electron-ion collision experiments. At the Electron-Ion Collider in China (EicC), high-performance calorimetry is essential…
The FCAL collaboration has performed a design study for luminometers at future electronpositron colliders. Compact sampling calorimeters with precisely positioned silicon sensors and a fast readout will reach the necessary performance even…
The Analog Hadron Calorimeter (AHCAL) concept developed by the CALICE collaboration is a highly granular sampling calorimeter with \SI{3x3}{\square\centi\meter} plastic scintillator tiles individually read out by silicon photomultipliers…
A novel technique for longitudinal segmentation of shashlik calorimeters has been tested in the CERN West Area beam facility. A 25 tower very fine samplings e.m. calorimeter has been built with vacuum photodiodes inserted in the first 8…
We outline a physics program at Fermilab that would significantly improve our ability to understand the behavior of hadronic showers in calorimeters. This would involve a two-pronged approach designed to measure particle production cross…
The Tile Calorimeter (TileCal) is the hadronic calorimeter covering the most central region of the ATLAS experiment at the LHC. It is a key detector for the measurement of hadrons, jets, tau leptons and missing transverse energy. The…
The fine-sampling electromagnetic calorimeter prototype has been experimentally tested using the 1-19 GeV/c tagged beams of negatively charged particles at the U70 accelerator at IHEP, Protvino. The energy resolution measured by electrons…
A novel design for a silicon-tungsten electromagnetic calorimeter is described, based on Monolithic Active Pixel Sensors (MAPS). A test sensor with a pixel size of 50x50 um2 has been fabricated in July 2007. The simulation of the physical…
This article describes the Laser calibration system of the Atlas hadronic Tile Calorimeter that has been used during the run 1 of the LHC. First, the stability of the system associated readout electronics is studied. It is found to be…
A forward electromagnetic calorimeter (FoCal) based on SiW technology is being considered as a possible upgrade to the ALICE detector. This device should in particular feature an extremely high granularity allowing gamma/pi0 discrimination…
The CMS Collaboration is preparing to build replacement endcap calorimeters for the HL-LHC era. The new high-granularity calorimeter (HGCAL) is, as the name implies, a highly-granular sampling calorimeter with approximately six million…
In this talk I discuss the use of calorimeter timing both for detector commissioning and in searches for new physics. In particular I present real and simulated cosmic ray muons data results for the ATLAS Tile Calorimeter system. The…
We constructed a large-scale electromagnetic calorimeter prototype as a part of the Forward Calorimeter upgrade project (FoCal) for the ALICE experiment at the Large Hadron Collider (LHC). The prototype, also known as ``Mini FoCal'',…
The CEBAF Large Acceptnace Spectrometer (CLAS) has been taking production data since February, 1998. It takes data for many reactions simultaneously with moderate resolution. Data has been taken for a variety of conditions with polarized…
The MAPS prototype of the proposed ALICE Forward Calorimeter (FoCal) is the highest granularity electromagnetic calorimeter, with 39 million pixels of $30 \times 30 \mu$m$^{2}$. Particle showers can be studied with unprecedented detail with…
Precision physics at future multi-TeV lepton colliders such as CLIC requires excellent jet energy resolution. The detectors need deep calorimeter systems to limit the energy leakage also for very highly energetic particles and jets. At the…
The ATLAS liquid argon calorimeter has been operating continuously since August 2006. At this time, only part of the calorimeter was readout, but since the beginning of 2008, all calorimeter cells have been connected to the ATLAS readout…
A prototype Scintillator-Tungsten electromagnetic calorimeter (ScECAL) for the ILC detector was tested in 2008 at the Fermilab test beam. Data were collected with electron, pion and muon beams in the energy range 1 to 32GeV combined with…
A calorimeter was built to measure the heat from a porous capacitive working electrode connected in a three-electrode configuration. This makes it possible to detect differences between cathodic and anodic heat production. The…