English
Related papers

Related papers: Monitoring of the accelerator beam distributions f…

200 papers

The EDDA-Detector at the Cooler-Synchrotron COSY/J\"ulich has been operated with an internal CH$_2$ fiber target to measure proton-proton elastic scattering differential cross sections. For the data analysis knowledge of beam parameters,…

The complex non-linear processes in multi-dimensional parameter spaces, that are typical for an accelerator, are a natural application for machine learning algorithms. This paper reports on the use of Bayesian optimization for the…

Accelerator Physics · Physics 2023-04-26 A. Awal , J. Hetzel , R. Gebel , V. Kamerdzhiev , J. Pretz

A beam profile monitor utilizing visible synchrotron radiation (SR) from a bending magnet has been designed and installed in Cornell Electron-Positron Storage Ring (CESR). The monitor employs a double-slit interferometer to measure both the…

Accelerator Physics · Physics 2014-05-30 S. T. Wang , D. L. Rubin , J. Conway , M. Palmer , D. Hartill , R. Campbell , R. Holtzapple

The vector and tensor polarizations of a deuteron beam have been measured using elastic deuteron-carbon scattering at 75.6 MeV and deuteron-proton scattering at 270 MeV. After acceleration to 1170 MeV inside the COSY ring, the polarizations…

We study the modifications of synchrotron radiation of charges in a storage ring as they are cooled. The pair correlation lengths between the charges are manifest in the synchrotron radiation and coherence effects exist for wavelengths…

Accelerator Physics · Physics 2009-10-31 Harel Primack , Reinhold Blümel

A compact beam-profile monitor was constructed using a linear contact image sensor attached to a plastic scintillator and tested using a 230 MeV proton beam. The results indicate that the beam distribution can be obtained in real-time, and…

Medical Physics · Physics 2019-12-23 Tung-Yuan Hsiao , Tzung-Yuang Chen , Huan Niu , Chien-Hsu Chen

The self-consistent nonlinear dynamics of a relativistic charged particle beam interacting with its complete self-fields is a fundamental problem underpinning many of the accelerator design issues in high brightness beam applications, as…

Accelerator Physics · Physics 2022-06-01 C. -K. Huang , F. -Y. Li , H. N. Rakotoarivelo , B. Shen , J. Domine , B. Carlsten , G. Dilts , R. Garimella , T. Kwan , R. Robey

Synchrotron radiation has been used for many years as a beam diagnostic at electron accelerators. It is not normally associated with proton accelerators as the intensity of the radiation is too weak to make detection practical. However, if…

Instrumentation and Detectors · Physics 2011-10-17 R. Thurman-Keup , H. W. K. Cheung , A. Hahn , P. Hurh , E. Lorman , C. Lundberg , T. Meyer , D. Miller , S. Pordes , A. Valishev

Synchrotron radiation with the characteristic of high brilliance, high level of polarization, high collimation, low emittance and wide tunability in energy has been used as a standard source in metrology(1, 2). For a decade, lots of…

Instrumentation and Detectors · Physics 2019-08-17 LI Hua-Peng , Kun Tang , Yi-Dong Zhao , Lei Zheng , Shu-Hu Liu , Xiao-Liang Zhao , Ya-Shuai Zhao

On-line monitoring of beam quality for high brightness beams is only possible using non-invasive instruments. For matching measurements, very few such instruments are available. One candidate is a quadrupole pick-up. Therefore, a new type…

Accelerator Physics · Physics 2009-11-07 Andreas Jansson

We present a measurement of the transverse intensity distributions of the COSY proton beam at the target interaction point at ANKE at the injection energy of 45 MeV, and after acceleration at 2.65 GeV. At 2.65 GeV, the machine acceptance…

Precise calculation of the geometrical acceptance of a large solid angle detector with an integrated stopping target relies on precise knowledge of the beam geometry. We describe four alternative methods that we used to measure the beam…

High Energy Physics - Experiment · Physics 2008-11-26 E. Frlez , M. Bychkov , W. Li , D. Pocanic

Purpose: To measure dispersion of a clinical proton therapy beam. Methods and Materials: The proton center at our institution uses a Hitachi PROBEAT V synchrotron that delivers beams with energies ranging from 70 to 230 MeV to five…

Medical Physics · Physics 2018-05-02 Satomi Shiraishi , Michael G. Herman , Keith M. Furutani

A new, compact beam position monitor based on segmented a toroidal coil surrounding the charged particle beam has been investigated. It makes use of the induced voltages in the windings instead of the induced charge imbalance on capacitor…

Through the simultaneous measurement of the transverse size as a function of longitudinal position, and the longitudinal distribution of luminosity, we are able to measure the $\beta_y^\ast$ (vertical envelope function at the collision…

Accelerator Physics · Physics 2009-11-06 D. Cinabro , K. Korbiak , R. Ehrlich , S. Henderson , N. Mistry

A telescope of three silicon detectors has been installed close to the internal target position of the ANKE spectrometer, which is situated inside the ultra-high vacuum of the COSY-Juelich light-ion storage ring. The detection and…

The repeated passage of a coasting ion beam of a storage ring through a thin target induces a shift in the revolution frequency due to the energy loss in the target. Since the frequency shift is proportional to the beam-target overlap, its…

Synchrotron radiation facilities provide highly polarized X-ray beams across a wide energy range. However, the exact type and degree of polarization varies according to the beamline and experimental setup. To accurately determine the angle…

Instrumentation and Detectors · Physics 2024-05-31 L. Manzanillas , J. M. Ablett , M. Choukroun , F. J. Iguaz , J. P. Rueff

We study collisions between neutral, deuterated ammonia molecules (ND$_3$) stored in a 50 cm diameter synchrotron and argon atoms in co-propagating supersonic beams. The advantages of using a synchrotron in collision studies are twofold:…

‹ Prev 1 2 3 10 Next ›