English
Related papers

Related papers: Imaging Gaseous Detector based on Micro Processing…

200 papers

Since long time, the compelling scientific goals of future high energy physics experiments were a driving factor in the development of advanced detector technologies. A true innovation in detector instrumentation concepts came in 1968, with…

Instrumentation and Detectors · Physics 2010-08-25 Maxim Titov

A centenary after the invention of the basic principle of gas amplification, gaseous detectors - are still the first choice whenever the large area coverage with low material budget is required. Advances in photo-lithography and…

Instrumentation and Detectors · Physics 2013-08-16 Maxim Titov

Gaseous detectors are fundamental components of all present and planned high energy physics experiments. Over the past decade two representatives (GEM, Micromegas) of the Micro-Pattern Gas Detector (MPGD) concept have become increasingly…

Instrumentation and Detectors · Physics 2008-11-26 Maxim Titov

We have developed microstrip gas counters manufactured on standard printed circuit board and having the following features: resistive cathode strips, thin (10 micron) metallic anode strips and electrodes protected against surface discharges…

Instrumentation and Detectors · Physics 2011-07-28 R. Oliveira , V. Peskov , F. Pietropaolo , P. Picchi

A novel gaseous two-dimensional imaging detector "Micro Pixel Chamber (micro-PIC)" has been developed. This detector is based on double sided printed circuit board (PCB). We have developed large area (10cm x 10cm) micro-PICs with 65536…

High Energy Physics - Experiment · Physics 2015-06-25 T. Nagayoshi , H. Kubo , K. Miuchi , A. Ochi , R. Orito , A. Takada , T. Tanimori , M. Ueno

A new family of spark-protected micropattern gaseous detectors is introduced: a 2-D sensitive restive microstrip counter and hybrid detectors, which combine in one design a resistive GEM with a microstrip detector. These novel detectors…

Instrumentation and Detectors · Physics 2011-08-31 P. Martinengo , E. Nappi , R. Oliveira , V. Peskov , P. Pietropaolo , P. Picchi

We describe the first tests with a new proportional gas detector. Its geometry consists in slits opened in a copper metallized kapton foil with 30 micron anode strips suspended in these openings. In this way the multiplication process is…

Instrumentation and Detectors · Physics 2007-05-23 J. Claude Labbe , F. Gomez , T. Nunez , A. Pazos , P. Vazquez

In the last decade, several new imaging gaseous detectors, called micro-pattern gaseous detectors, have been conceived and rapidly developed. In this paper, the most popular designs of these detectors and their applications to high energy…

Instrumentation and Detectors · Physics 2009-06-30 V. Peskov

Micro-TPC, a time projection chamber(TPC) with micro pixel chamber($\mu$-PIC) readout was developed for the detection of the three-dimensional fine(sub-m illimeter) tracks of charged particles. We developed a two-dimensional position…

High Energy Physics - Experiment · Physics 2009-11-10 Kentaro Miuchi , Hidetoshi Kubo , Tsutomu Nagayoshi , Atsuhiko Ochi , Reiko Orito , Atsushi Takada , Toru Tanimori , Masaru Ueno

We give a short compendium of the main ongoing detectors and concepts capable of performing accurate sub-100 ps timing at high particle fluxes and on large areas, through technologies based on gaseous media. We briefly discuss the…

Instrumentation and Detectors · Physics 2017-04-05 D. Gonzalez-Diaz , F. R. Palomo , J. Gonzalez , H. Chen

We present results from further tests of Microstrip Gas Counters (MSGCs) with resistive electrodes. The maim advantage of this detector is that it is spark-protected: in contrast to "classical" MSGCs with metallic electrodes, sparks in this…

Instrumentation and Detectors · Physics 2011-01-20 R. Oliveira , V. Peskov , Pietropaolo , P. Picchi

Gas detectors are one of the pillars of the research in fundamental physics. Since many years, a new concept of detectors, the Micro Pattern Gas Detectors, allows to overcome many of the problems of other types of commonly used detectors,…

A quality assurance and performance qualification laboratory was built at McGill University for the Canadian-made small-strip Thin Gap Chamber (sTGC) muon detectors produced for the 2019-2020 ATLAS experiment muon spectrometer upgrade. The…

We discuss a new class of Micro Pattern Gas Detectors, the Gas Pixel Detector (GPD), in which a complete integration between the gas amplification structure and the read-out electronics has been reached. An Application-Specific Integrated…

We describe here various detectors designs: GEM type, MICROMEGAStype, PPACtype as well as cascaded detectors made of a resistive mesh manufactured from a resistive Kapton foil, (20 microns thick, resistivity a few MOhm per square) by a…

Instrumentation and Detectors · Physics 2017-10-11 R. Oliveira , V. Peskov , F. Pietropaolo , P. Picchi

The first successful attempts to optimize the electric field in Resistive Microstrip Gas Chamber (RMSGC) using additional field shaping strips located inside the detector substrate are described.

Instrumentation and Detectors · Physics 2014-04-01 R. Oliveira , S. Franchino , V. Peskov

In this work, we have tried to develop a detailed understanding of the physical processes occurring in those variants of Micro Pattern Gas Detectors (MPGDs) that share micro hole and micro strip geometry, like GEM, MHSP and MSGC etc. Some…

Instrumentation and Detectors · Physics 2016-05-11 Purba Bhattacharya , Supratik Mukhopadhyay , Nayana Majumdar , Sudeb Bhattacharya

The paper summarizes our latest progress in the development of newly introduced micro pattern gaseous detectors with resistive electrodes. These resistive electrodes protect the detector and the front-end electronics in case of occasional…

Instrumentation and Detectors · Physics 2008-11-26 A. Di Mauro , B. Lund-Jensen , P. Martinengo , E. Nappi , R. Oliveira , V. Peskov , L. Periale , P. Picchi , F. Pietropaolo , I. Rodionov , J. C. Santiard

A prototype Gas Electron Multiplier (GEM) detector is under construction for medical imaging purposes. A single thick GEM of size 10x10 cm^2 is assembled inside a square shaped air-tight box which is made of Perspex glass. In order to…

Instrumentation and Detectors · Physics 2013-07-05 N. N. Mondal , S. Chattopadhyay , M. R. Dutta Mazumdar , A. K. Dubey , Y. P. Vioygi

The Inner Tracker System of the HERA-B experiment at DESY consists of 184 Microstrip Gas Chambers (MSGC) with a total number of 147 456 electronic read out channels. The detectors have to cope with particle fluxes up to 25 kHz/mm**2 and to…

Instrumentation and Detectors · Physics 2007-05-23 Bernhard Schmidt
‹ Prev 1 2 3 10 Next ›