English
Related papers

Related papers: The Design and Performance of the ZEUS Central Tra…

200 papers

The architecture of the ZEUS Micro Vertex Detector data acquisition system and the implementation of its second level trigger, the ZEUS Global Track Trigger are described. Data from the vertex detectors HELIX read-out chips, corresponding…

Instrumentation and Detectors · Physics 2011-07-19 Alessandro Polini

The laser alignment system of the ZEUS microvertex detector is described. The detector was installed in 2001 as part of an upgrade programme in preparation for the second phase of electron-proton physics at the HERA collider. The alignment…

Instrumentation and Detectors · Physics 2008-08-07 K. Korcsak-Gorzo , G. Grzelak , K. Oliver , M. Dawson , R. Devenish , J. Ferrando , T. Matsushita , P. Shield , R. Walczak

In this note we present a mathematical framework for a rigorous approach to a common track fit for trackers located in the inner region of the ZEUS detector. The approach makes use of the Kalman filter and offers a rigorous treatment of…

Data Analysis, Statistics and Probability · Physics 2008-12-09 Alexander Spiridonov

For the advancement of the understanding of timing systematics in pixelized readout chips and for the benefit of future fast timing detectors to aid 4D tracking technology in the HL-LHC, we have performed detailed studies of the timing…

Instrumentation and Detectors · Physics 2022-01-25 R. Geertsema

Time-tagging units and coincidence detectors are used in many scientific research fields. The required timing resolution and number of input channels are varying, but some emerging experiments in the field of quantum optics require up to 32…

Instrumentation and Detectors · Physics 2020-11-03 Attila Hidvegi

Silicon tracking detectors provide excellent spatial resolution, and so can provide excellent momentum resolution for energetic charged particles, even in compact detectors. However, at lower momenta, multiple scattering in the silicon…

Instrumentation and Detectors · Physics 2020-04-22 Spencer R. Klein

The design of a detector system comprised of four silicon sensors bump-bonded to Timepix4 ASICs is described together with its data acquisition system, operational infrastructure, and dedicated software. The spatial and temporal performance…

We propose a novel fast track finding system capable of reconstructing four dimensional particle trajectories in real time using precise space and time information of the hits. Recent developments in silicon pixel detectors achieved 150 ps…

Instrumentation and Detectors · Physics 2015-12-31 Nicola Neri , Marco Petruzzo

The production of D+- and D0 mesons has been measured with the ZEUS detector at HERA using an integrated luminosity of 133.6 pb-1. The measurements cover the kinematic range 5 < Q^2 < 1000 GeV^2, 0.02 < y < 0.7, 1.5 < p_T^D < 15 GeV and…

High Energy Physics - Experiment · Physics 2010-01-11 ZEUS Collaboration , S. Chekanov

We have developed a new laser-based time calibration system for highly segmented scintillator counters like the MEG II pixelated Timing Counter (pTC), consisting of 512-centimeter scale scintillator counters read out by silicon…

Central exclusive processes can be studied in CMS by combining the information of the central detector with the Precision Proton Spectrometer (PPS). PPS detectors, placed symmetrically at more than 200 m from the interaction point, can…

Instrumentation and Detectors · Physics 2020-06-24 Edoardo Bossini

During the HERA luminosity shutdown period 2000/01 the tracking system of the ZEUS experiment has been upgraded with a silicon Micro Vertex Detector (MVD). The barrel part of the detector consists of three layers of single sided silicon…

High Energy Physics - Experiment · Physics 2009-11-07 V. Chiochia

A new method is employed to measure the neutral current cross section up to Bjorken-x values of one with the ZEUS detector at HERA using an integrated luminosity of 65.1 pb-1 for e+p collisions and 16.7 pb-1 for e-p collisions at…

High Energy Physics - Experiment · Physics 2012-08-27 ZEUS Collaboration

This paper describes the data acquisition and trigger system of the Thin Time-of-flight PET (TT-PET) scanner. The system is designed to read out in the order of 1000 pixel sensors used in the scanner and to provide a reference timing signal…

Instrumentation and Detectors · Physics 2018-12-11 Y. Bandi , Y. Favre , D. Ferrere , D. Forshaw , R. Hanni , D. Hayakawa , G. Iacobucci , P. Lutz , A. Miucci , L. Paolozzi , E. Ripiccini , C. Tognina , P. Valerio , M. Weber

This paper describes the performance of a prototype timing detector, based on 50 micrometer thick Ultra Fast Silicon Detector, as measured in a beam test using a 180 GeV/c momentum pion beam. The dependence of the time precision on the…

After 2001 the upgraded ep collider HERA will provide an about five times higher luminosity for the two experiments H1 and ZEUS. In order to cope with the expected higher event rates the H1 collaboration is building a track based trigger…

High Energy Physics - Experiment · Physics 2014-11-17 A. Baird , E. Elsen , Y. H. Fleming , M. Kolander , S. Kolya , D. Meer , D. Mercer , J. Naumann , P. R. Newman , D. Sankey , A. Schoening , H. -C. Schultz-Coulon , Ch. Wissing

We have developed a new laser-based time calibration system for the MEG II timing counter dedicated to timing measurement of positrons. The detector requires precise timing alignment between $\sim\,$500 scintillation counters. In this…

Instrumentation and Detectors · Physics 2019-05-16 M. Nakao , G. Boca , P. W. Cattaneo , M. De Gerone , F. Gatti , M. Nishimura , W. Ootani , M. Rossella , Y. Uchiyama , M. Usami , K. Yoshida

A Forward Plug Calorimeter (FPC) for the ZEUS detector at HERA has been built as a shashlik lead-scintillator calorimeter with wave length shifter fiber readout. Before installation it was tested and calibrated using the X5 test beam…

‹ Prev 1 2 3 10 Next ›