Related papers: The Design and Performance of the ZEUS Central Tra…
The architecture of the ZEUS Micro Vertex Detector data acquisition system and the implementation of its second level trigger, the ZEUS Global Track Trigger are described. Data from the vertex detectors HELIX read-out chips, corresponding…
The laser alignment system of the ZEUS microvertex detector is described. The detector was installed in 2001 as part of an upgrade programme in preparation for the second phase of electron-proton physics at the HERA collider. The alignment…
In this note we present a mathematical framework for a rigorous approach to a common track fit for trackers located in the inner region of the ZEUS detector. The approach makes use of the Kalman filter and offers a rigorous treatment of…
For the advancement of the understanding of timing systematics in pixelized readout chips and for the benefit of future fast timing detectors to aid 4D tracking technology in the HL-LHC, we have performed detailed studies of the timing…
Time-tagging units and coincidence detectors are used in many scientific research fields. The required timing resolution and number of input channels are varying, but some emerging experiments in the field of quantum optics require up to 32…
Silicon tracking detectors provide excellent spatial resolution, and so can provide excellent momentum resolution for energetic charged particles, even in compact detectors. However, at lower momenta, multiple scattering in the silicon…
The $\upmu$RWELL-PICOSEC detector, which combines a $\upmu$RWELL gaseous amplification structure with a Cherenkov radiator and photocathode, is a novel approach to acheive fast and precise timing in gaseous detectors. With timing precision…
In order to extend the tracking acceptance, to improve the primary and secondary vertex reconstruction and thus enhancing the tagging capabilities for short lived particles, the ZEUS experiment at the HERA Collider at DESY installed a…
The design of a detector system comprised of four silicon sensors bump-bonded to Timepix4 ASICs is described together with its data acquisition system, operational infrastructure, and dedicated software. The spatial and temporal performance…
We propose a novel fast track finding system capable of reconstructing four dimensional particle trajectories in real time using precise space and time information of the hits. Recent developments in silicon pixel detectors achieved 150 ps…
The production of D+- and D0 mesons has been measured with the ZEUS detector at HERA using an integrated luminosity of 133.6 pb-1. The measurements cover the kinematic range 5 < Q^2 < 1000 GeV^2, 0.02 < y < 0.7, 1.5 < p_T^D < 15 GeV and…
We have developed a new laser-based time calibration system for highly segmented scintillator counters like the MEG II pixelated Timing Counter (pTC), consisting of 512-centimeter scale scintillator counters read out by silicon…
Central exclusive processes can be studied in CMS by combining the information of the central detector with the Precision Proton Spectrometer (PPS). PPS detectors, placed symmetrically at more than 200 m from the interaction point, can…
During the HERA luminosity shutdown period 2000/01 the tracking system of the ZEUS experiment has been upgraded with a silicon Micro Vertex Detector (MVD). The barrel part of the detector consists of three layers of single sided silicon…
A new method is employed to measure the neutral current cross section up to Bjorken-x values of one with the ZEUS detector at HERA using an integrated luminosity of 65.1 pb-1 for e+p collisions and 16.7 pb-1 for e-p collisions at…
This paper describes the data acquisition and trigger system of the Thin Time-of-flight PET (TT-PET) scanner. The system is designed to read out in the order of 1000 pixel sensors used in the scanner and to provide a reference timing signal…
This paper describes the performance of a prototype timing detector, based on 50 micrometer thick Ultra Fast Silicon Detector, as measured in a beam test using a 180 GeV/c momentum pion beam. The dependence of the time precision on the…
After 2001 the upgraded ep collider HERA will provide an about five times higher luminosity for the two experiments H1 and ZEUS. In order to cope with the expected higher event rates the H1 collaboration is building a track based trigger…
We have developed a new laser-based time calibration system for the MEG II timing counter dedicated to timing measurement of positrons. The detector requires precise timing alignment between $\sim\,$500 scintillation counters. In this…
A Forward Plug Calorimeter (FPC) for the ZEUS detector at HERA has been built as a shashlik lead-scintillator calorimeter with wave length shifter fiber readout. Before installation it was tested and calibrated using the X5 test beam…