Related papers: X-Ray Multi-Energy Introscopy Systems with New Sem…
Resonant soft X-ray scattering (RSXS) is a powerful technique for probing both spatial and electronic structures within solid-state systems. We present a newly developed RSXS capability at beamline 13-3 of the Stanford Synchrotron Radiation…
Resonant Inelastic X-ray Scattering (RIXS) in the soft x-ray range is an element-specific energy-loss spectroscopy used to probe the electronic and magnetic excitations in strongly correlated solids. In the recent years, RIXS has been…
For ion and neutron spectrometry and imaging applications at a high intensity pulsed laser facility, fast liquid scintillators with very low afterglow are required. Furthermore, neutron imaging with fiber (or liquid-core) capillary arrays…
We proposed a novel method for exploring the intrinsic energy resolution of a liquid scintillator (LAB + 2.5 g/L PPO + 3 mg/L bis-MSB) for approximately 1 MeV electrons. With the help of coincidence detection technology, single-energy…
Some possible applications of the low-angle mid-IR-light scattering technique and some recently developed on its basis methods for non-destructive inspection and investigation of semiconductor materials and structures are discussed in the…
Radiation Detection Systems (RDSs) play a vital role in ensuring public safety across various settings, from nuclear facilities to medical environments. However, these systems are increasingly vulnerable to cyber-attacks such as data…
For identification and 3D-tracking of low-energy electrons a new type of gas-based detector was designed that minimizes scattering and energy loss. The current version of the detector is a combination of a plastic scintillator, serving as a…
Nowadays, the current threat of international terrorism is set to a severe level, demanding worldwide enhanced security. Radioactive materials that could be fashioned into a radiation dispersal device typically emit gamma rays, while…
The scanning mid-IR-laser microscopy was previously demonstrated as an effective tool for characterization of different semiconductor crystals. Now the technique has been successfully applied for the investigation of CZ Si$_x$Ge$_{1-x}$---a…
We are designing an all-scintillator Compton gamma imager for use in security investigations and remediation actions involving radioactive threat material. To satisfy requirements for a rugged and portable instrument, we have chosen solid…
Future HEP experiments at the energy and intensity frontiers present stringent challenges to inorganic scintillators in radiation tolerance, ultrafast time response and cost. This paper reports recent progress in radiation hard, ultrafast,…
A compact gamma-ray detector module was developed and characterized for spectroscopic applications across a wide energy range. The detector comprises a 4x4 array of silicon photomultipliers (SiPMs, Hamamatsu MPPC S13360-3050) coupled with…
Plastic scintillators are a versatile and inexpensive option for particle detection, which is why the largest particle physics experiments, CMS and ATLAS, use them extensively in their calorimeters. One of their challenging aspects,…
For future MeV-scale neutrino experiments, a Cherenkov scintillation detector, CSD, is of particular interest for its capability to reconstruct both energy and direction for charged particles. A type of new target material, slow liquid…
Many experiments in particle physics, in particular in the field of neutrino searches, rely on organic liquid scintillators as target and detection material. The size of these detectors was continously growing in the last decades, up to the…
The M\"ossbauer spectroscopy is presented as an alternative experimental technique to be pursued in the detec-tion of Coherent Elastic{\nu}-Nucleus Scattering (CENNS). The neutrino transferred energy in the neutrino-nucleusinteraction…
Scintillators convert X-ray energy into visible or near-visible photons, enabling applications in high-energy particle detection and X-ray imaging. Increasing scintillator thickness improves X-ray absorption but degrades spatial resolution…
High-energy (>20keV) X-ray photon detection at high quantum yield, high spatial resolution and short response time has long been an important area of study in physics. Scintillation is a prevalent method but limited in various ways.…
A future compact and modular X and gamma-ray spectrometer (XGS) has been designed and a series of prototypes have been developed and tested. The experiment envisages the use of CsI scintillator bars read out at both ends by single-cell 25…
The in-beam tests of two Si pixel type TRACE detectors have been performed at Laboratori Nazionali di Legnaro (Italy). The aim was to investigate the possibility of identifying heavy-ion reactions products with mass A~10 at low kinetic…