Related papers: Improved test of Lorentz Invariance in Electrodyna…
We present the first results from a rotating Michelson-Morley experiment that uses two orthogonally orientated cryogenic sapphire resonator-oscillators operating in whispering gallery modes near 10 GHz. The experiment is used to test for…
We report new results of a test of Lorentz invariance based on the comparison of a cryogenic sapphire microwave resonator and a hydrogen maser. The experimental results are shown together with an extensive analysis of systematic effects.…
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We determine the variation of the oscillator frequency as a function of its…
We report on a test of Lorentz invariance performed by comparing the resonance frequencies of one stationary optical resonator and one continuously rotating on a precision air bearing turntable. Special attention is paid to the control of…
We report on a new test of Lorentz invariance performed by comparing the resonance frequencies of two orthogonal cryogenic optical resonators subject to Earth's rotation over 1 year. For a possible anisotropy of the speed of light c, we…
The cryogenic sapphire oscillator (CSO) at the Paris Observatory has been continuously compared to various Hydrogen Masers since 2001. The early data sets were used to test Local Lorentz Invariance in the Robertson-Mansouri-Sexl (RMS)…
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We determine the variation of the oscillator frequency as a function of its…
A test of Lorentz invariance for electromagnetic waves was performed by comparing the resonance frequencies of two stable optical resonators as a function of orientation in space. The crystalline resonators were operated at 3.4 K in a…
A test of Lorentz invariance for electromagnetic waves was performed by comparing the resonance frequencies of two optical resonators as a function of orientation in space. In terms of the Robertson-Mansouri-Sexl theory, we obtain…
We present an improved laboratory test of Lorentz invariance in electrodynamics by testing the isotropy of the speed of light. Our measurement compares the resonance frequencies of two orthogonal optical resonators that are implemented in a…
A recent experiment by Antonini et. al. [Phys. Rev. A {\bf 71}, 050101R 2005], set new limits on Lorentz violating parameters in the frame-work of the photon sector of the Standard Model Extension (SME), $\tilde{\kappa}_{e-}^{ZZ}$, and the…
We demonstrate that Michelson-Morley tests, which detect direction-dependent anisotropies in the speed of light, can also be used to place limits upon isotropic deviations of the vacuum speed of light from $c$, as described by the photon…
In this work we outline the two most commonly used test theories (RMS and SME) for testing Local Lorentz Invariance (LLI) of the photon. Then we develop the general framework of applying these test theories to resonator experiments with an…
We present a Michelson-Morley type experiment for testing the isotropy of the speed of light in vacuum and matter. The experiment compares the resonance frequency of a monolithic optical sapphire resonator with the resonance frequency of an…
In the recent times, test of Lorentz Invariance has been used as a means to probe theories of physics beyond the standard model. We describe a simple way of utilizing the polarimeters, which are a critical beam instrument at precision and…
We present the first experimental test of Lorentz invariance using the frequency difference between counter-propagating modes in an asymmetric odd-parity optical resonator. This type of test is $\sim10^{4}$ more sensitive to odd-parity and…
We propose and demonstrate a test of Lorentz symmetry based on new, compact, and reliable quartz oscillator technology. Violations of Lorentz invariance in the matter and photon-sector of the standard model extension (SME) generate…
We report Relativity tests based on data from two simultaneous Michelson-Morley experiments, spanning a period of more than one year. Both were actively rotated on turntables. One (in Berlin, Germany) uses optical Fabry-Perot resonators…
For the purpose of searching for Lorentz-invariance violation in the minimal Standard-Model Extension, we perfom a reanalysis of data obtained from the $^{133}\text{Cs}$ fountain clock operating at SYRTE. The previous study led to new…
We report the first operation of a rotating odd-parity Lorentz Invariance test in electrodynamics using a microwave Mach-Zehnder interferometer with permeable material in one arm. The experiment sets a direct bound to $ \kappa_{tr}$ of…