English

Tests of Lorentz Invariance Using a Microwave Resonator: An Update

General Relativity and Quantum Cosmology 2007-05-23 v1 Astrophysics

Abstract

The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We determine the variation of the oscillator frequency as a function of its orientation (Michelson-Morley test) and of its velocity (Kennedy-Thorndike test) with respect to a preferred frame candidate. We constrain the corresponding parameters of the Mansouri and Sexl test theory to δβ+1/23.4×109\delta - \beta + 1/2 \leq 3.4 \times 10^{-9} and βα14.1×107\beta - \alpha - 1 \leq 4.1 \times 10^{-7} which is of the same order as the best previous result for the former and represents a 50 fold improvement for the latter. These results correspond to an improvement of our previously published limits [Wolf P. et al., Phys. Rev. Lett. {\bf 90}, 6, 060402, (2003)] by about a factor 2. We describe the changes of the experiment, and show the new data that lead to that improvement.

Keywords

Cite

@article{arxiv.gr-qc/0306047,
  title  = {Tests of Lorentz Invariance Using a Microwave Resonator: An Update},
  author = {P. Wolf and S. Bize and A. Clairon and A. N. Luiten and G. Santarelli and M. E. Tobar},
  journal= {arXiv preprint arXiv:gr-qc/0306047},
  year   = {2007}
}

Comments

6 pages, 2 figures, to appear in Proc. of the 2003 joint IEEE FCS/EFTF meeting, to appear in Proc. of the 2003 Rencontres de Moriond