English
Related papers

Related papers: Crosstalk Correction in Atomic Force Microscopy

200 papers

A spreadsheet algorithm is given for the atomic force microscope that accounts for non-linear behavior in the deflection of the cantilever and in the photo-diode response. In addition, the data analysis algorithm takes into account…

Soft Condensed Matter · Physics 2013-01-15 Phil Attard

The Transient Fluctuation Theorem is used to calibrate an Atomic Force Microscope by measuring the fluctuations of the work performed by a time dependent force applied between a collo{\"i}dal probe and the surface. From this measure one can…

Mesoscale and Nanoscale Physics · Physics 2020-12-02 Samuel Albert , Aubin Archambault , Artyom Petrosyan , Caroline Crauste-Thibierge , Ludovic Bellon , Sergio Ciliberto

Frequency-modulation atomic force microscopy provides an outstanding precision of the measurement of chemical bonding forces. However, as the cantilever oscillates with an amplitude A that is usually on the order of atomic dimensions or…

Materials Science · Physics 2021-08-13 Ferdinand Huber , Franz J. Giessibl

Image plane beam combination in optical interferometers multiplexes the interference fringes from multiple baselines onto a single detector. The beams of starlight are arranged in a non-redundant pattern at the entrance of the combiner so…

Instrumentation and Methods for Astrophysics · Physics 2022-02-16 Daniel J. Mortimer , David F. Buscher

An ongoing challenge in atomic force microscope (AFM) experiments is the quantitative measurement of cantilever motion. The vast majority of AFMs use the optical beam deflection (OBD) method to infer the deflection of the cantilever. The…

Mesoscale and Nanoscale Physics · Physics 2015-05-22 Aleks Labuda , Roger Proksch

We demonstrate the measurement of laterally induced optical forces using an Atomic Force Microscope (AFM). The lateral electric field distribution between a gold coated AFM probe and a nano-aperture in a gold film is mapped by measuring the…

In this article, we present a deflection measurement setup for Atomic Force Microscopy (AFM). It is based on a quadrature phase differential interferometer: we measure the optical path difference between a laser beam reflecting above the…

Instrumentation and Detectors · Physics 2015-06-16 Pierdomenico Paolino , Felipe A. Aguilar Sandoval , Ludovic Bellon

The quantitative interatomic force measurements open a new pathway to materials characterization, surface science, and chemistry by elucidating the force between 'two' interacting atoms as a function of their separation. Atomic force…

Applied Physics · Physics 2024-06-19 Omur E Dagdeviren

Atomic force microscopy (AFM) is a powerful tool to investigate interaction forces at the micro and nanoscale. Cantilever stiffness, dimensions and geometry of the tip can be chosen according to the requirements of the specific application,…

Applied Physics · Physics 2020-07-31 M. Chighizola , L. Puricelli , L. Bellon , A. Podestà

In atomic force microscopy (AFM), the exchange and alignment of the AFM cantilever with respect to the optical beam and position-sensitive detector (PSD) are often performed manually. This process is tedious and time-consuming and sometimes…

Instrumentation and Detectors · Physics 2016-10-12 Tom Bijnagte , Geerten Kramer , Lukas Kramer , Bert Dekker , Rodolf Herfst , Hamed Sadeghian

Tapping mode atomic force microscopy is a standard technique for inspection and analysis at the nanometer scale. The understanding of the non-linear dynamics of the system due to the tip sample interaction is an important prerequisite for a…

Instrumentation and Detectors · Physics 2007-05-23 Robert W. Stark

Atomic Force Microscopy (AFM) methods utilizing resonant mechanical vibrations of cantilevers in contact with a sample surface have shown sensitivities as high as few picometers for detecting surface displacements. Such a high sensitivity…

Mesoscale and Nanoscale Physics · Physics 2017-02-01 Nina Balke , Stephen Jesse , Ben Carmichael , M. Baris Okatan , Ivan I. Kravchenko , Sergei V. Kalinin , Alexander Tselev

A new method is introduced for calibrating lateral force as measured by an atomic force microscope (AFM), making use of both an interferometric detector and an optical beam detector on the same instrument. The method may be implemented…

Mesoscale and Nanoscale Physics · Physics 2025-03-25 Joel Lefever , Aleksander Labuda , Roger Proksch

We present the design and implementation of a scanning probe microscope, which combines electrically detected magnetic resonance (EDMR) and (photo-)conductive atomic force microscopy ((p)cAFM). The integration of a 3-loop 2-gap X-band…

Torsional harmonic cantilevers allow measurement of time varying tip-sample forces in tapping-mode atomic force microscopy. Accuracy of these force measurements is important for quantitative nanomechanical measurements. Here we demonstrate…

Instrumentation and Detectors · Physics 2008-11-26 Ozgur Sahin

Frequency dependent dynamic behavior in Piezoresponse Force Microscopy (PFM) implemented on a beam-deflection atomic force microscope (AFM) is analyzed using a combination of modeling and experimental measurements. The PFM signal comprises…

Materials Science · Physics 2015-06-25 Stephen Jesse , Arthur P. Baddorf , Sergei V. Kalinin

We present a full analysis of the contrast mechanisms for the detection of ferroelectric domains on all faces of bulk single crystals using scanning force microscopy exemplified on hexagonally poled lithium niobate. The domain contrast can…

Materials Science · Physics 2009-11-13 T. Jungk , A. Hoffmann , E. Soergel

In atomic force microscopy (AFM), the angle relative to the vertical ($\theta_{i}$) that the tip apex of a cantilever moves is determined by the tilt of the probe holder and the geometries of the cantilever and actuated eigenmode $i$. Even…

Mesoscale and Nanoscale Physics · Physics 2017-08-01 Joseph L. Garrett , Lisa J. Krayer , Kevin J. Palm , Jeremy N. Munday

A force measurement technique has been developed that utilizes a clamped fiber optic element both as a cantilever and as a highly sensitive probe of the static and dynamic displacement of a sample that is mounted near its free end. Light…

Condensed Matter · Physics 2009-11-07 R. Budakian , S. J. Putterman

An electro-mechanical setup for the measurement of AC-forces in a low-temperature tunnelling microscope has been developed, which enables extremely high force resolution. The crosstalk of vibrations onto the tunnelling current is used to…

Mesoscale and Nanoscale Physics · Physics 2016-02-17 Markus Herz , Elke Scheer
‹ Prev 1 2 3 10 Next ›