English
Related papers

Related papers: Low-temperature scanning probe microscopy using a …

200 papers

In this work we have used focused electron beam induced deposition of cobalt to functionalize atomic force microscopy Akiyama tips for application in magnetic force microscopy. The grown tips have a content of 90% Co after exposure to…

Mesoscale and Nanoscale Physics · Physics 2017-09-19 Markus Stiller , Jose Barzola-Quiquia , Pablo D. Esquinazi , Soraya Sangiao , Jose M. De Teresa , Jan Meijer , Bernd Abel

Investigation of transport properties is fundamental for characterizing electronic properties and phase transitions. However, most of the transport measurements on conductive layers have been performed at macroscopic scales, and thus the…

Mesoscale and Nanoscale Physics · Physics 2025-06-25 Masayuki Hamada , Masahiro Haze , Junya Okazaki , Yukio Hasegawa

We have used two types of thermometry to study thermal fluctuations in a microcantilever-based system below 1 K. We measured the temperature of a cantilever's macroscopic degree-of-freedom (via the Brownian motion of its lowest flexural…

Other Condensed Matter · Physics 2009-11-13 A. C. Bleszynski Jayich , W. E. Shanks , J. G. E. Harris

We present a new generation of a scanning MicroSQUID microscope operating in an inverted dilution refrigerator. The MicroSQUIDs have a size of 1.21$ \ \mu$m\textsuperscript{2} and a magnetic flux sensitivity of 120 $\mu\Phi_{0} /…

We describe a tip-scan-type high-speed XYZ-nanopositioner designed for scanning ion conductance microscopy (SICM), with a special care being devoted to the way of nanopipette holding. The nanopipette probe is mounted in the center of a…

Instrumentation and Detectors · Physics 2019-12-30 Shinji Watanabe , Toshio Ando

We report local time-resolved thermometry in a silicon nanowire quantum dot device designed to host a linear array of spin qubits. Using two alternative measurement schemes based on rf reflectometry, we are able to probe either local…

An instrument for the simultaneous characterization of thin films by Raman spectroscopy and electronic transport down to 3.7 K has been designed and built. This setup allows for the in-situ preparation of air-sensitive samples, their…

Instrumentation and Detectors · Physics 2024-12-03 Konstantin P. Shchukin , Martin Hell , Alexander Grüneis

A small depression is created in a straight optical fiber taper to form a local probe suitable for studying closely spaced, planar microphotonic devices. The tension of the "dimpled" taper controls the probe-sample interaction length and…

Optics · Physics 2009-11-13 C. P. Michael , M. Borselli , T. J. Johnson , C. Chrystal , O. Painter

We report a scanning superconducting quantum interference device (SQUID) microscope in a cryogen-free dilution refrigerator with a base temperature at the sample stage of at least 30 mK. The microscope is rigidly mounted to the mixing…

Mesoscale and Nanoscale Physics · Physics 2021-09-15 D. Low , G. M. Ferguson , Alexander Jarjour , Brian T. Schaefer , Maja D. Bachmann , Philip J. W. Moll , Katja C. Nowack

We have designed and built a scanning tunneling microscope (STM) setup for operation at millikelvin temperatures in ultra high vacuum. A compact cryostat with an integrated dilution refrigerator has been built, that allows measurements at a…

Instrumentation and Detectors · Physics 2018-12-05 Timofey Balashov , Michael Meyer , Wulf Wulfhekel

We report on the development of a 10B conversion layer optimized for ultra-cold neutron detection with silicon detectors. The efficiency of this layer is high and roughly uniform over a large ultra-cold neutron velocity range. The designed…

A large fraction of quantum science and technology requires low-temperature environments such as those afforded by dilution refrigerators. In these cryogenic environments, accurate thermometry can be difficult to implement, expensive, and…

Applied Physics · Physics 2020-07-07 C. A. Potts , V. A. S. V. Bittencourt , S. Viola Kusminskiy , J. P. Davis

The design and performance of a low-noise, modular cryogenic probe, applicable to a wide range of measurements over a broad range of working frequencies, temperatures, and magnetic fields is presented. The design of the probe facilitates…

Other Condensed Matter · Physics 2022-10-13 Erick Garcia , Calvin Bales , William Patterson , Alexander Zaslavsky , Vesna F. Mitrović

Porous materials provide a large surface to volume ratio, thereby providing a knob to alter fundamental properties in unprecedented ways. In thermal transport, porous nanomaterials can reduce thermal conductivity by not only enhancing…

As a result of suppressed phonon conduction, large improvements of the thermoelectric figure of merit, ZT, have been recently reported for nanostructures compared to the raw materials' ZT values. It has also been suggested that low…

Mesoscale and Nanoscale Physics · Physics 2011-04-11 Neophytos Neophytou , Hans Kosina

Continuous monitoring of voltages ranging from tens to hundreds of kV over environmental conditions, such as temperature, is of great interest in power grid applications. This is typically done via instrument transformers. These…

We report the details of construction and testing of a Quantum Twisting Microscope, a recently developed scanning probe instrument that enables twist angle dependent electronic measurements on layered materials. Our implementation is based…

Mesoscale and Nanoscale Physics · Physics 2026-04-07 Sayanwita Biswas , Ranjani Ramachandran , Patrick Irvin , Jeremy Levy

We introduce a scattering-type scanning near-field infrared microscope (s-SNIM) for the local scale near- field sample analysis and spectroscopy from room (RT) down to liquid helium (LHe) temperatures. The extension of s-SNIM down to T = 5K…

Instrumentation and Detectors · Physics 2018-03-02 D. Lang , J. Döring , T. Nörenberg , A. Butykai , I. Kézsmárki , H. Schneider , S. Winnerl , M. Helm , S. C. Kehr , L. M. Eng

Precise measurement of temperature distribution and thermal behavior in microscopic regions is critical in many research fields. We demonstrate lock-in thermography using nitrogen-vacancy centers in diamond nanoparticles. We successfully…

Applied Physics · Physics 2022-12-16 Kensuke Ogawa , Moeta Tsukamoto , Kento Sasaki , Kensuke Kobayashi

Milli-Kelvin atomic force microscopy (mK-AFM) presents an ongoing experimental challenge due to the intense vibrations in a cryogen-free dilution refrigerator and the low cooling power available at mK temperatures. A viable approach is to…

‹ Prev 1 8 9 10 Next ›