Related papers: AC-Calorimetry at High Pressure and Low Temperatur…
An AC susceptometer operating in the range of 10 Hz to 100 kHz and at room temperature is designed, built, calibrated and used to characterize the magnetic behaviour of coated magnetic nanoparticles. Other weakly magnetic materials (in…
The fourteen kinds of pressure-transmitting media were evaluated by the ruby fluorescence method at room temperature, 77 K using the diamond anvil cell (DAC) up to 10 GPa in order to find appropriate media for use in low temperature…
A wide variety of superconducting oxides are used to test a general model of high pressure induced transition temperature (T c) changes. The T c 's vary from a low of 24 K to a high of 164 K. Although the model is capable of predicting both…
The temperature dependent electrical resistivity of single crystalline SrFe2As2 and BaFe2As2 has been measured in a liquid medium, modified Bridgman anvil cell for pressures in excess of 75 kbar. These data allow for the determination of…
We have extended the range of the high-pressure optical spectroscopy to the far-infrared region keeping the accuracy of ambient-pressure experiments. The newly-developed method offers a powerful tool for the study of pressure-induced phase…
A simple and low cost apparatus has been designed and built to measure the electrical resistivity, ($\rho$), of metal and semiconductors in 300-620 K temperature range. The present design is suitable to do measurement on rectangular bar…
It is claimed that all of the pressure scales of the reported melting curves derived by diamond anvil cell experiments require a correction which takes into account the pressure thermal shift, where vanadium is an illustrative example. The…
Prototypes of MICROMEGAS chambers, using bulk technology and analog readout, with 1x1cm2 readout segmentation have been built and tested. Measurements in Ar/iC4H10 (95/5) and Ar/CO2 (80/20) are reported. The dependency of the prototypes gas…
The complex ac impedance of a bolometer or microcalorimeter detector is easily measured and can be used to determine thermal time constants, thermal resistances, heat capacities, and sensitivities. Accurately extracting this information…
A capacitive displacement system was constructed to measure the electric-field-induced piezoelectric strain in the simple form of either a bulk or thin film. The system can determine an AC displacement of 2 pm precisely by using a lock-in…
In this paper, the calorimetric power measurement method for electron cyclotron resonance heating system on EAST are presented. This method requires measurement of the water flow through the cooling circuits and the input and output water…
We have performed high-pressure, electrical resistivity, and specific heat measurements on CeTe3 single crystals. Two magnetic phases with nonparallel magnetic easy axes were detected in electrical resistivity and specific heat at low…
Using the strong temperature dependent resistance of a normal metal wire in proximity to a superconductor, we have been able to measure the local temperature of electrons heated by flowing a dc current in a metallic wire to within a few…
A new calorimeter for measurements of the AC heat capacity and magnetocaloric effect of small samples in pulsed magnetic fields is discussed for the exploration of thermal and thermodynamic properties at temperatures down to 2 K. We tested…
The evolution of the specific-heat anomaly in the overdoped range of a single crystal of the high-temperature superconductor YBa2Cu3O7 has been studied under influence of pressure up to 10 GPa, using AC calorimetry in a Bridgman-type…
Thermoelectric power sensors can now be used as transfer standards, instead of bolometers, in the microcalorimeter technique. This alternative has the technical advantages to be less sensitive to absolute temperature and not downward…
Capacitance measurement is a useful technique in studying quantum devices, as it directly probes the local particle charging properties, i.e. the system compressibility. Here we report one approach which can measure capacitance from mK to…
We have carried out extensive low-temperature (1.5 to 10 K) measurements of the critical field, $H_c$, for the element Pb up to a pressure of $P=1.2$ GPa. From this data the electronic entropy, specific heat, thermal expansion coefficient…
Barocaloric materials have shown to be promising alternatives to the conventional vapor-compression refrigeration technologies. Nevertheless, barocaloric effect ({\sigma}b-CE) has not been extensively examined for many classes of materials…
We report the realization of an advanced technique for measuring relative length changes $\Delta L/L$ of mm-sized samples under control of temperature ($T$) and helium-gas pressure ($P$). The system, which is an extension of the apparatus…