We have used observations of Cygnus X-1 from the Compton Gamma-Ray Observatory (CGRO) and BeppoSAX to study the variation in the MeV gamma-ray emission between the hard and soft spectral states, using spectra that cover the energy range 20…

In this paper we describe the development and first tests of a neutron spectrometer designed for high flux environments, such as the ones found in fast nuclear reactors. The spectrometer is based on the conversion of neutrons impinging on…

Instrumentation and Detectors · Physics 2015-12-09 M. Osipenko , M. Ripani , G. Ricco , B. Caiffi , F. Pompili , M. Pillon , M. Angelone , G. Verona-Rinati , R. Cardarelli , G. Mila , S. Argiro

We discuss the diagnostics available to study the 5-10 MK plasma in the solar corona, which is key to understanding the heating in the cores of solar active regions. We present several simulated spectra, and show that excellent diagnostics…

Solar and Stellar Astrophysics · Physics 2021-03-11 G. Del Zanna , V. Andretta , P. J. Cargill , A. J. Corso , A. N. Daw , L. Golub , J. A. Klimchuk , H. E. Mason

To constrain the origin of the soft X-ray excess phenomenon seen in many active galactic nuclei, the intensity-correlated spectral analysis, developed by Noda et al. (2011b) for Markarian 509, was applied to wide-band (0.5-45 keV) Suzaku…

Cosmology and Nongalactic Astrophysics · Physics 2015-06-11 Hirofumi Noda , Kazuo Makishima , Kazuhiro Nakazawa , Hideki Uchiyama , Shin'ya Yamada , Soki Sakurai

Transition edge sensor microcalorimeters can measure x-ray and gamma-ray energies with very high energy resolution and high photon-collection efficiency. For this technology to reach its full potential in future x-ray observatories, each…

Instrumentation and Methods for Astrophysics · Physics 2017-02-03 J. W. Fowler , B. K. Alpert , W. B. Doriese , D. A. Fischer , C. Jaye , Y. I. Joe , G. C. O'Neil , D. S. Swetz , J. N. Ullom

This paper presents progress on the development of a cryostat intended to improve upon the low-energy threshold (below 0.5 keV) of p-type point contact germanium gamma-ray spectrometers. Ultra-low energy thresholds are important in the…

Liquid Xenon (LXe) is an excellent material for experiments designed to detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs). A low energy detection threshold is essential for a sensitive WIMP search. The…

Instrumentation and Detectors · Physics 2010-04-06 A. Manzur , A. Curioni , L. Kastens , D. N. McKinsey , K. Ni , T. Wongjirad

The hyperspectral X-ray imaging has been long sought in various fields from material analysis to medical diagnosis. Here we propose a new semiconductor detector structure to realize energy-resolved imaging at potentially low cost. The…

Instrumentation and Detectors · Physics 2019-07-26 Tengfei Yan , Chunlei Yang , Xiaodong Cui

This paper describes a THz transmission spectrometer for the spectral range of 2-65 cm^-1 (100 GHz to 2 THz) with a spectral resolution of at least 1.8 cm^-1 (50 GHz) where the source, sample, and detector are all fully contained in a…

Instrumentation and Detectors · Physics 2009-11-07 P. J. Burke , J. P. Eisenstein , L. N. Pfeiffer , K. W. West

The design and performance of a 1.2 liter liquid xenon chamber equipped with 7 two-inch photomultiplier tubes, with the purpose of studying the scintillation response of xenon to gamma-rays and neutrons, is described. Measurements with…

The performance of the recently commissioned spectrometer PEAXIS for resonant inelastic soft X-ray scattering (RIXS) and X-ray photoelectron spectroscopy (XPS) and its hosting beamline U41-PEAXIS at the BESSY II synchrotron are…

Instrumentation and Detectors · Physics 2019-06-25 Christian Schulz , Klaus Lieutenant , Jie Xiao , Tommy Hofmann , Deniz Wong , Klaus Habicht

The emission of neutrons from heavy ion reactions is an important observable for studying the asymmetric nuclear equation of state and the reaction dynamics. A 20-unit neutron array has been developed and mounted on the compact spectrometer…

We report on the first experimental characterisation of a gamma-ray spectrometer designed to spectrally resolve high-flux photon beams with energies in the GeV range. The spectrometer has been experimentally characterised using a…

We reconstruct spectra of secondary X-rays from a tunable 250-350 MeV laser wakefield electron accelerator from single-shot X-ray depth-energy measurements in a compact (7.5 $\times$ 7.5 $\times$ 15 cm), modular X-ray calorimeter made of…

We present a realisation of high bandwidth instrumentation at cryogenic temperatures and for dilution refrigerator operation that possesses advantages over methods using radio-frequency single electron transistor or transimpedance…

We report the construction and performance of a low temperature, high field scanning tunneling microscope (STM) operating down to 350mK and in magnetic fields up to 9T, with thin film deposition and in-situ cleaving capabilities. The main…

X-ray echo spectroscopy, a counterpart of neutron spin-echo, is being introduced here to overcome limitations in spectral resolution and weak signals of the traditional inelastic x-ray scattering (IXS) probes. An image of a point-like x-ray…

Optics · Physics 2016-02-26 Yuri Shvyd'ko

Protons that are trapped in the Earth's magnetic field are one of the main threats to astronomical X-ray observatories. Soft protons, in the range from tens of keV up to a few MeV, impinging on silicon X-ray detectors can lead to a…

Photonic quantum technologies such as effective quantum communication require room temperature (RT) operating single- or few- photon sensors with high external quantum efficiency (EQE) at 1550 nm wavelength. The leading class of devices in…

Spectral imaging and detection of mid-infrared (mid-IR) wavelengths are emerging as an enabling technology of great technical and scientific interest; primarily because important chemical compounds display unique and strong mid-IR spectral…