Related papers: AMS02 Ecal gamma trigger performance measured at t…
A prototype Scintillator-Tungsten electromagnetic calorimeter (ScECAL) for the ILC detector was tested in 2008 at the Fermilab test beam. Data were collected with electron, pion and muon beams in the energy range 1 to 32GeV combined with…
AMBER (NA66) is a fixed-target facility at the M2 beam line of CERN SPS, which performs worldwide unique research on the internal structure and the excitation spectrum of hadrons. The approved first phase of the experiment focuses on three…
A long Gamma-Ray Burst (GRB) was detected with the instruments on board the INTEGRAL satellite on January 31 2003. Although most of the GRB, which lasted $\sim$150 seconds, occurred during a satellite slew, the automatic software of the…
The upgrade of the ALICE TPC will allow the experiment to cope with the high interaction rates foreseen for the forthcoming Run 3 and Run 4 at the CERN LHC. In this article, we describe the design of new readout chambers and front-end…
The Electromagnetic Mass Analyser (EMMA) is a new vacuum-mode recoil mass spectrometer currently undergoing the final stages of commissioning at the ISAC-II facility of TRIUMF. EMMA employs a symmetric configuration of electrostatic and…
Electromagnetically induced transparency (EIT) and Autler-Townes splitting (ATS) are generally characterized and distinguished by the width of the transparency created in the absorption profile of a weak probe in presence of a strong…
The FEB(front end board) configuration test board is developed aiming at meeting the requirement of testing the new generation ASIC(application-specific integrated circuit) chips and its configuration system for ATLAS NSW(New Small Wheel)…
During LHC Run 2 (2015-2018) the ATLAS Level-1 topological trigger allowed efficient data-taking by the ATLAS experiment at luminosities up to 2.1x10$^{34}$ cm$^{-2}$s$^{-1}$, which exceeds the design value by a factor of two. The system…
We describe methods used to validate data from the Y.T. Lee Array for Microwave Background Anisotropy (AMiBA), an interferometric array designed to measure the Sunyaev-Zel'dovich effect and the anisotropy of the Cosmic Microwave Background…
The E989 Muon $g-2$ experiment at Fermilab aims to measure the anomalous magnetic moment, $a^{}_\mu$, of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession…
The Electron Ion Collider will have two interaction regions that can be instrumented with detectors. The first region will be instrumented as part of the project and needs to be capable of delivering the physics that has been outlined by…
The Inner Tracking System (ITS) is the detector of the ALICE central barrel located closest to the beam axis and it is therefore a key detector for tracking and vertexing performance. Here, the main results from the ITS commissioning with…
Using a dedicated data sample taken in 2018 on the $J/\psi$ peak, we perform a detailed study of the trigger efficiencies of the BESIII detector. The efficiencies are determined from three representative physics processes, namely…
In this paper we describe the performance of a prototype of the High Angle Time Projection Chambers (HA-TPCs) that are being produced for the Near Detector (ND280) upgrade of the T2K experiment. The two HA-TPCs of ND280 will be instrumented…
The spectrometer SPI is one of the main detectors of ESA's INTEGRAL mission. The instrument offers two interesting and valuable capabilities for the detection of the prompt emission of Gamma-ray bursts. Within a field of view of 16 degrees,…
Precision space inertial sensors are imperative to Earth geodesy missions, gravitational wave observations and several fundamental physics experiments in space. In these missions, the residual acceleration noise of the test mass(TM) caused…
A prototype Secondary-electron Emission Monitor (SEM) was installed in the 8 GeV proton transport line for the MiniBooNE experiment at Fermilab. The SEM is a segmented grid made with 5 um Ti foils, intended for use in the 120 GeV NuMI beam…
The AEgIS experiment at CERN recently decided to adopt a control system solution based on the Sinara/ARTIQ open hardware and software infrastructure. This decision meant to depart from the previously used paradigm of custom-made electronics…
The electromagnetic calorimeter (ECAL) of the AMS-02 experiment is a 3-dimensional sampling calorimeter, made of lead and scintillating fibers. The detector allows for a high granularity, with 18 samplings in the longitudinal direction, and…
We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with…