English
Related papers

Related papers: Robust determination of optical path difference: f…

200 papers

We study both the wave-like behavior and particle-like behavior in a general Mach-Zehnder interferometer with its asymmetric beam splitter. A error-free measurement in the detector is used to extract the which-path information. The fringe…

Quantum Physics · Physics 2017-04-26 Yanjun Liu , Jing Lu , and Lan Zhou

Fourier imaging is an indirect imaging method which records the diffraction pattern of the object scene coherently in the focal plane of the imaging system and reconstructs the image using computational resources. The spatial resolution,…

Optics · Physics 2023-06-05 Hui Yuan , Alvydas Lisauskas , Mark D. Thomson , Hartmut G. Roskos

A magnetic field gradient applied to an atom interferometer induces a $M$-dependent phase shift which results in a series of decays and revivals of the fringe visibility. Using our lithium atom interferometer based on Bragg laser…

Quantum Physics · Physics 2016-08-16 Marion Jacquey , Alain Miffre , Matthias Büchner , Gérard Trénec , Jacques Vigué

Infrared space interferometers can surpass the spatial resolution limitations of single-dish space telescopes. However, stellar interferometers from space have not been realized because of technical difficulties. Two beams coming from…

Instrumentation and Methods for Astrophysics · Physics 2022-01-20 Taro Matsuo , Satoshi Ikari , Hirotaka Kondo , Sho Ishiwata , Shinichi Nakasuka , Tomoyasu Yamamuro

Fourier transform spectroscopy (FTS) has been widely used as an analytical tool for many applications in science and engineering. In this paper, we describe the operation principle and practical implementation of an FTS prototype. First,…

Instrumentation and Detectors · Physics 2023-02-02 Sohrab Sheikh-Sofla , Mohammad Neshat

SPICA-FT is part of the CHARA/SPICA instrument which combines a visible 6T fibered instrument (SPICAVIS) with a H-band 6T fringe sensor. SPICA-FT is a pairwise ABCD integrated optics combiner. The chip is installed in the MIRC-X instrument.…

Any frequency selective device with an ongoing drift will cause observed spectra to be variously and simultaneously scaled in proportion to their source distances. The reason is that detectors after the drifting selection will integrate…

General Physics · Physics 2008-12-05 V. Guruprasad

Direction of arrival (DOA) estimation is mostly performed using specialized arrays that have carefully designed receiver spacing and layouts to match the operating frequency range. In contrast, radio interferometric arrays are designed to…

Instrumentation and Methods for Astrophysics · Physics 2025-12-23 Sarod Yatawatta

The Planet Formation Imager (PFI) is a project for a very large optical interferometer intended to obtain images of the planet formation process at scales as small as the Hill sphere of giant exoplanets. Its main science instruments will…

Instrumentation and Methods for Astrophysics · Physics 2016-10-27 Romain G. Petrov , Abdelkarim Boskri , Thami Elhalkouj , John Monnier , Michael Ireland , Stefan Kraus

We present the first demonstration of an inertially sensitive atomic interferometer based on a continuous, rather than pulsed, atomic beam at sub-Doppler temperatures in three dimensions. We demonstrate 30\% fringe contrast in continuous,…

Atomic Physics · Physics 2022-02-24 J. M. Kwolek , A. T. Black

Many protocols for long distance quantum communication require interferometric phase stability over long distances of optical fibers. In this paper we investigate the phase noise in long optical fibers both in laboratory environment and in…

Quantum Physics · Physics 2008-08-22 Jiří Minář , Hugues de Riedmatten , Christoph Simon , Hugo Zbinden , Nicolas Gisin

We used an atom interferometer for atom optical shop testing of lenses for atomic de Broglie waves. We measured focal lengths and spherical aberrations of electrostatic lenses in three independent ways based on contrast data, phase data, or…

I present in this paper a method to calibrate data obtained from optical and infrared interferometers. I show that correlated noises and errors need to be taken into account for a very good estimate of individual error bars but also when…

Astrophysics · Physics 2009-11-07 G. Perrin

The Large Binocular Telescope Interferometer uses a near-infrared camera to measure the optical path length variations between the two AO-corrected apertures and provide high-angular resolution observations for all its science channels…

Instrumentation and Methods for Astrophysics · Physics 2016-12-14 D. Defrère , P. Hinz , E. Downey , M. Böhm , W. C. Danchi , O. Durney , S. Ertel , J. M. Hill , W. F. Hoffmann , B. Mennesson , R. Millan-Gabet , M. Montoya , J. -U. Pott , A. Skemer , E. Spalding , J. Stone , A. Vaz

Atomic interferometers measure forces and acceleration with exceptional precision. The conventional approach to atomic interferometry is to launch an atomic cloud into a ballistic trajectory and perform the wave-packet splitting in momentum…

Quantum Physics · Physics 2024-02-23 Jonathan Nemirovsky , Rafi Weill , Ilan Meltzer , Yoav Sagi

Purpose. Intraoperative Optical Coherence Tomography (iOCT) is an increasingly available imaging technique for ophthalmic microsurgery that provides high-resolution cross-sectional information of the surgical scene. We propose to build on…

Computer Vision and Pattern Recognition · Computer Science 2018-02-20 Jakob Weiss , Nicola Rieke , Mohammad Ali Nasseri , Mathias Maier , Abouzar Eslami , Nassir Navab

Spatial phase-referencing in dual-field optical interferometry is reconsidered. Our analysis is based on the 2-sample variance of the differential phase between target and reference star. We show that averaging over time of the atmospheric…

Astrophysics · Physics 2009-11-07 Gerard Daigne , Jean-Francois Lestrade

A novel method capable of delivering relative optical path length metrology with nanometer precision is demonstrated. Unlike conventional dual-wavelength metrology which employs heterodyne detection, the method developed in this work…

Instrumentation and Methods for Astrophysics · Physics 2015-06-15 Yitping Kok , Michael J. Ireland , J. Gordon Robertson , Peter G. Tuthill , Benjamin A. Warrington , William J. Tango

Construction of silicon neutron interferometers requires a perfect crystal silicon ingot (5 cm to 30 cm long) be machined such that Bragg diffracting "blades" protrude from a common base. Leaving the interferometer blades connected to the…

A polarization-multiplexed, dual-beam setup is proposed to expand the field of view for a swept source optical coherence tomography angiography (OCTA) system. This method used a Wollaston prism to split sample path light into two…

Medical Physics · Physics 2017-10-30 Jianlong Yang , Rahul Chandwani , Rui Zhao , Zhuo Wang , Yali Jia , David Huang , Gangjun Liu