Related papers: A charge transfer inefficiency correction model fo…
The X-ray telescope on board the Swift satellite for gamma-ray burst astronomy has been exposed to the radiation of the space environment since launch in November 2004. Radiation causes damage to the detector, with the generation of dark…
We report the radiation hardness of a p-channel CCD developed for the X-ray CCD camera onboard the XRISM satellite. This CCD has basically the same characteristics as the one used in the previous Hitomi satellite, but newly employs a notch…
Modern silicon tracking detectors based on hybrid or fully integrated CMOS technology are continuing to push to thinner sensors. The ionization energy loss fluctuation in very thin silicon sensors significantly deviates from the Landau…
The Compton Spectrometer and Imager is an upcoming NASA space telescope in the MeV range. COSI's primary science goals include precisely mapping nuclear line and positron annihilation emission in the Milky Way galaxy through Compton…
We characterize the astrometric distortion at the edges of thick, fully-depleted CCDs in the lab using a bench-top simulation of LSST observing. By illuminating an array of forty thousand pinholes (30mu m diameter) at the object plane of a…
The measurement of charged particle spectra in heavy ion collisions is a way to study properties of hot and dense matter created in these interactions. The centrality dependence of the spectral shape is an important tool to understand the…
Hard X-ray photons with energies in the range of hundreds of keV typically undergo Compton scattering when they are incident on a detector. In this process, an incident photon deposits a fraction of its energy at the point of incidence and…
Much of the baryonic matter in the Universe, including the most active and luminous sources, are best studied in the X-ray band. Key advances in X-ray optics and detectors have paved the way for the Advanced X-ray Imaging Satellite (AXIS),…
We present measurements of electron and hole trapping in three COSI germanium cross-strip detectors. By characterizing the relative charge collection efficiency (CCE) as a function of interaction depth, we show that intrinsic trapping of…
A high-precision charge measurement can be achieved by the area integration of a digitized quasi-Gaussian signal after the signal passes through the shaper and analog-to-digital converter (ADC). The charge measurement contains an error due…
We discuss the measurement of the charged-current elastic scattering process $e^-p\rightarrow\nu_e n$ at the Electron-Ion Collider (EIC). This process provides sensitivity to the poorly constrained axial form factor of the nucleon, which…
The Soft X-ray Imager (SXI) is an imaging spectrometer using charge-coupled devices (CCDs) aboard the Hitomi X-ray observatory. The SXI sensor has four CCDs with an imaging area size of $31~{\rm mm} \times 31~{\rm mm}$ arranged in a $2…
Edge-TCT and charge collection measurements with passive test structures made in LFoundry 150 nm CMOS process on p-type substrate with initial resistivity of over 3 k$\Omega$cm are presented. Measurements were made before and after…
In coded aperture snapshot spectral imaging (CASSI), the captured measurement entangles spatial and spectral information, posing a severely ill-posed inverse problem for hyperspectral images (HSIs) reconstruction. Moreover, the captured…
Thick fully depleted CCDs, while enabling wide spectral response, also present challenges in understanding the systematic errors due to 3D charge transport. This 2014 Workshop on Precision Astronomy with Fully Depleted CCDs covered progress…
Coded Aperture Imaging (CAI) has been proposed as an alternative collimation technique in nuclear imaging. To maximize spatial resolution small pinholes in the coded aperture mask are required. However, a high-resolution detector is needed…
AIMS: Clinical radiographic imaging is seated upon the principle of differential keV photon transmission through an object. At clinical x-ray energies the scattering of photons causes signal noise and is utilized solely for transmission…
We report on the design and performance of a mixed-signal application specific integrated circuit (ASIC) dedicated to avalanche photodiodes (APDs) in order to detect hard X-ray emissions in a wide energy band onboard the International Space…
In this paper a detailed simulation of irradiated pixel sensors was used to investigate the effects of radiation damage on charge sharing and position determination. The simulation implements a model of radiation damage by including two…
High-contrast imaging relies on advanced coronagraphs and adaptive optics (AO) to attenuate the starlight. However, residual aberrations, especially non-common path aberrations between the AO channel and the coronagraph channel, limit the…