Related papers: Characterizing IMARAD CZT Detectors with Time Reso…
We report on a large active area (15x15mm2), high channel density (470 pixels/mm2), self-triggering CMOS analog chip that we have developed as pixelized charge collecting electrode of a Micropattern Gas Detector. This device, which…
Low-pressure gaseous TPCs are well suited detectors to correlate the directions of nuclear recoils to the galactic Dark Matter (DM) halo. Indeed, in addition to providing a measure of the energy deposition due to the elastic scattering of a…
The Speedster-EXD is a new 64x64 pixel, 40 $\mu$m pixel pitch, 100 $\mu$m depletion depth hybrid CMOS X-ray detector (HCD) with the capability of reading out only those pixels containing event charge, thus enabling fast effective frame…
Using industrial standard 0.35{\mu}m CMOS Integrated Circuit process, we realized a highly pixelated sensor that directly collects charge via metal nodes placed on the top of each pixel and forms two dimensional images of charge cloud…
We describe initial results of our program to develop and test Cd-Zn-Te (CZT) detectors with a pixellated array readout. Our primary interest is in the development of relatively thick CZT detectors for use in astrophysical coded aperture…
The geometry of electrodes is one of the most important factors in determining the performance of orthogonal-strip detectors. The aim of this work is to study the performance of a 5 mm thick cross-strip CdZnTe detector with different…
We present an updated design of the 220 GHz microwave kinetic inductance detector (MKID) pixel for SPT-3G+, the next-generation camera for the South Pole Telescope. We show results of the dark testing of a 63-pixel array with mean inductor…
Time over dynamic threshold (TODT) method, proposed in our previous work, has been successfully used for nuclear pulse charge measurement in PET detectors. It has advantages of strict linearity, large dynamic range, and better energy…
We developed a 2-mm-thick CdTe double-sided strip detector (CdTe-DSD) with a 250 um strip pitch, which has high spatial resolution with a uniform large imaging area of 10 cm$^2$ and high energy resolution with high detection efficiency in…
Low-Gain Avalanche Diode (LGAD) sensor is one of candidate sensors for the tracker at future hadron collider experiments. To use this sensor as a tracking detector, AC-LGAD sensor is being developed which has both timing and spatial…
The M\"ONCH hybrid pixel detector, with a 25 \textmu m pixel pitch and fast charge-integrating readout, has demonstrated subpixel resolution capabilities for X-ray imaging and deep learning-based electron localization in electron…
Charge collection properties of depleted CMOS pixel detector prototypes produced on p-type substrate of 2 k$\Omega$cm initial resistivity (by LFoundry 150 nm process) were studied using Edge-TCT method before and after neutron irradiation.…
We design and experimentally characterize a balanced homodyne detector optimized for high-repetition-rate (100 MHz) pulsed optical sources. Unlike conventional transimpedance-amplifier architectures, which suffer from nonlinearities and…
3D silicon detectors are characterized by cylindrical electrodes perpendicular to the surface and penetrating into the bulk material in contrast to standard Si detectors with planar electrodes on its top and bottom. This geometry renders…
The development of CdZnTe detectors with an orthogpnal coplanar anode structure has important implications for future astrophysical instrumentation. As electron-only devices, like pixel detectors, coplanar anode strip detectors can be…
Compact multi-channel radiation detectors rely on low noise front-end application specific integrated circuits (ASICs) to achieve high spectral resolution. Here, a new ASIC developed to readout virtual Frisch-grid cadmium zinc telluride…
We have investigated charge sharing among the anode strips of a CdZnTe (CZT) detector using a 30 micrometer collimated gamma-ray beam. We compared the laboratory measurements with the predictions from our modeling of the charge transport…
We develop a photon energy measurement scheme for single photon counting Microwave Kinetic Inductance Detectors (MKIDs) that uses principal component analysis (PCA) to measure the energy of an incident photon from the signal ("photon…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…
We present a novel single-photon detector based on a vacuum tube incorporating a photocathode, a microchannel plate (MCP), and a Timepix4 CMOS ASIC functioning as a pixelated anode. Designed to handle photon rates up to 1 billion per second…