English
Related papers

Related papers: PET-Adapter: Test-Time Domain Adaptation for Full …

200 papers

PET suffers from a low signal-to-noise ratio. Meanwhile, the k-space data acquisition process in MRI is time-consuming by PET-MRI systems. We aim to accelerate MRI and improve PET image quality. This paper proposed a novel joint…

Computer Vision and Pattern Recognition · Computer Science 2024-08-23 Taofeng Xie , Zhuoxu Cui , Congcong Liu , Chen Luo , Huayu Wang , Yuanzhi Zhang , Xuemei Wang , Yihang Zhou , Qiyu Jin , Guoqing Chen , Dong Liang , Haifeng Wang

Score-based generative models (SGMs) have recently shown promising results for image reconstruction on simulated positron emission tomography (PET) datasets. In this work we have developed and implemented practical methodology for 3D image…

Positron Emission Tomography (PET) is an important clinical imaging tool but inevitably introduces radiation hazards to patients and healthcare providers. Reducing the tracer injection dose and eliminating the CT acquisition for attenuation…

Computer Vision and Pattern Recognition · Computer Science 2024-06-18 Tianqi Chen , Jun Hou , Yinchi Zhou , Huidong Xie , Xiongchao Chen , Qiong Liu , Xueqi Guo , Menghua Xia , James S. Duncan , Chi Liu , Bo Zhou

Uncompressed clinical data from modern positron emission tomography (PET) scanners are very large, exceeding 350 million data points (projection bins). The last decades have seen tremendous advancements in mathematical imaging tools many of…

Medical Physics · Physics 2020-01-08 Matthias J. Ehrhardt , Pawel Markiewicz , Carola-Bibiane Schönlieb

Potential radioactive hazards in full-dose positron emission tomography (PET) imaging remain a concern, whereas the quality of low-dose images is never desirable for clinical use. So it is of great interest to translate low-dose PET images…

Image and Video Processing · Electrical Eng. & Systems 2023-06-06 Yang Zhou , Zhiwen Yang , Hui Zhang , Eric I-Chao Chang , Yubo Fan , Yan Xu

Generating positron emission tomography (PET) images from computed tomography (CT) scans via deep learning offers a promising pathway to reduce radiation exposure and costs associated with PET imaging, improving patient care and…

Image and Video Processing · Electrical Eng. & Systems 2026-02-16 Valerio Guarrasi , Francesco Di Feola , Rebecca Restivo , Lorenzo Tronchin , Paolo Soda

To obtain high-quality Positron emission tomography (PET) images while minimizing radiation exposure, numerous methods have been proposed to reconstruct standard-dose PET (SPET) images from the corresponding low-dose PET (LPET) images.…

Image and Video Processing · Electrical Eng. & Systems 2024-04-10 Jiaqi Cui , Yan Wang , Lu Wen , Pinxian Zeng , Xi Wu , Jiliu Zhou , Dinggang Shen

Convolutional neural networks (CNNs) have recently achieved remarkable performance in positron emission tomography (PET) image reconstruction. In particular, CNN-based direct PET image reconstruction, which directly generates the…

Medical Physics · Physics 2024-10-28 Fumio Hashimoto , Kibo Ote

Positron emission tomography (PET) is widely used for clinical diagnosis. As PET suffers from low resolution and high noise, numerous efforts try to incorporate anatomical priors into PET image reconstruction, especially with the…

Medical Physics · Physics 2019-12-17 Nuobei Xie , Kuang Gong , Ning Guo , Zhixin Qin , Zhifang Wu , Huafeng Liu , Quanzheng Li

Accurate quantification in positron emission tomography (PET) is essential for accurate diagnostic results and effective treatment tracking. A major issue encountered in PET imaging is attenuation. Attenuation refers to the diminution of…

To acquire high-quality positron emission tomography (PET) images while reducing the radiation tracer dose, numerous efforts have been devoted to reconstructing standard-dose PET (SPET) images from low-dose PET (LPET). However, the success…

Image and Video Processing · Electrical Eng. & Systems 2024-07-31 Jiaqi Cui , Pinxian Zeng , Yuanyuan Xu , Xi Wu , Jiliu Zhou , Yan Wang

Deep learning models in medical imaging often encounter challenges when adapting to new clinical settings unseen during training. Test-time adaptation offers a promising approach to optimize models for these unseen domains, yet its…

Machine Learning · Computer Science 2024-10-28 Sameer Ambekar , Julia A. Schnabel , Cosmin I. Bercea

The ability to synthesise Computed Tomography images - commonly known as pseudo CT, or pCT - from MRI input data is commonly assessed using an intensity-wise similarity, such as an L2-norm between the ground truth CT and the pCT. However,…

Image and Video Processing · Electrical Eng. & Systems 2020-04-15 Kerstin Kläser , Thomas Varsavsky , Pawel Markiewicz , Tom Vercauteren , David Atkinson , Kris Thielemans , Brian Hutton , M Jorge Cardoso , Sebastien Ourselin

Positron Emission Tomography (PET) is a powerful molecular imaging tool that plays a crucial role in modern medical diagnostics by visualizing radio-tracer distribution to reveal physiological processes. Accurate organ segmentation from PET…

Computer Vision and Pattern Recognition · Computer Science 2026-03-13 Yichi Zhang , Le Xue , Wenbo Zhang , Lanlan Li , Yuchen Liu , Chen Jiang , Yuan Cheng , Yuan Qi

Positron Emission Tomography (PET) is an imaging technique which can be used to investigate chemical changes in human biological processes such as cancer development or neurochemical reactions. Most dynamic PET scans are currently analyzed…

Applications · Statistics 2014-11-11 Ci-Ren Jiang , John A D Aston , Jane-Ling Wang

Radiation exposure in positron emission tomography (PET) imaging limits its usage in the studies of radiation-sensitive populations, e.g., pregnant women, children, and adults that require longitudinal imaging. Reducing the PET radiotracer…

Image and Video Processing · Electrical Eng. & Systems 2021-07-22 Viswanath P. Sudarshan , Uddeshya Upadhyay , Gary F. Egan , Zhaolin Chen , Suyash P. Awate

Training computer-vision related algorithms on medical images for disease diagnosis or image segmentation is difficult due to the lack of training data, labeled samples, and privacy concerns. For this reason, a robust generative method to…

Image and Video Processing · Electrical Eng. & Systems 2021-11-04 Robert V Bergen , Jean-Francois Rajotte , Fereshteh Yousefirizi , Ivan S Klyuzhin , Arman Rahmim , Raymond T. Ng

Anatomically guided PET reconstruction using MRI information has been shown to have the potential to improve PET image quality. However, these improvements are limited to PET scans with paired MRI information. In this work we employed a…

Image and Video Processing · Electrical Eng. & Systems 2024-03-28 Weijie Gan , Huidong Xie , Carl von Gall , Günther Platsch , Michael T. Jurkiewicz , Andrea Andrade , Udunna C. Anazodo , Ulugbek S. Kamilov , Hongyu An , Jorge Cabello

Purpose: Neural network image reconstruction directly from measurement data is a relatively new field of research, that until now has been limited to producing small single-slice images (e.g., 1x128x128). This paper proposes a novel and…

Image and Video Processing · Electrical Eng. & Systems 2020-02-13 William Whiteley , Wing K. Luk , Jens Gregor

Positron range (PR) limits spatial resolution and quantitative accuracy in PET imaging, particularly for high-energy positron-emitting radionuclides like 68Ga. We propose a deep learning method using 3D residual encoder-decoder…