English
Related papers

Related papers: A Constrained Formulation for Simultaneous Line Pa…

200 papers

With the continued deployment of synchronized Phasor Measurement Units (PMUs), high sample rate data are rapidly increasing the real time observability of power systems. Prior research has shown that the statistics of these data can provide…

Systems and Control · Computer Science 2018-05-11 Samuel Chevalier , Paul D. H. Hines

Phasor measurement units (PMUs) are integrated to the transmission networks under the smart grid umbrella. The observability of PMUs is geographically limited due to their high cost in integration. The measurements of PMUs can be…

Systems and Control · Computer Science 2017-06-12 HyungSeon Oh

The use of phasor angle measurements provided by phasor measurement units (PMUs) in fault detection is regarded as a promising method in identifying locations of power line outages. However, communication errors or system malfunctions may…

Systems and Control · Computer Science 2016-11-17 Wen-Tai Li , Chao-Kai Wen , Jung-Chieh Chen , Kai-Kit Wong , Jen-Hao Teng , Chau Yuen

In this paper, a phasor measurement unit (PMU)-based wide-area damping control method is proposed to damp the interarea oscillations that threaten the modern power system stability and security. Utilizing the synchronized PMU data, the…

Systems and Control · Electrical Eng. & Systems 2021-08-04 Ilias Zenelis , Xiaozhe Wang

Accurate spatiotemporal calibration is a prerequisite for multisensor fusion. However, sensors are typically asynchronous, and there is no overlap between the fields of view of cameras and LiDARs, posing challenges for intrinsic and…

Robotics · Computer Science 2025-01-07 Yuezhang Lv , Yunzhou Zhang , Chao Lu , Jiajun Zhu , Song Wu

In this paper, we study the placement of Phasor Measurement Units (PMU) for enhancing hybrid state estimation via the traditional Gauss-Newton method, which uses measurements from both PMU devices and Supervisory Control and Data…

Optimization and Control · Mathematics 2016-11-15 Xiao Li , Anna Scaglione , Tsung-Hui Chang

In this paper, phasor measurement unit (PMU) placement for power grid state estimation under different degrees of observability is studied. Observability degree is the depth of the buses' reachability by the placed PMUs and thus constitutes…

Systems and Control · Computer Science 2018-06-08 Y. Shi , H. D. Tuan , A. A. Nasir , T. Q. Duong , H. V. Poor

This paper presents a machine learning-accelerated optimization framework for RF power amplifier design that reduces simulation requirements by 65% while maintaining $\pm0.4$ dBm accuracy for the majority of the modes. The proposed method…

Machine Learning · Computer Science 2025-07-21 Abhishek Sriram , Neal Tuffy

Phasor Measurement Units (PMUs) are essential measuring devices for monitoring, control and protection of power systems. The objective of the optimal PMU placement (OPP) problem is to minimize the number of PMUs and select the bus locations…

Optimization and Control · Mathematics 2015-08-25 Nikolaos Theodorakatos , Nikolaos Manousakis , George Korres

The problem of imbalance detection in a three-phase power system using a phasor measurement unit (PMU) is considered. A general model for the zero, positive, and negative sequences from a PMU measurement at off-nominal frequencies is…

Applications · Statistics 2016-11-18 Tirza Routtenberg , Yao Xie , Rebecca M. Willett , Lang Tong

Increased adoption and deployment of phasor measurement units (PMU) has provided valuable fine-grained data over the grid. Analysis over these data can provide insight into the health of the grid, thereby improving control over operations.…

Databases · Computer Science 2016-05-26 Ben McCamish , Rich Meier , Jordan Landford , Robert Bass , Eduardo Cotilla-Sanchez , David Chiu

Power flow calculation methods have been developed in decades using power injections and Newton-Raphson method. The nonlinear characteristics of the power flow to the bus voltage require Jacobian matrix reformation and refactorization in…

Signal Processing · Electrical Eng. & Systems 2019-02-25 Renchang Dai , Xiang Zhang , Junjie Shi , Guangyi Liu , Chen Yuan , Zhiwei Wang

Phasor Measurement Unit (PMU) technology is increasingly used for real-time monitoring applications, especially line outage detection and identification (D&I) in the power system. Current outage D&I schemes either assume a full PMU…

Systems and Control · Electrical Eng. & Systems 2020-09-08 Xiaozhou Yang , Nan Chen , Chao Zhai

Calibration of sensors is a fundamental step to validate their operation. This can be a demanding task, as it relies on acquiring a detailed modelling of the device, aggravated by its possible dependence upon multiple parameters. Machine…

Inverter-based resources (IBRs) exhibit fast transient dynamics during network disturbances, which often cannot be properly captured by phasor and SCADA measurements. This shortcoming has recently been addressed with the advent of waveform…

Signal Processing · Electrical Eng. & Systems 2026-01-27 Shivanshu Tripathi , Hossein Mohsenzadeh Yazdi , Maziar Raissi , Hamed Mohsenian-Rad

Installation of phasor measurement units (PMUs) in a number of substations in the power grid can help assess a set of its values and parameters, in particular those related to the dynamics when disturbances occur in the system. Inertia…

Systems and Control · Electrical Eng. & Systems 2021-04-19 Mohammadali Hayerikhiyavi , Aleksandar Dimitrovski

The statistical characterization of the measurement errors of a phasor measurement unit (PMU) is currently receiving considerable interest in the power systems community. This paper focuses on the characteristics of the errors in magnitude…

Systems and Control · Electrical Eng. & Systems 2021-03-18 Demetra Salls , Jairo Ramírez Torres , Antos Cheeramban Varghese , John Patterson , Anamitra Pal

Phasor Measurement Units (PMUs) are placed at strategic vertices in an electrical power network to monitor the flow of power. Determining the minimum number and optimal placement of PMUs is modeled by the graph theoretic process called…

Combinatorics · Mathematics 2026-05-27 Johnathan Koch , Beth Bjorkman

The Phasor measurement unit (PMU) measurements are mandatory to monitor the power system's voltage stability margin in an online manner. Monitoring is key to the secure operation of the grid. Traditionally, online monitoring of voltage…

Systems and Control · Electrical Eng. & Systems 2024-12-20 Kishan Prudhvi Guddanti , Amarsagar Reddy Ramapuram Matavalam , Yang Weng

An important step in building a quantum computer is calibrating experimentally implemented quantum gates to produce operations that are close to ideal unitaries. The calibration step involves estimating the systematic errors in gates and…

Quantum Physics · Physics 2021-10-22 Shelby Kimmel , Guang Hao Low , Theodore J. Yoder