Related papers: Advances in photocathode development for PICOSEC M…
The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of…
A new timing detector measuring ~50 MeV/c positrons is under development for the MEG II experiment, aiming at a time resolution $\sigma_t \sim 30~\mathrm{ps}$. The resolution is expected to be achieved by measuring each positron time with…
A monolithic silicon pixel detector prototype has been produced in the SiGe BiCMOS SG13G2 130 nm node technology by IHP. The ASIC contains a matrix of hexagonal pixels with pitch of approximately 100 $\mu$m. Three analog pixels were…
Cerenkov technology is often the optimal choice for particle identification in high energy particle collision applications. Typically, the most challenging regime is at high pseudorapidity (forward) where particle identification must…
In this paper, we present the design and preliminary performance evaluation of a new heavy-ion detector for direct measurements of heavy {\Lambda} hypernuclei lifetime. The detector employs the previously developed 10 picosecond resolution…
Working gas components significantly impact the performance of gaseous detectors. A fast-timing Micromegas detector with two-stage amplification is prone to notable deterioration of uniformity when scaled up. This paper presents a…
The proof-of-concept prototype of the Picosecond Avalanche Detector, a multi-PN junction monolithic silicon detector with continuous gain layer deep in the sensor depleted region, was tested with a beam of 180 GeV pions at the CERN SPS. The…
The ALICE Collaboration is proposing a completely new apparatus, ALICE 3, for the LHC Run 5 and beyond. A key subsystem for charged particle identification will be a Ring-Imaging Cherenkov (RICH) detector consisting of an aerogel radiator…
The development of new detectors based on Silicon Carbide (SiC) is currently a topic of interest within the scientific community. The significant features of SiC make it highly promising for detecting charged particles, neutrons, and…
We present the development of a single-photon detector and the connected read-out electronics. This `hybrid' detector is based on a vacuum tube, transmission photocathode, microchannel plate and a pixelated CMOS read-out anode encapsulating…
Experiments at the future Electron Ion Collider require excellent hadron identification in a broad momentum range, in harsh conditions. A RICH capable to fulfill the PID requirements of the EIC could use MPGD-based photon detectors with…
Microchannel plate photodetectors provide both picosecond time resolution and sub-millimeter position resolution, making them attractive photosensors for particle identification detectors of a future U.S. Electron Ion Collider. We have…
With the tenfold luminosity increase envisaged at the HL-LHC, the background (photons, neutrons, ...) and the event pile-up probability are expected to increase in proportion in the different experiments, especially in the forward regions…
We report on the detection of single photons with {\lambda} = 8 {\mu}m using a superconducting hot-electron microbolometer. The sensing element is a titanium transition-edge sensor with a volume ~ 0.1 {\mu}m^3 fabricated on a silicon…
Application of Micromegas for sampling calorimetry puts specific constraints on the design and performance of this gaseous detector. In particular, uniform and linear response, low noise and stability against high ionisation density…
Micromegas is presently in use by many experiments providing enhanced performance when used in high particle environment. Compared with other solid-state detectors or conventional gas counters Micromegas is robust and radiation hard. Recent…
This article presents the timing performance of materials with fast light emission, tested as Minimum Ionizing Particle detectors using 150 GeV hadron beams in Monte Carlo simulations and at the CERN SPS North Area. Pixels of cross-section…
A simulation model is developed to train Artificial Neural Networks (ANN), for precise timing of PICOSEC Micromegas detector signals. The aim is to develop fast, online timing algorithms as well as minimising the information to be saved…
For the High-Luminosity (HL-LHC) phase, the upgrade of the Compact Muon Solenoid (CMS) experiment at CERN will include a novel MIP Timing Detector (MTD). The central part of MTD, the barrel timing layer (BTL), is designed to provide a…
The barrel section of the novel MIP Timing Detector (MTD) will be constructed as part of the upgrade of the CMS experiment to provide a time resolution for single charged tracks in the range of $30-60$ ps using LYSO:Ce crystal arrays read…