Related papers: Performance Evaluation of Straw Tubes with Muon Be…

200 papers

The Muon $g-2$ Experiment at Fermilab uses a gaseous straw tracking detector to make detailed measurements of the stored muon beam profile, which are essential for the experiment to achieve its uncertainty goals. Positrons from muon decays…

We propose a high-precision, fast, robust and cost-effective muon detector concept for an FCC-ee experiment. This design combines precision drift tubes with fast plastic scintillator strips to enable both spatial and timing measurements.…

The article considers a prototype module with sensitive dimensions of 2 x 0.5 m2 based on 2 m long straw tubes which preserves its geometrical dimensions up to the pressure of 4 bar independently of the ambient temperature and humidity. The…

Instrumentation and Detectors · Physics 2012-10-23 V. Peshekhonov , K. Davkov , V. Myalkovskiy , N. Russakovich , I. Zhukov

Straw tube detectors are single wire proportional counters that are widely used as a tracking device. We have carried out R$\&$D with a straw tube detector prototype. The motivation of this work is to study the stability of the performance…

Instrumentation and Detectors · Physics 2021-04-07 S. Roy , S. Jaiswal , S. Chatterjee , A. Sen , S. Das , S. K. Ghosh , S. Raha , V. M. Lysan , G. D. Kekelidze , V. V. Myalkovsky , S. Biswas

Prototypes of newly developed boron-coated straw (BCS) detectors have been tested in the thermal and cold neutron energy ranges. Their neutron detection performance has been benchmarked against the industry standard (detector tubes filled…

Instrumentation and Detectors · Physics 2020-01-29 Georg Ehlers , Athanasios Athanasiades , Liang Sun , Christopher S. Martin , Murari Regmi , Jeffrey L. Lacy

The COMET experiment focuses on searching for the direct conversion of a muon into an electron on an aluminum nucleus without emitting a neutrino (so-called $\mu\rightarrow e$ conversion). This conversion violates the lepton flavor…

Instrumentation and Detectors · Physics 2024-12-10 N. Tsverava , G. Adamov , D. Chokheli , H. Nishiguchi , T. Toriashvili , Z. Tsamalaidze

The Fermilab Muon $g-2$ experiment is currently preparing for its fourth data-taking period (Run-4). The experiment-wide effort on the analysis of Run-1 data is nearing completion, with the announcement of the first result expected in the…

Instrumentation and Detectors · Physics 2020-12-08 Gleb Lukicov

The charged particles are tracked in the high energy physics detectors to provide the information of their properties. One of the tracking detector is straw tube detector that has been used by many experiments. The motivation behind the…

Instrumentation and Detectors · Physics 2025-06-10 R. Kanishka

The coordinate detectors based on straw tubes provide a high accuracy of the radial coordinate measurement using the drift time and a small amount of matter in the way of the measured particles. However, the measurement of the coordinate…

A cylindrical GEM tracker is under construction in order to replace and improve the inner tracking system of the BESIII experiment. Tests with planar chamber prototypes were carried out on the H4 beam line of SPS (CERN) with muons of 150…

The $g-2$ experiment successfully completed its second data taking period (Run-2) between March and July 2019, with the analysis of Run-1 and Run-2 data currently proceeding. The final goal of the experiment is to determine the muon…

Instrumentation and Detectors · Physics 2019-10-02 Gleb Lukicov

The resolution and efficiency of a precision drift-tube chamber for the ATLAS muon spectrometer with final read-out electronics was tested at the Gamma Irradiation Facility at CERN in a 100 GeV muon beam and at photon irradiation rates of…

Instrumentation and Detectors · Physics 2016-04-06 M. Deile , J. Dubbert , S. Horvat , O. Kortner , H. Kroha , A. Manz , S. Mohrdieck-Moeck , F. Rauscher , R. Richter , A. Staude , W. Stiller

We study the light output, light collection efficiency and signal timing of a variety of organic scintillators that are being considered for the upgrade of the hadronic calorimeter of the CMS detector. The experimental data are collected at…

Instrumentation and Detectors · Physics 2018-02-14 HCAL collaboration

A muon tracking system consisting of four 9cm x 10cm sized bulk Micromegas detectors with 128um amplification-gap and two 10cm x 10cm triple GEM detectors is foreseen for high-precision tracking of 140GeV muons at the H8 beamline at CERN…

Instrumentation and Detectors · Physics 2015-06-03 Jonathan Bortfeldt , Otmar Biebel , David Heereman , Ralf Hertenberger

New developments in Thin Gap Chambers (TGC) detectors to provide fast trigger and high precision muon tracking under sLHC conditions are presented. The modified detectors are shown to stand a high total irradiation dose equivalent to 6…

Basic R & D have been carried out with one small straw tube detector prototype with premixed gas of Ar+CO2 in 70:30 and 90:10 ratio. The gain and the energy resolution are measured with Fe55 X-ray source. Effect of temperature and pressure…

Instrumentation and Detectors · Physics 2017-09-26 S. Roy , N. Nandi , R. P. Adak , S. Biswas , S. Das , S. K. Ghosh , S. K. Prasad , S. Raha

Operating conditions and challenging demands of present and future accelerator experiments result in new requirements on detector systems. There are many ongoing activities aimed to develop new technologies and to improve the properties of…

This article presents the results of a study of the longitudinal spatial resolution of 2 m long straw tubes by means of the direct timing method (DTM). The feasibility of achieving a coordinate resolution (r.m.s.) better than 2 cm over full…

Instrumentation and Detectors · Physics 2015-06-12 A. M. Makankin , V. V. Myalkovskiy , V. D. Peshekhonov , S. Ritt , S. E. Vasilyev

The muon detectors of the experiments at the Large Hadron Collider (LHC) have to cope with unprecedentedly high neutron and gamma ray background rates. In the forward regions of the muon spectrometer of the ATLAS detector, for instance,…

Instrumentation and Detectors · Physics 2016-10-04 B. Bittner , J. Dubbert , O. Kortner , H. Kroha , F. Legger , R. Richter , O. Biebel , A. Engl , R. Hertenberger , F. Rauscher

A tracking detector system has been constructed with an innovative approach to the classical multi-wire proportional chamber concept, using contemporary technologies. The detectors, covering an area of 0.58 square meters each, are optimized…

Instrumentation and Detectors · Physics 2016-08-30 Dezső Varga , Gábor Nyitrai , Gergő Hamar , László Oláh