Related papers: Initial Performance of the TUCAN Magnetically Shie…
Magnetic field uniformity is of the utmost importance in experiments to measure the electric dipole moment of the neutron. A general parametrization of the magnetic field in terms of harmonic polynomial modes is proposed, going beyond the…
Experiments dedicated to the measurement of the electric dipole moment of the neutron require outstanding control of the magnetic field uniformity. The neutron electric dipole moment (nEDM) experiment at the Paul Scherrer Institute uses a…
An array of sixteen laser-pumped scalar Cs magnetometers was part of the neutron electric dipole moment (nEDM) experiment taking data at the Paul Scherrer Institute in 2015 and 2016. It was deployed to measure the gradients of the…
Ultracold neutrons (UCN) are free neutrons that can be stored in experimental setups for several minutes. Some of the most important properties of the neutron, such as its tiny permanent electric dipole moment and its beta decay lifetime,…
The neutron electric dipole moment experiment at the Spallation Neutron Source (nEDM@SNS experiment) proposes to measure the nEDM using the spin-dependent capture cross section of neutrons on $^3$He. The critical dressing mode of this…
The experiment on the direct detection of antineutrino-electron scattering with an artificial tritium source allows to lower the present-day laboratory limit for the neutrino magnetic moment by two orders of magnitude. The experiment brings…
The n2EDM experiment at the Paul Scherrer Institute aims to conduct a high-sensitivity search for the electric dipole moment of the neutron. Magnetic stability and control are achieved through a combination of passive shielding, provided by…
We report a new measurement of the neutron electric dipole moment with the PNPI EDM spectrometer using the ultracold neutron source PF2 at the research reactor of the ILL. Its first results can be interpreted as a limit on the neutron EDM…
The TITAN facility at TRIUMF has recently initiated a program of performing decay spectroscopy measurements in an electron-beam ion-trap (EBIT). The unique environment of the EBIT provides backing-free storage of the radioactive ions, while…
We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in…
The milliQan Collaboration has proposed to search for millicharged particles by looking for very weakly ionizing tracks in a detector installed in a cavern near the CMS experiment at the LHC. We note that another form of exotica can also…
nEDMSF aims to measure the neutron electric dipole moment ($d_n$) with unprecedented precision. In this paper we explore the experiment's sensitivity when operating with an implementation of the critical dressing method in which the angle…
Recently strong electric fields (up to 10^9 V/cm) have been discovered, which affect the neutrons moving in noncentrosymmetric crystals. Such fields allow new polarization phenomena in neutron diffraction and optics and provide, for…
The MUNU detector has been designed to study antineutrino-electron elastic scattering at low energy. The central tracking detector is a 1 m3 Time Projection Chamber surrounded by an anti-Compton detector. In this paper the results from…
The current best upper limit for electron electric dipole moment (EDM), $|d_e|<1.1\times10^{-29}\,$e$\cdot$cm ($90$% confidence), was set by the ACME collaboration in 2018. The ACME experiment uses a spin-precession measurement in a cold…
We propose an original test of Lorentz invariance in the interaction between a particle spin and an electromagnetic field and report on a first measurement using ultracold neutrons. We used a high sensitivity neutron electric dipole moment…
A common concern in high-precision neutron electric dipole moment (nEDM) experiments is that of magnetic field stability. For static fields, this problem can be mitigated through the use of a superconducting holding field coil, which when…
Perfect-crystal neutron interferometry has been a useful tool in measuring nuclear-interactions, probing fundamental physics, and exploring quantum phenomenon. Historically, neutron interferometry experiments have been carried out at room…
We compare the expected effects of so-called gravitationally enhanced depolarization of ultracold neutrons to measurements carried out in a spin-precession chamber exposed to a variety of vertical magnetic-field gradients. In particular, we…
A significant functional upgrade is planned for the Mega Ampere Spherical Tokamak (MAST) device, located at Culham in the UK, including the implementation of a notably greater neutral beam injection power. This upgrade will cause the…