English
Related papers

Related papers: Design and Implementation of a Multi-Sensor DAQ Sy…

200 papers

The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis…

Instrumentation and Detectors · Physics 2024-08-20 J. Aalbers , D. S. Akerib , A. K. Al Musalhi , F. Alder , C. S. Amarasinghe , A. Ames , T. J. Anderson , N. Angelides , H. M. Araújo , J. E. Armstrong , M. Arthurs , A. Baker , S. Balashov , J. Bang , E. E. Barillier , J. W. Bargemann , K. Beattie , T. Benson , A. Bhatti , A. Biekert , T. P. Biesiadzinski , H. J. Birch , E. Bishop , G. M. Blockinger , B. Boxer , C. A. J. Brew , P. Brás , J. H. Buckley , S. Burdin , M. Buuck , M. C. Carmona-Benitez , M. Carter , A. Chawla , H. Chen , J. J. Cherwinka , Y. T. Chin , N. I. Chott , M. V. Converse , A. Cottle , G. Cox , D. Curran , C. E. Dahl , A. David , J. Delgaudio , S. Dey , L. de Viveiros , L. Di Felice , T. Dimino , C. Ding , J. E. Y. Dobson , E. Druszkiewicz , S. R. Eriksen , A. Fan , N. M. Fearon , N. Fieldhouse , S. Fiorucci , H. Flaecher , E. D. Fraser , T. M. A. Fruth , R. J. Gaitskell , A. Geffre , R. Gelfand , J. Genovesi , C. Ghag , R. Gibbons , S. Gokhale , J. Green , M. G. D. van der Grinten , J. J. Haiston , C. R. Hall , S. Han , E. Hartigan-O'Connor , S. J. Haselschwardt , M. A. Hernandez , S. A. Hertel , G. Heuermann , G. J. Homenides , M. Horn , D. Q. Huang , D. Hunt , E. Jacquet , R. S. James , J. Johnson , A. C. Kaboth , A. C. Kamaha , M. Kannichankandy , D. Khaitan , A. Khazov , I. Khurana , J. Kim , Y. D. Kim , J. Kingston , R. Kirk , D. Kodroff , L. Korley , E. V. Korolkova , M. Koyuncu , H. Kraus , S. Kravitz , L. Kreczko , V. A. Kudryavtsev , D. S. Leonard , K. T. Lesko , C. Levy , J. Lin , A. Lindote , R. Linehan , W. H. Lippincott , C. Loniewski , M. I. Lopes , W. Lorenzon , C. Lu , S. Luitz , P. A. Majewski , A. Manalaysay , R. L. Mannino , C. Maupin , M. E. McCarthy , G. McDowell , D. N. McKinsey , J. McLaughlin , J. B. Mclaughlin , R. McMonigle , E. H. Miller , E. Mizrachi , A. Monte , M. E. Monzani , M. Moongweluwan , J. D. Morales Mendoza , E. Morrison , B. J. Mount , M. Murdy , A. St. J. Murphy , A. Naylor , H. N. Nelson , F. Neves , A. Nguyen , J. A. Nikoleyczik , H. Oh , I. Olcina , M. A. Olevitch , K. C. Oliver-Mallory , J. Orpwood , K. J. Palladino , J. Palmer , N. J. Pannifer , N. Parveen , S. J. Patton , B. Penning , G. Pereira , E. Perry , T. Pershing , A. Piepke , Y. Qie , J. Reichenbacher , C. A. Rhyne , Q. Riffard , G. R. C. Rischbieter , H. S. Riyat , R. Rosero , T. Rushton , D. Rynders , D. Santone , R. Sarkis , A. B. M. R. Sazzad , R. W. Schnee , S. Shaw , T. Shutt , J. J. Silk , C. Silva , G. Sinev , J. Siniscalco , W. Skulski , R. Smith , V. N. Solovov , P. Sorensen , J. Soria , I. Stancu , A. Stevens , K. Stifter , B. Suerfu , T. J. Sumner , M. Szydagis , W. C. Taylor , D. R. Tiedt , M. Timalsina , Z. Tong , D. R. Tovey , J. Tranter , M. Trask , M. Tripathi , D. R. Tronstad , A. Vacheret , A. C. Vaitkus , J. Vaitkus , O. Valentino , V. Velan , A. Wang , J. J. Wang , Y. Wang , J. R. Watson , R. C. Webb , L. Weeldreyer , T. J. Whitis , M. Williams , W. J. Wisniewski , F. L. H. Wolfs , J. D. Wolfs , S. Woodford , D. Woodward , C. J. Wright , Q. Xia , X. Xiang , J. Xu , M. Yeh , J. Yin

The data acquisition system (DAQ) for a highly granular analogue hadron calorimeter (AHCAL) for the future International Linear Collider is presented. The developed DAQ chain has several stages of aggregation and scales up to 8 million…

Instrumentation and Detectors · Physics 2019-08-13 Jiri Kvasnicka

Multiple advantages had been identified with the integration of data acquisition into any existing system configuration and implementation. Using data acquisition as a support into a monitoring system has not only improved its overall…

Systems and Control · Electrical Eng. & Systems 2025-07-15 Chito A. Petilla

We report a mixed-signal data acquisition (DAQ) system for optically detected magnetic resonance (ODMR) of solid-state spins. This system is designed and implemented based on a Field-Programmable-Gate-Array (FPGA) chip assisted with…

Quantum Physics · Physics 2022-01-19 Feifei Zhou , Shupei Song , Yuxuan Deng , Ting Zhang , Bing Chen , Nanyang Xu

High energy physics experiments in KEK/Japan rush into over KHz trigger stage. Thus, we need a successor of the data acquisition(DAQ) system that replaces the CAMAC or FASTBUS systems. To meet these needs, we have developed a DAQ system…

This paper discusses the present data acquisition system (DAQ) of the COMPASS experiment at CERN and presents development of a new DAQ. The new DAQ must preserve present data format and be able to communicate with FPGA cards. Parts of the…

Instrumentation and Detectors · Physics 2015-06-25 M. Bodlak , V. Frolov , V. Jary , S. Huber , I. Konorov , D. Levit , J. Novy , S. Paul , R. Salac , M. Virius

The Real-Time Systems Engineering Department of the Scientific Computing Division at Fermilab is developing a flexible, scalable, and powerful data-acquisition (DAQ) toolkit which serves the needs of experiments from bench-top hardware…

The XENONnT detector uses the latest and largest liquid xenon-based time projection chamber (TPC) operated by the XENON Collaboration, aimed at detecting Weakly Interacting Massive Particles and conducting other rare event searches. The…

Instrumentation and Detectors · Physics 2023-08-09 E. Aprile , J. Aalbers , K. Abe , F. Agostini , S. Ahmed Maouloud , L. Althueser , B. Andrieu , E. Angelino , J. R. Angevaare , V. C. Antochi , D. Antón Martin , F. Arneodo , L. Baudis , A. L. Baxter , L. Bellagamba , R. Biondi , A. Bismark , E. J. Brookes , A. Brown , S. Bruenner , G. Bruno , R. Budnik , T. K. Bui , C. Cai , J. M. R. Cardoso , D. Cichon , A. P. Cimental Chavez , D. Coderre , A. P. Colijn , J. Conrad , J. J. Cuenca-García , J. P. Cussonneau , V. D'Andrea , M. P. Decowski , P. Di Gangi , S. Di Pede , S. Diglio , K. Eitel , A. Elykov , S. Farrell , A. D. Ferella , C. Ferrari , H. Fischer , M. Flierman , W. Fulgione , C. Fuselli , P. Gaemers , R. Gaior , A. Gallo Rosso , M. Galloway , F. Gao , R. Glade-Beucke , L. Grandi , J. Grigat , M. Guida , R. Hammann , A. Higuera , C. Hils , L. Hoetzsch , N. F. Hood , J. Howlett , M. Iacovacci , Y. Itow , J. Jakob , F. Joerg , A. Joy , N. Kato , M. Kara , P. Kavrigin , S. Kazama , M. Kobayashi , G. Koltman , A. Kopec , F. Kuger , H. Landsman , R. F. Lang , L. Levinson , I. Li , S. Li , S. Liang , S. Lindemann , M. Lindner , K. Liu , J. Loizeau , F. Lombardi , J. Long , J. A. M. Lopes , Y. Ma , C. Macolino , J. Mahlstedt , A. Mancuso , L. Manenti , F. Marignetti , T. Marrodán Undagoitia , K. Martens , J. Masbou , D. Masson , E. Masson , S. Mastroianni , M. Messina , K. Miuchi , K. Mizukoshi , A. Molinario , S. Moriyama , K. Morå , Y. Mosbacher , M. Murra , J. Müller , K. Ni , U. Oberlack , B. Paetsch , J. Palacio , R. Peres , C. Peters , J. Pienaar , M. Pierre , V. Pizzella , G. Plante , J. Qi , J. Qin , D. Ramírez García , A. Rocchetti , L. Sanchez , P. Sanchez-Lucas , J. M. F. dos Santos , I. Sarnoff , G. Sartorelli , J. Schreiner , D. Schulte , P. Schulte , H. Schulze Eißing , M. Schumann , L. Scotto Lavina , M. Selvi , F. Semeria , P. Shagin , S. Shi , E. Shockley , M. Silva , H. Simgen , A. Takeda , P. -L. Tan , A. Terliuk , D. Thers , F. Toschi , G. Trinchero , C. Tunnell , F. Tönnies , K. Valerius , G. Volta , C. Weinheimer , M. Weiss , D. Wenz , C. Wittweg , T. Wolf , D. Xu , Z. Xu , M. Yamashita , L. Yang , J. Ye , L. Yuan , G. Zavattini , S. Zerbo , M. Zhong , T. Zhu

We have developed a novel data acquisition system for measuring tracking parameters of a silicon detector in a particle beam. The system is based on a commercial Analog-to-Digital VME module and a PC Linux based Data Acquisition System.…

The POEMMA-Balloon with Radio (PBR) mission incorporates an advanced data processing system (DP) to enable the detection and characterization of ultra-high-energy cosmic rays and astrophysical neutrinos. The data acquisition (DAQ) system…

The complexity and cost of managing high-performance computing infrastructures are on the rise. Automating management and repair through predictive models to minimize human interventions is an attempt to increase system availability and…

Distributed, Parallel, and Cluster Computing · Computer Science 2015-09-08 Alina Sîrbu , Ozalp Babaoglu

Submersible Buoy (SB) is an important apparatus capable of long-term, fixed-point, continuous and multi-directional measurement of acoustic signals and hydrological environment monitoring in the harsh marine environment, providing important…

Instrumentation and Detectors · Physics 2018-06-28 Zhilei Zhang , Peng Miao , Houbing Liu , Kun Hu , Feng Li , Ge Jin

We developed a SpaceWire-based data acquisition (DAQ) system for the FOXSI-4 and FOXSI-5 sounding rocket experiments, which aim to observe solar flares with high sensitivity and dynamic range using direct X-ray focusing optics. The FOXSI-4…

The energy available in Micro Grid (MG) that is powered by solar energy is tightly related to the weather conditions in the moment of generation. Very short-term forecast of solar irradiance provides the MG with the capability of…

Image and Video Processing · Electrical Eng. & Systems 2020-12-08 Guillermo Terrén-Serrano , Manel Martínez-Ramón

This paper presents the design and implementation of the front-end electronics and the data acquisition (DAQ) system for readout of multi-wire drift chambers (MWDC). Apart of the conventional drift time measurement the system delivers the…

Instrumentation and Detectors · Physics 2015-12-09 K. Lojek , D. Rozpedzik , K. Bodek , M. Perkowski , N. Severijns

J-PARC E16 is an experiment to examine the origin of hadron mass through a systematic measurement of spectral changes of vector mesons in nuclei. The measurement of $e^{+}e^{-}$ pairs from the decay of vector mesons will provide the…

Common and unique features of nuclear physics measurements are examined. Such analysis with respect to existing hardware and software platforms and standards allows to algorithmize the DAQ, monitoring and processing tasks. A universal…

Instrumentation and Detectors · Physics 2015-08-07 Zdenek Hons

Purpose: The Taishan Antineutrino Observatory (TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO), also known as JUNO-TAO. Located close to one of the reactors of the Taishan Nuclear Power Plant, TAO will…

Instrumentation and Detectors · Physics 2024-09-10 Shuihan Zhang , Chao Chen , Xiaolu Ji , Fei Li , Yu Peng , Fabrizio Petrucci , Yinhui Wu , Zezhong Yu , Tingxuan Zeng , Kejun Zhu

Microwave reflectometry is a non-intrusive plasma diagnostic tool which is widely applied in many fusion devices. In 2014, the microwave reflectometry on Experimental Advanced Superconducting Tokamak (EAST) had been upgraded to measure…

Instrumentation and Detectors · Physics 2016-11-17 Fei Wen , Tao Zhang , Shoubiao Zhang , Defeng Kong , Yuming Wang , Xiang Han , Hao Qu , Xiang Gao

Modern DAQ systems typically use the FPGA-based PCIe cards to concentrate and deliver the data to a computer used as an entry node of the data processing network. This paper presents a QEMU-based methodology for the co-development of the…

Instrumentation and Detectors · Physics 2023-09-28 Wojciech M. Zabołotny