Related papers: Semiautomatic dimensional screening of plastic sci…
We report the first clear observation of neutron/gamma-ray pulse-shape sensitivity of a fully-instrumented 8 $\times$ 8 array of plastic scintillator segments coupled to two 5 cm $\times$ 5 cm 64-channel SiPM arrays as part of a study of…
Pixelated plastic scintillator arrays can serve as high efficiency and high resolution neutron imaging detectors. Manufacturing these arrays is intensive in both time and labor. This work presents a fabrication method based on additive…
Muon tomography is a non-destructive imaging technique that uses cosmic-ray muons to probe dense materials. Bar scintillator and scintillating fiber detectors equipped with one-dimensional SiPM arrays offer compact, high-resolution…
An aboveground 60-kg reactor-antineutrino detector prototype, comprised of a 2-dimensional array of 36 $^{6}$Li-doped pulse shape sensitive plastic scintillator bars, is described. Each bar is 50~cm long with a square cross section of…
The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204…
Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…
A novel scintillator detector, the SuperFGD, has been selected as the main neutrino target for an upgrade of the T2K experiment ND280 near detector. The detector design will allow nearly 4{\pi} coverage for neutrino interactions at the near…
A high-performance Scintillator Ion Beam Monitor (SIBM) provides diagnostics across a range of isotopes, energies, and intensities employing a machine-vision camera with two novel scintillator targets movable into/out of the beam without…
Scintillating fibre detectors combine sub-mm resolution particle tracking, precise measurements of the particle stopping power and sub-ns time resolution. Typically, fibres are read out with silicon photomultipliers (SiPM). Hence, if fibres…
Current clinical PET systems utilize detectors where the scintillator typically contains single elements of 3 - 6 mm width and about 20 mm height. While providing good TOF performance, this design limits the spatial resolution and causes…
The Atomic Spectroscopy and Collisions Using Slow Antiprotons (ASACUSA) experiment at the Antiproton Decelerator (AD) facility of CERN constructed segmented scintillators to detect and track the charged pions which emerge from antiproton…
A 760 $\times$ 760 $\times$ 30 mm$^3$ plastic scintillation detector viewed by photomultiplier tubes (PMTs) from four corners has been developed, and the detector has been tested with cosmic rays and $\gamma$ rays. A position-independent…
The growing complexity of particle detectors makes their construction and quality control a new challenge. We present studies that explore the use of deep learning-based computer vision techniques to perform quality checks of detector…
A novel beam profiler based on microstructured scintillation resin is presented. The detector consists of a bundle of waveguides, with an active area of 30 x 30 mm$^2$ and a pitch of 400 $\mu$m, obtained by molding a scintillating resin…
A plastic scintillator bar with dimensions 300 cm x 2.5 cm x 11 cm was exposed to a focused muon beam to study its light yield and timing characteristics as a function of position and angle of incidence. The scintillating light was read out…
In this study an array of eight 6 mm x 6 mm area SiPMs was coupled to the end of a long plastic scintillator counter which was exposed to a 2.5 GeV/c muon beam at the CERN PS. Timing characteristics of bars with dimensions 150 cm x 6 cm x 1…
Cosmic-ray muons, owing to their high penetration power and abundance, have been widely employed as a natural probe in experimental particle physics. We developed a meter-scale cosmic-ray muon telescope, consisting of two parallel…
Preclinical research and organ-dedicated applications require high-resolution positron emission tomography (PET) detectors to visualize small structures and understand biological processes at a finer level of detail. Current commercial…
Tomographic imaging techniques using the Coulomb scattering of cosmic-ray muons are increasingly being exploited for the non-destructive assay of shielded containers in a wide range of applications. One such application is the…
We present a characterization of a small (9-liter) and mobile 0.1% 6Li-doped pulse-shape-sensitive plastic scintillator antineutrino detector called SANDD (Segmented AntiNeutrino Directional Detector), constructed for the purpose of…