Related papers: Maximum-Likelihood--Based Position Decoding of Las…
The response of a position-sensitive Li-glass scintillator detector being developed for thermal-neutron detection with 6 mm position resolution has been investigated using collimated beams of thermal neutrons. The detector was moved…
In this study, we propose a fast implementation of a Maximum Likelihood Positioning (MLP) algorithm to estimate the energy and identify the active scintillator pixel in staggered layer scintillation detectors for PET. The staggered layer…
We report on the scintillation characterization of a 1 cm^3 CsI(Tl) crystal coupled to a 6 x 6 mm^2 SiPM read out with a custom transimpedance amplifier at cryogenic temperatures. The crystal was prepared with optical-grade surfaces and…
We report on the spatial response characterization of large LaCl$_{3}$(Ce) monolithic crystals optically coupled to 8$\times$8 pixel silicon photomultiplier (SiPM) sensors. A systematic study has been carried out for 511 keV $\gamma$-rays…
The response of a position-sensitive Li-glass based scintillation detector to focused beams of 2.5 MeV protons and deuterons has been investigated. The beams were scanned across the detector in 0.5 mm horizontal and vertical steps…
A high sensitivity Cardiac SPECT system using curved crystals with pinhole collimation was proposed previously (Dey, IEEE TNS 2012, Bhusal et al, Med. Phys. 2019). Here, we hypothesize that a high curvature hemi-ellipsoid detector results…
The linear response of CsI(Tl) crystals to $\gamma$-rays plays a crucial role in their calibration, as any deviation from linearity can introduce systematic errors not negligible in the measurement of $\gamma$ energy spectra, particularly…
We developed a beam telescope system comprising five layers of 300-$\mu$m-thick INTPIX4NA monolithic pixel sensors with each pixel size of 17 $\mu$m square. The sensors were fabricated using silicon-on-insulator (SOI) technology. The…
The aim of this study was to optimize the design of a monolithic LGSO scintillation crystal and micro parallel-hole collimator for the development of a small-animal single photon emission computed tomography (SPECT) system with compact…
Pixelated silicon detectors are state-of-the-art technology to achieve precise tracking and vertexing at collider experiments, designed to accurately measure the hit position of incoming particles in high rate and radiation environments.…
A tightly focused pulsed laser can locally modify the crystal structure inside the bulk of a scintillator. The result is incorporation of so-called optical barriers with a refractive index (RI) different from that of the crystal bulk, that…
Precision pose detection is increasingly demanded in fields such as personal fabrication, Virtual Reality (VR), and robotics due to its critical role in ensuring accurate positioning information. However, conventional vision-based systems…
Single-pixel imaging (SPI) has offered an unprecedented technique for capturing a targeted scenes without requiring either raster-scanned systems or muti-pixel detectors. However, in the current research, there are rare study reports about…
We investigate five different models to reconstruct the 3D $\gamma$-ray hit coordinates in five large \lacls monolithic crystals optically coupled to pixelated silicon photomultipliers. These scintillators have a base surface of 50 $\times$…
Over the last decade one of the most significant technological advances made in the field of radiation detectors for nuclear medicine was the development of Silicon Photomultipler (SiPM) sensors. At present a only small number of SiPM based…
Current clinical PET systems utilize detectors where the scintillator typically contains single elements of 3 - 6 mm width and about 20 mm height. While providing good TOF performance, this design limits the spatial resolution and causes…
Correlation plenoptic imaging (CPI) is a light-field imaging technique employing intensity correlation measurements to simultaneously detect the spatial distribution and the propagation direction of light. Compared to standard methods, in…
In this work, image analysis techniques used in astrophysics to detect low-contrast signals have been adapted in the processing of Computed Tomography (CT) images, combining Centroidal Voronoi Tessellation (CVT) and machine learning…
Coincidence time resolution (CTR) in time-of-flight positron emission tomography (TOF-PET) has significantly improved with advancements in scintillators, photodetectors, and readout electronics. Achieving a CTR of 100 ps remains challenging…
Future electron-positron ($\ee$) colliders, operating as Higgs factories or Z factories, promise unprecedented precision electroweak measurements that are vital to testing the Standard Model (SM) and exploring physics beyond it. Here we…