English
Related papers

Related papers: Beyond One-Thousandth Energy Resolution with an Al…

200 papers

Transition-edge sensors (TESs) as microcalorimeters offer high resolving power, owning to their sharp response and low operating temperature. In the hard X-ray regime and above, the demand for high quantum-efficiency requires the use of…

For cosmic particle spectroscopy on the International Space Station the AMS experiment will be equipped with a Transition Radiation Detector (TRD) to improve particle identification. The TRD has 20 layers of fleece radiator with Xe/CO2…

We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250{\mu}m squared, AuBi…

We report on the design, commissioning, and initial measurements of a Transition-edge Sensor (TES) x-ray spectrometer for the Electron Beam Ion Trap (EBIT) at the National Institute of Standards and Technology (NIST). Over the past few…

We investigate the crosstalk between Transition-Edge Sensor (TES) pixels in a prototype 24-pixel hard X-ray array fabricated at the Advanced Photon Source, Argonne National Laboratory. Analysis shows thermal cross talk, possibly associated…

Instrumentation and Detectors · Physics 2025-02-19 Panthita Triamkitsawat , Tejas Guruswamy , Orlando Quaranta , Lisa Gades , Umeshkumar Patel , Antonino Miceli

A 57Fe nucleus in the solar core could emit a 14.4-keV monochromatic axion through the M1 transition if a hypothetical elementary particle, axion, exists to solve the strong CP problem. Transition edge sensor (TES) X-ray microcalorimeters…

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at $\sim$10 mK, are usually…

The sensitivity of a low-noise superconducting transition edge sensor (TES) is determined by the thermal conductance of the support structure that connects the active elements of the device to the heat bath. Low-noise devices require…

Mesoscale and Nanoscale Physics · Physics 2018-11-14 Emily A. Williams , Stafford Withington , Christopher N. Thomas , David J. Goldie , Djelal Osman

The determination of the neutrino mass is an open issue in modern particle physics and astrophysics. The direct mass measurement is the only theory-unrelated experimental tool capable to probe such quantity. The HOLMES experiment aims to…

If a hypothetical elementary particle called an axion exists, to solve the strong CP problem, a 57Fe nucleus in the solar core could emit a 14.4-keV monochromatic axion through the M1 transition. If such axions are once more transformed…

Instrumentation and Methods for Astrophysics · Physics 2023-04-20 Yuta Yagi , Tasuku Hayashi , Keita Tanaka , Rikuta Miyagawa , Ryo Ota , Noriko Y. Yamasaki , Kazuhisa Mitsuda , Nao Yoshida , Mikiko Saito , Takayuki Homma

Transition-edge sensors (TES) are photon-number resolving calorimetric spectrometers with near unit efficiency. Their recovery time, which is on the order of microseconds, limits the number resolving ability and timing accuracy in high…

Instrumentation and Detectors · Physics 2018-12-21 Jianwei Lee , Lijiong Shen , Alessandro Cerè , Thomas Gerrits , Adriana E. Lita , Sae Woo Nam , Christian Kurtsiefer

Transition Edge Sensor (TES) bolometers are a well-established technology with a strong track record in experimental cosmology, making them ideal for current and future radio astronomy instruments. The Tomographic Ionized-carbon Mapping…

Instrumentation and Methods for Astrophysics · Physics 2025-10-06 Victoria L. Butler , James J. Bock , Dongwoo T. Chung , Abigail T. Crites , King Lau , Ian Lowe , Dan P. Marrone , Evan C. Mayer , Benjamin J. Vaughan , Michael Zemcov

Transition-Edge Sensors (TESs) are very effective photon-number-resolving (PNR) detectors that have enabled many photonic quantum technologies. However, their relatively slow thermal recovery time severely limits their operation rate in…

We present a strip transition-edge sensor microcalorimeter linear array detector developed for energy dispersive X-ray diffraction imaging and Compton scattering applications. The prototype detector is an array of 20 transition-edge-sensors…

Instrumentation and Detectors · Physics 2020-03-18 U. Patel , R. Divan , L. Gades , T. Guruswamy , D. Yan , O. Quaranta , A. Miceli

SPT-3G is a polarization-sensitive receiver, installed on the South Pole Telescope, that measures the anisotropy of the cosmic microwave background (CMB) from degree to arcminute scales. The receiver consists of ten 150~mm-diameter detector…

The European Research Council has recently funded HOLMES, a project with the aim of performing a calorimetric measurement of the electron neutrino mass measuring the energy released in the electron capture decay of 163Ho. The baseline for…

Instrumentation and Detectors · Physics 2016-01-20 A. Giachero , P. K. Day , P. Falferi , M. Faverzani , E. Ferri , C. Giordano , M. Maino , B. Margesin , R. Mezzena , R. Nizzolo , A. Nucciotti , A. Puiu , L. Zanetti

The Transition-Edge Sensors (TES) is a mature, high-resolution x-ray spectrometer technology that provides a much higher efficiency than dispersive spectrometers such as gratings and crystal spectrometers. As larger arrays are developed,…

Instrumentation and Detectors · Physics 2018-06-08 K. D. Irwin , S. Chaudhuri , H. -M. Cho , C. Dawson , S. Kuenstner , D. Li , C. J. Titus , B. A. Young

We report on thin-film processing improvements in the fabrication of superconducting quasiparticle-trap-assisted electrothermal-feedback transition-edge sensors (QETs) used in the design of Cryogenic Dark Matter Search (CDMS) detectors. The…

Materials Science · Physics 2014-10-13 John Mark Kreikebaum , Blas Cabrera , Jeff Yen , Paul Brink , Astrid Tomada , Matt Cherry , Betty Young

Transition-edge sensors (TESs) are sensitive devices for detecting photons from millimeter radiation to gamma rays. Their photon counting efficiency and collecting area benefit from large-array multiplexing scheme, and therefore the…

Instrumentation and Methods for Astrophysics · Physics 2024-04-03 N. Li , G. Liao , D. Yan , Y. Xu , Y. Zhang , Z. Liu , S. Yuan , Y. Zhang , H. Gao , Y. Li , Y. Gu , C. Liu , H. Li , Z. Li , X. Ren

At SRON we have been developing X-ray TES micro-calorimeters as backup technology for the X-ray Integral Field Unit (X-IFU) of the Athena mission, demonstrating excellent resolving powers both under DC and AC bias. We also developed a…

Instrumentation and Methods for Astrophysics · Physics 2025-06-04 D. Vaccaro , H. Akamatsu , L. Gottardi , M. de Wit , M. P. Bruijn , J. van der Kuur , K. Nagayoshi , E. Taralli , K. Ravensberg , J. R. Gao , J. W. A. den Herder
‹ Prev 1 3 4 5 6 7 10 Next ›