English
Related papers

Related papers: High-resolution calorimetric sample platforms for …

200 papers

A differential, membrane-based nanocalorimeter for general specific heat studies of very small samples, ranging from 0.5 mg to sub-{\mu}g in mass, is described. The calorimeter operates over the temperature range from above room temperature…

Instrumentation and Detectors · Physics 2012-08-20 S. Tagliati , V. M. Krasnov , A. Rydh

We have developed a new micro-fabricated platform for the measurement of the specific heat of low heat capacity mg-sized metallic samples, such as superconductors, down to temperatures of as low as $10\,\mathrm{mK}$. It addresses…

Instrumentation and Detectors · Physics 2020-03-24 Andreas Reifenberger , Andreas Reiser , Sebastian Kempf , Andreas Fleischmann , Christian Enss

We describe a compact calorimeter that opens ultra-low temperature heat capacity studies of small metal crystals in moderate magnetic fields. The performance is demonstrated on the canonical heavy Fermion metal YbRh2Si2. Thermometry is…

Instrumentation and Detectors · Physics 2024-07-02 Jan Knapp , Lev V. Levitin , Ján Nyéki , Manuel Brando , John Saunders

Membrane based nanocalorimeters have been developed for ac calorimetry experiments. It has allowed highly sensitive measurements of heat capacity from solid state physics to complex systems like polymers and proteins. In this article we…

Specific heat is a powerful probe offering insights into the entropy and excitation spectrum of the studied material. While it is well established, a key challenge remains the measurements of microcrystals or thin films especially in the…

Strongly Correlated Electrons · Physics 2025-07-16 Mari C. Cole , Maximilian T. Pelly , Craig V. Topping , Thomas Reindl , Ulrike Waizmann , Jürgan Weis , Andreas W. Rost

Cellular metabolic rate is a good indicator of the physiological state of cells and its changes, which can be measured by total heat flux accompanying metabolism. Chip calorimeters can provide label-free and high throughput measurements of…

Biological Physics · Physics 2019-03-13 Jihye Kim , Sumin Seo , Jonghyun Kim , Sungmin Nam , Wonhee Lee

Heat capacity measurements under high pressure places high demands on the calorimeter. Here we describe the development of a miniaturized nanocalorimeter for high-pressure heat capacity measurements at low temperature. The device,…

Instrumentation and Detectors · Physics 2025-01-30 Neha Kondedan , Andreas Rydh

We introduce a nanocalorimetric technique based on microsecond-pulsed heating (\mu s-PHnC) that enables high-sensitivity, quasi-isothermal heat capacity measurements on nanoscale samples. Such resolution is critical for exploring…

Heat capacity measurements using the ac steady state method are often considered difficult to provide absolute accuracy. By adjusting the working frequency to maintain a constant phase and using the phase information to obtain the heat…

Superconductivity · Physics 2015-06-04 S. Tagliati , A. Rydh

We have developed a new calorimeter for measuring thermodynamic properties in pulsed magnetic fields. An instrumental design is described along with the construction details including the sensitivity of a RuO2 thermometer. The operation of…

Instrumentation and Detectors · Physics 2021-04-14 Shusaku Imajo , Chao Dong , Akira Matsuo , Koichi Kindo , Yoshimitsu Kohama

Cryogenic microcalorimeters are key tools for high-resolution X-ray spectroscopy due to their excellent energy resolution and quantum efficiency close to 100%. Multiple types of microcalorimeters exist, some of which have already proven…

Instrumentation and Detectors · Physics 2023-10-26 Constantin Schuster , Sebastian Kempf

We demonstrate a setup combining fast scanning calorimetry with X-ray total scattering at a synchrotron beamline, allowing for \emph{in-situ} characterizations of the nano-scale structure of samples during and after temperature scans. The…

Recent developments of the AC-calorimetric technique adapted for the needs of high pressure experiments are discussed. A semi-quantitative measurement of the specific heat with a Bridgman-type of pressure cell as well as a diamond anvil…

Strongly Correlated Electrons · Physics 2015-06-24 Heribert Wilhelm

This work presents a self-heating study of a 40-nm bulk-CMOS technology in the ambient temperature range from 300 K down to 4.2 K. A custom test chip was designed and fabricated for measuring both the temperature rise in the MOSFET channel…

Applied Physics · Physics 2021-06-16 P. A. 't Hart , M. Babaie , A. Vladimirescu , F. Sebastiano

A detailed description of an isoperibol calorimeter for temperatures between 0.05 and 4 K is presented. The proposed setup can provide absolute values of the heat capacity $C$ of small samples (typically 1 mg). The extremely simple design…

Instrumentation and Detectors · Physics 2012-02-13 M. Brando

This work builds on the previous introduction [1] of a coupled experimental-computational system devised to fully characterize the thermal behavior of complex 3D submicron electronic devices. The new system replaces the laser-based surface…

Materials Science · Physics 2007-09-13 Peter E. Raad , Pavel L. Komarov , M. Burzo

Next-generation high-energy electron-positron colliders, operating as Higgs factories, require an unprecedented jet energy resolution for precision measurements of Higgs and Z/W bosons. To address this challenge, a conceptual design is…

Instrumentation and Detectors · Physics 2026-03-10 Baohua Qi , Fangyi Guo , Shu Li , Yong Liu , Manqi Ruan , Weizheng Song , Shengsen Sun , Yifang Wang , Yuexin Wang , Haijun Yang , Yang Zhang , Zhiyu Zhao

Reflection measurements give access to the complex impedance of a material on a wide frequency range. This is of interest to study the dynamical properties of various materials, for instance disordered superconductors. However reflection…

Instrumentation and Detectors · Physics 2015-06-17 P. Diener , F. Couëdo , C. Marrache-Kikuchi , M. Aprili , J. Gabelli

We have developed a cryogenic characterization platform for ultrafast photodiodes, whose time domain responses are extracted by electro-optic sampling using femtosecond laser pulses in a pump-probe configuration. The excitation of the…

Application of Micromegas for sampling calorimetry puts specific constraints on the design and performance of this gaseous detector. In particular, uniform and linear response, low noise and stability against high ionisation density…

‹ Prev 1 2 3 10 Next ›