Related papers: High-resolution calorimetric sample platforms for …
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling…
Plasma diagnostics have a shortage of fast and sensitive calorimetric sensors that can track substrate temperature during plasma-assisted microfabrication. In this work, energy fluxes from argon and oxygen radiofrequency (RF) glow…
The CALICE Semi-Digital Hadron Calorimeter technological prototype completed in 2011 is a sampling calorimeter using Glass Resistive Plate Chamber (GRPC) detectors as the active medium. This technology is one of the two options proposed for…
The characteristic frequencies of a system provide important information on the phenomena that govern its physical properties. In this framework, there has recently been renewed interest in cryogenic microwave characterization for condensed…
We describe a helium source cell for use in cryogenic experiments that is hermetically sealed $in$ $situ$ on the cold plate of a cryostat. The source cell is filled with helium gas at room temperature and subsequently sealed using a cold…
Metallic microcalorimeters (MMCs) are cryogenic single-particle detectors that rely on a calorimetric detection principle. Due to their excellent energy resolution, close-to-ideal linear detector response, fast signal rise time and the…
X-ray Compton spectroscopy is one of the few direct probes of the electron momentum distribution of bulk materials in ambient and operando environments. We report high-resolution inelastic X-ray scattering experiments with high momentum and…
The design, calibration, and initial application of a non-contact high-temperature furnace developed for in situ synchrotron X-ray experiments are presented. The system enables a stable operation up to 1000 {\deg}C, with heating rates…
Superconducting microcalorimeters, such as superconducting transition-edge sensors and magnetic microcalorimeters, have emerged as state-of-the-art detectors for X-ray emission spectroscopy by combining near-unity quantum efficiency with…
We demonstrate radiofrequency thermometry on a micrometer-sized metallic island below 100 mK. Our device is based on a normal metal-insulator-superconductor tunnel junction coupled to a resonator with transmission readout. In the first…
Temperature sensors with micro- and nanoscale spatial resolution have long been explored for their potential to investigate the details of physical systems at an unprecedented scale. In particular, the rapid miniaturization of transistor…
A high granularity hadronic 1 m3 calorimeter prototype with semi-digital readout has been designed and built. This calorimeter has been made using stainless steel as absorber and Glass Resistive Plates Chambers (GRPC) as active medium, and…
The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section…
Low-temperature calorimeters based on a readout via Transition Edge Sensors (TESs) and operated below $100$ mK are well suited for rare event searches with outstanding resolution and low thresholds. We present first experimental results…
This paper deals with an analytical modeling of heat transfers simulating a new radiation calorimeter operating in a temperature range from -50 {\deg}C to 150 {\deg}C. The aim of this modeling is the evaluation of the feasibility and…
In the context of developing a hadron calorimeter with extremely fine granularity for the application of Particle Flow Algorithms to the measurement of jet energies at a future lepton collider, we report on extensive tests of a small scale…
Recently, great progress has been made in the field of ultrasensitive microwave detectors, reaching even the threshold for utilization in circuit quantum electrodynamics. However, cryogenic sensors lack the compatibility with broad-band…
The complex ac impedance of a bolometer or microcalorimeter detector is easily measured and can be used to determine thermal time constants, thermal resistances, heat capacities, and sensitivities. Accurately extracting this information…
We report on the resistance behavior of bare-chip Cernox thermometers under pressures up to 2 GPa, generated in a piston-cylinder pressure cell. Our results clearly show that Cernox thermometers, frequently used in low-temperature…
The measurement of energy is a fundamental tool used, for example, in exploring the early universe, characterizing particle decay processes, as well as in quantum technology and computing. Some of the most sensitive energy detectors are…