Related papers: Dose-LET Interactions Predict Capsular Contracture…
Proton therapy can achieve a highly targeted treatment by utilising the advantageous dosimetric characteristics of the Bragg Peak. Protons traversing through a material will deposit their maximum energy at the Bragg Peak through ionisation…
Purpose: Currently, calculations of proton range in proton therapy patients are based on a conversion of CT Hounsfield Units of patient tissues into proton relative stopping power. Uncertainties in this conversion necessitate larger…
Radiotherapy (RT) is a critical cancer treatment, with volumetric modulated arc therapy (VMAT) being a commonly used technique that enhances dose conformity by dynamically adjusting multileaf collimator (MLC) positions and monitor units…
This study aims to evaluate the functional status of bilateral neurovascular bundles (NVBs) using pulsed wave Doppler ultrasound in patients undergoing prostate radiotherapy (RT). Sixty-two patients (mean age: 66.1 +/- 7.2 years) underwent…
Purpose: To evaluate the cumulative radiobiological impact of daily Megavoltage Cone-Beam Computed Tomography (MV-CBCT) imaging dose based on Normal Tissue Complication Probability (NTCP) and Excess Absolute Risk (EAR) of secondary…
Functional limitation after lung resection surgery has been consistently documented in clinical studies, and right ventricle (RV) dysfunction has been hypothesized as a contributing reason. However, the mechanisms of RV dysfunction after…
Background. Clinical parameters measured from gated single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) have value in predicting cardiac resynchronization therapy (CRT) patient outcomes, but still show…
Two full rotating gantry with different nozzles (Multipurpose nozzle with MLC, Scanning Dedicated nozzle) with conventional cyclotron system is installed and under commissioning for various proton treatment options at Samsung Medical Center…
We test the feasibility of calculating proton stopping power (SP) from a set of virtual monochromatic (VM) CT images, created with Monte Carlo-generated CT scans, using a dual-energy CT-to-SP procedure. The Monte Carlo CT simulations, with…
Charged particle therapy (CPT) is an advanced modality of radiation therapy which has grown rapidly worldwide, driven by recent developments in technology and methods of delivery. To ensure safe and high quality treatments, various…
Background and Purpose: Voxel-based analysis (VBA) helps to identify dose-sensitive regions by aligning individual dose distributions within a common coordinate system (CCS). Accurate deformable image registration (DIR) is essential for…
Using inelastic proton-proton interactions at sqrt(s) = 900 GeV and 7 TeV, recorded by the ATLAS detector at the LHC, measurements have been made of the correlations between forward and backward charged-particle multiplicities and, for the…
The dilepton production is investigated in proton-nucleus collisions in the forward region using the Color Glass Condensate approach. The transverse momentum distribution ($p_T$), more precisely the low $p_T$ region, where the saturation…
Radiation dose is an important performance indicator of a dedicated breast CT (DBCT). In this paper, the method of putting thermoluminescent dosimeters (TLD) into a breast shaped PMMA phantom to study the dose distribution in breasts was…
The high cost and low image quality traditionally associated with proton computed tomography (pCT) have prevented it from seeing significant use in clinical settings. A cheap, compact, high-density scintillating glass detector capable of…
Depth distributions of positron-emitting nuclei in PMMA phantoms are calculated within a Monte Carlo model for Heavy-Ion Therapy (MCHIT) based on the GEANT4 toolkit (version 8.0). The calculated total production rates of $^{11}$C, $^{10}$C…
Microdosimetry provides a superior characterization of the radiation field compared to conventional LET-based methodology, and for this reason it has become increasingly attractive for quality assurance in particle therapy. However, the…
Proton radiography combined with X-ray computed tomography (CT) has been proposed to obtain a patient-specific calibration curve and reduce range uncertainties in cancer treatment with charged particles. The main aim of this study was to…
We investigated the effects of scanning speed, beam configuration, and dose-rate modeling on the FLASH effect in post-mastectomy proton transmission-beam (TB) planning and evaluated whether optimizing the spot-scanning path can enhance…
Radiation therapy with protons as of today utilizes information from x-ray CT in order to estimate the proton stopping power of the traversed tissue in a patient. The conversion from x-ray attenuation to proton stopping power in tissue…