Related papers: Optimized Broadband Cryogenic Ferromagnetic Resona…
Ferromagnetic resonance (FMR) serves as a powerful probe of magnetization dynamics and anisotropy in percolating ferromagnets, where short-range interactions govern long-range magnetic order. We apply this approach to Ga$_{1-x}$Mn$_x$N ($x…
This work presents for the first time a flexible over-moded resonator (OMR) based on P(VDF-TrFE) thin films. The devices were manufactured on commercially available elastic substrate with inkjet-printed electrodes. The sensing copolymer…
Ferromagnetic resonance (FMR) in magnetic multilayers of type F1/f/F2, where two strongly ferromagnetic layers F1 and F2 are separated by a weakly magnetic spacer f with a compositional gradient along its thickness, is investigated. The…
We report on the implementation of a scanning nitrogen-vacancy (NV) magnetometer in a dry dilution refrigerator. Using pulsed optically detected magnetic resonance combined with efficient microwave delivery through a co-planar waveguide, we…
Large-scale cryogenic quantum systems are constrained by an input-output bottleneck between room-temperature electronics and millikelvin stages, particularly in superconducting qubit platforms. This bottleneck is most acute for output…
Radiation hard helium gas ionization chambers capable of operating in vacuum at temperatures ranging from 5K to 350K have been designed, fabricated and tested and will be used inside the cryostats at Fermilab's Superconducting…
Up-to-date network telemetry is the key enabler for resource optimization by capacity scaling, fault recovery, and network reconfiguration among other means. Reliable optical performance monitoring in general and, specifically, the…
This paper describes a THz transmission spectrometer for the spectral range of 2-65 cm^-1 (100 GHz to 2 THz) with a spectral resolution of at least 1.8 cm^-1 (50 GHz) where the source, sample, and detector are all fully contained in a…
A quasi-optical (QO) test bench was designed, simulated, and calibrated for characterizing S-parameters of devices in the 220-330 GHz (WR-3.4) frequency range, from room temperature down to 4.8 K. The devices were measured through vacuum…
We describe a low-cost and simple setup for hyperthermia measurements on colloidal solutions of magnetic nanoparticles (ferrofluids) with a frequency-adjustable magnetic field in the range 5-500 kHz produced by an electromagnet. By…
The characteristic frequencies of a system provide important information on the phenomena that govern its physical properties. In this framework, there has recently been renewed interest in cryogenic microwave characterization for condensed…
We present a photonic ultra-wideband frequency extension for a commercial Vector Network Analyzer (VNA) to perform free-space measurements in a frequency range from 70 GHz up to 520 GHz with a Hz level resolution. The concept is based on…
We describe an instrument which can be used to analyze complex chemical mixtures at high resolution and high sensitivity. Molecules are collisionally cooled with helium gas at cryogenic temperatures (~ 4-7 K), and subsequently detected…
Aluminum nitride (AlN)-based thin-film bulk acoustic wave resonators (FBARs) are promising compact platforms for 6G communications and quantum memory hardware, enabled by their integrable acoustic modes with high quality factors. However,…
Quantum computing has emerged as a promising technology for next-generation information processing, utilizing semiconductor quantum dots as one of the candidates for quantum bits. Radio-frequency (rf) reflectometry plays an important role…
Recently, great progress has been made in the field of ultrasensitive microwave detectors, reaching even the threshold for utilization in circuit quantum electrodynamics. However, cryogenic sensors lack the compatibility with broad-band…
Imaging the vibrations of nanomechanical resonators means measuring their flexural mode shapes from the dependence of their frequency response on in-plane position. Applied to two-dimensional resonators, this technique provides a wealth of…
We demonstrate indirect electric-field control of ferromagnetic resonance (FMR) in devices that integrate the low-loss, molecule-based, room-temperature ferrimagnet vanadium tetracyanoethylene (V[TCNE]$_{x \sim 2}$) mechanically coupled to…
Normal nuclear magnetic resonance (NMR) probes cannot be used to make high frequency resolution measurements in a cryogenic environment because they lose their frequency resolution when the liquid sample in the probe freezes. A gaseous…
The operation of superconducting qubits requires a sensitive readout circuit at cryogenic temperatures, driving the demand for cryogenic non reciprocal microwave components such as circulators. However, evaluating these components at low…