Related papers: Optimized Broadband Cryogenic Ferromagnetic Resona…
We develop a high frequency, wide bandwidth radiometer operating at room temperature, which augments the traditional technique of Johnson noise thermometry for nanoscale thermal transport studies. Employing low noise amplifiers and an…
Signal to noise ratios (SNR) in magnetic resonance microscopy images are limited by acquisition times and the decreasing number of spins in smaller voxels. Significant SNR gains from cooling of the RF receiver are only realized when the…
We present an instrument to perform frequency-domain electron spin resonance (ESR) experiments that is based on coplanar waveguides and field modulation. A large parameter space in frequency (up to 25 GHz), magnetic field (up to 8 T), and…
Nanomechanical resonators (NMRs) offer a promising alternative to traditional thermal-based radiation detectors due to their immunity to electrical noise. In recent years, these sensors have reached the previously unattained theoretical…
We report the development of a variable-temperature Kelvin probe force microscopy (KPFM) system capable of stable and highly sensitive operation over a wide temperature range based on a GM-cooler-based cryogen-free cryostat. The system…
A new cryogenic noise calibration source for radio astronomy receivers is presented. Dissipated power is only 4.2 mW, allowing it to be integrated with the cold part of the receiver. Measured long-term stability, sensitivity to bias…
The cryogenic performance of GaN-based HEMTs (high-electron-mobility transistors) is systematically investigated by the direct current (DC) and low-frequency noise (LFN) characteristics within the temperature (T) range from 300 K to 4.2 K.…
The design and performance of an electron spin resonance spectrometer operating at 3 and 9 GHz microwave frequencies combined with a 9 T superconducting magnet is described. The probehead contains a compact two-loop, one gap resonator and…
Suspended high-overtone bulk acoustic wave resonators (HBARs) can serve as a viable optomechanical platform for efficient transduction of signals from the microwave to the optical frequency domain. In contrast to 1D nanobeam optomechanical…
In the search for a novel MRI contrast agent which relies on T1 shortening due to quadrupolar interaction between Bi nuclei and protons, a fast scanning wideband system for zero-field nuclear quadrupole resonance (NQR) spectroscopy is…
We discuss a cryogenic, multi-object near-infrared spectrometer as a second generation instrument for the VLT. The spectrometer combines 20 to 40 independent integral eld units (IFUs), which can be positioned by a cryogenic robot over the…
We report the development of a continuous-wave and pulsed X-band electron spin resonance (ESR) spectrometer for the study of spins on ordered surfaces down to cryogenic temperatures. The spectrometer operates in ultra-high vacuum and…
Field-deployable integrated photonic devices co-packaged with electronics will enable important applications such as optical interconnects, quantum information processing, precision measurements, spectroscopy, and microwave generation.…
In modern power systems, shiftable loads contribute to the flexibility needed to increase robustness and ensure security. Thermal loads are among the most promising candidates for providing such service due to the large thermal storage time…
This paper describes the setup and the results of the direct on-wafer measurements of a FET noise parameters obtained with a source-pull method at temperatures down to T=4K and in the 5-12 GHz frequency range. The setup consists of a…
We demonstrate an atomic radio-frequency (RF) receiver and spectrum analyzer based on thermal Rydberg atoms coupled to a planar microwave waveguide. We use an off-resonant RF heterodyne technique to achieve continuous operation for carrier…
We report on the design and performance of a cryogenic (300 mK) near-field scanning microwave microscope. It uses a microwave resonator as the near-field sensor, operating at a frequency of 6 GHz and microwave probing amplitudes down to 100…
The nitrogen-vacancy (NV) center in diamond has been recognized as a high-sensitivity nanometer-scale metrology platform. Thermometry has been a recent focus, with attention largely confined to room temperature applications. Thermometry has…
The sensitive detection of either static or radio-frequency \textsc{(rf)} magnetic fields is essential to many fundamental studies and applications. Here, we demonstrate the operation of a cold-atom-based, \textsc{rf} magnetometer in…
This paper presents the characterization of microwave passive components, including metal-oxide-metal (MoM) capacitors, transformers, and resonators, at deep cryogenic temperature (4.2 K). The variations in capacitance, inductance and…