English
Related papers

Related papers: A muon scattering tomography system based on high …

200 papers

Muon scattering tomography (MST) is a non-destructive technique to image various materials by utilizing cosmic ray muons as probes. A typical MST system with a two-fold track detectors is particularly effective in detecting high-$Z$…

Instrumentation and Detectors · Physics 2023-08-22 Jiahui Chen , Huiling Li , Yiyue Li , Pingcheng Liu

Muon tomography (MT), based on atmospheric cosmic rays, is a promising technique suitable for nondestructive imaging of the internal structures of mountains. This method uses the measured flux distribution after attenuation, combined with…

Instrumentation and Detectors · Physics 2022-12-27 Bin Zhang , Zhe Wang , Shaomin Chen

Muon Scattering Tomography (MST) has been shown to be a powerful technique for the non-invasive imaging of high-shielded objects. We present here the application of the MST technique to investigate two types of nuclear waste packages, a…

Instrumentation and Detectors · Physics 2022-05-13 A. F. Alrheli , D. Barker , C. De Sio , D. Kikoła , A. K. Kopp , M. Mhaidra , J. P. Stowell , L. F. Thompson , J. J. Velthuis , M. J. Weekes

Muon Tomography based on the measurement of multiple scattering of atmospheric cosmic ray muons in matter is a promising technique for detecting heavily shielded high-Z radioactive materials (U, Pu) in cargo or vehicles. The technique uses…

Instrumentation and Detectors · Physics 2015-11-26 Kondo Gnanvo , Leonard V. Grasso , Marcus Hohlmann , Judson B. Locke , Amilkar S. Quintero , Debasis Mitra

This work reports numerical simulations and statistical tests carried out to study the performance of a prototype imaging setup to be developed for material discrimination using Muon Scattering Tomography (MST). The reconstructed images…

Instrumentation and Detectors · Physics 2020-08-26 Sridhar Tripathy , Jaydeep Datta , Nayana Majumdar , Supratik Mukhopadhyay

Cosmic ray muon has strong penetrating power and no ionizing radiation hazards, which makes it an ideal probe for detecting special nuclear materials. In this paper, a high spatial resolution muon tomography system based on Micromegas…

Instrumentation and Detectors · Physics 2022-02-16 Yu Wang , Zhiyong Zhang , Shubin Liu , Zhongtao Shen , Changqing Feng , Jianguo Liu , Yulin Liu

Muon tomography based on the measurement of multiple scattering of atmospheric cosmic ray muons is a promising technique for detecting and imaging heavily shielded high-Z nuclear materials such as enriched uranium. This technique could…

Instrumentation and Detectors · Physics 2016-11-17 K. Gnanvo , B. Benson , W. Bittner , F. Costa , L. Grasso , M. Hohlmann , J. B. Locke , S. Martoiu , H. Muller , M. Staib , A. Tarazona , J. Toledo

Muon Tomography (MT) based on the measurement of multiple scattering of atmospheric cosmic ray muons traversing shipping containers is a promising candidate for identifying threatening high-Z materials. Since position-sensitive detectors…

Instrumentation and Detectors · Physics 2009-06-25 Marcus Hohlmann , Patrick Ford , Kondo Gnanvo , Jennifer Helsby , David Pena , Richard Hoch , Debasis Mitra

Muon tomography is a non-destructive imaging technique that exploits cosmic-ray muons from multiple directions. Its performance critically depends on the stability, active-area coverage, and spatial resolution of position-sensitive…

Instrumentation and Detectors · Physics 2025-12-02 Yiyue Li , Huiling Li , Hui Liang , Cong Liu , Chenghan Lv , Hongbo Wang , Weiwei Xu

Tomographic imaging techniques using the Coulomb scattering of cosmic-ray muons are increasingly being exploited for the non-destructive assay of shielded containers in a wide range of applications. One such application is the…

Muon imaging, especially muon scattering tomography (MST), has recently garnered significant attention. MST measures the magnitude of muon scattering angles inside an object, which depends not only on the material properties but also on the…

Instrumentation and Detectors · Physics 2025-09-17 Pei Yu , Ziwen Pan , Jiajia Zhai , Yu Xu , Li Deng , Zhengyang He , Zhe Chen , Zechao Kang , Yuhong Yu , Xueheng Zhang , Liangwen Chen , Lei Yang , Zhiyu Sun

We present results from a detailed GEANT4 simulation of a proposed Muon Tomography System that employs compact Micro Pattern Gas Detectors with high spatial resolution. A basic Point-Of-Closest-Approach algorithm is applied to reconstructed…

Instrumentation and Detectors · Physics 2016-11-15 Kondo Gnanvo , Patrick Ford , Jennifer Helsby , Richie Hoch , Debasis Mitra , Marcus Hohlmann

Muon tomography is a technique that uses cosmic ray muons to generate three dimensional images of volumes using information contained in the Coulomb scattering of the muons. Advantages of this technique are the ability of cosmic rays to…

Muon tomography is developing as a promising system to detect high-Z (atomic number) material for ensuring homeland security. In the present work, three kinds of spatial locations of materials which are made of aluminum, iron, lead and…

Instrumentation and Detectors · Physics 2016-08-04 Xiao-Dong Wang , Kai-Xuan Ye , Yu-Lei Li , Wen Luo , Hui-Yin Wu , He-Run Yang , Guo-Xiang Chen , Zhi-Chao Zhu , Xiu-Liang Zhao

A semiconductor tracker for muon scattering tomography is presented. The tracker contains silicon strip sensors with an $80\,\mu$m pitch, precision mechanics and integrated cooling. The electronic readout of the sensors is performed by a…

Instrumentation and Detectors · Physics 2018-10-30 F. Keizer , A. Gorbatch , M. A. Parker , C. Steer , S. A. Wotton

Cosmic-ray muons are highly penetrative charged particles that are observed at sea level with a flux of approximately one per square centimetre per minute. They interact with matter primarily through Coulomb scattering, which is exploited…

This work presents a novel cosmic-ray scattering experiment employing a Resistive Plate Chambers (RPC) muon tomography system. By introducing the scattering angle between incident and outgoing cosmic-ray tracks as a key observable, this…

The muon tomography technique, based on multiple Coulomb scattering of cosmic ray muons, has been proposed as a tool to detect the presence of high density objects inside closed volumes. In this paper a new and innovative method is…

Muon radiography is an imaging technique based on muon absorption in matter that allows measurement of internal details in hidden objects or structures. This technique relies on measuring cosmic-ray muons tracks accurately, which reflects…

Instrumentation and Detectors · Physics 2025-10-23 Yu Wang , Shubin Liu , Zhihang Yao , Yulin Liu , Zhiyong Zhang , Zhengyang He , Ziwen Pan , Changqing Feng

Cosmic ray muon computed tomography ({\mu}CT) is a new imaging modality with unique characteristics that could be particularly important for diverse applications including nuclear nonproliferation, spent nuclear fuel monitoring, cargo…

Instrumentation and Detectors · Physics 2018-10-17 Zhengzhi Liu , Stylianos Chatzidakis , John M. Scaglione , Can Liao , Haori Yang , Jason P. Hayward
‹ Prev 1 2 3 10 Next ›