English
Related papers

Related papers: Development & first Performance evaluation of mult…

200 papers

We present an innovative charge detector with high resolution and wide dynamic range designed to fulfill the requirements of a monitoring system for a high energy ion beam. The detector prototype, constructed using Si photodiodes and a…

A new ultra-low background high-purity germanium (HPGe) detector has been installed at the Kamioka underground experimental site. The background count rate in the energy range from 40 keV to 2700 keV is about 25% lower than that of the…

Instrumentation and Detectors · Physics 2023-12-05 K. Ichimura , H. Ikeda , Y. Kishimoto , M. Kurasawa , A. A. Suzuki , Y. Gando , M. Ikeda , K. Hosokawa , H. Sekiya , H. Ito , A. Minamino , S. Suzuki

Bragg spectroscopy is one of the best established experimental methods for high energy resolution X-ray measurements; however, this technique is limited to the measurement of photons producedfrom well collimated (tens of microns) or…

Instrumentation and Detectors · Physics 2019-03-08 A. Scordo , C. Curceanu , M. Miliucci , F. Sirghi , J. Zmeskal

An x-ray detector using a liquid-helium cooled large-area silicon PIN photodiode has been developed along with a tailor-made charge sensitive preamplifier whose first-stage JFET has been cooled. The operating temperature of the JFET has…

High Energy Physics - Experiment · Physics 2009-10-28 Yoshizumi Inoue , Shigetaka Moriyama , Hideyuki Hara , Makoto Minowa , Fumio Shimokoshi

Two GEM telescopes, each consisting of three 10x10 cm$^2$ triple-GEM chambers were built, tested and operated by the Hampton University group. The GEMs are read out with APV25 frontend chips and FPGA based digitizing electronics developed…

Instrumentation and Detectors · Physics 2018-03-02 Anusha Liyanage , Michael Kohl , Jesmin Nazeer , Tanvi Patel

Characteristics improvement of photon/plasmon detectors have been the subject of several investigations in the area of plasmonic integrated circuits. Among different suggestions, Silicon-based Metal-Semiconductor-Metal (MSM) waveguides are…

Applied Physics · Physics 2019-01-31 Elahe Rastegar Pashaki , Hassan Kaatuzian , Abdolber Mallah Livani

A new ultra low-level counting setup has been installed in the shallow-underground laboratory Felsenkeller in Dresden, Germany. It includes a high-purity germanium detector (HPGe) of 163\% relative efficiency within passive and active…

Instrumentation and Detectors · Physics 2023-02-09 S. Turkat , D. Bemmerer , A. Boeltzig , A. R. Domula , J. Koch , T. Lossin , M. Osswald , K. Schmidt , K. Zuber

A dedicated in-vacuum X-ray detector based on the hybrid pixel PILATUS 1M detector has been installed at the four-crystal monochromator beamline of PTB at the electron storage ring BESSY II in Berlin. Due to its windowless operation, the…

Instrumentation and Detectors · Physics 2014-08-01 Jan Wernecke , Christian Gollwitzer , Peter Müller , Michael Krumrey

Recently synthesized novel phase of germanium selenide ({\gamma}-GeSe) adopts a hexagonal lattice and a surprisingly high conductivity than graphite. This triggers great interests in exploring its potential for thermoelectric applications.…

Materials Science · Physics 2023-08-11 Zheng Shu , Bowen Wang , Xiangyue Cui , Xuefei Yan , Hejin Yan , Huaxian Jia , Yongqing Cai

A fast method to determine the crystallographic axes of segmented true-coaxial high-purity germanium detectors is presented. It is based on the analysis of segment-occupancy patterns obtained by irradiation with radioactive sources. The…

Nuclear Experiment · Physics 2012-03-27 I. Abt , A. Caldwell , J. Liu , B. Majorovits , P. Petrov , O. Volynets

We report a ground X-ray calibration of two X-ray telescope prototypes at the PANTER X-ray Test Facility, of the Max-Planck-Institute for Extraterrestrial Physics, in Neuried, Germany. The X-ray telescope prototypes were developed by the…

This article reports the characterization of two High Purity Germanium detectors performed by extracting and comparing their efficiencies using experimental data and Monte Carlo simulations. The efficiencies were calculated for pointlike…

The usage of muonic X-rays to study elemental properties like nuclear radii ranges back to the seventies. This triggered the pioneering work at the Paul Scherrer Institute (PSI), during the eighties, on the Muon Induced X-ray Emission…

High-Voltage Monolithic Active Pixel Sensors (HV-MAPS) based on the 180 nm HV-CMOS process have been proposed to realize thin, fast and highly integrated pixel sensors. The MuPix7 prototype, fabricated in the commercial AMS H18 process,…

The full-energy-peak efficiency of HPGe detectors at $\gamma$-ray energies around 10 MeV is not easily accessible with experimental methods. Monte-Carlo simulations with Geant4 can provide these efficiencies. G4Horus is a ready-to-use…

Instrumentation and Detectors · Physics 2020-06-15 Jan Mayer , Elena Hoemann , Markus Müllenmeister , Philipp Scholz , Andreas Zilges

Pixel sensors based on commercial high-voltage CMOS processes are an exciting technology that is considered as an option for the outer layer of the ATLAS inner tracker upgrade at the High Luminosity LHC. Here, charged particles are detected…

Following work done in the energy region above 100 keV, the high-precision calibration of a co-axial high-purity germanium detector has been continued in the energy region below 100 keV. Previous measurements or Monte-Carlo simulations have…

Instrumentation and Detectors · Physics 2020-04-08 B. Blank , P. Ascher , M. Gerbaux , J. Giovinazzo , S. Grevy , T. Kurtukian Nieto , M. Versteegen , J. C. Thomas

Preclinical research and organ-dedicated applications require high-resolution positron emission tomography (PET) detectors to visualize small structures and understand biological processes at a finer level of detail. Current commercial…

Measurements with a bare p-type high purity germanium diode (HPGe) submerged in a 19 kg liquid argon (LAr) scintillation detector at MPIK Heidelberg are reported. The liquid argon--germanium system (LArGe) is operated as a 4$\pi$…

Instrumentation and Detectors · Physics 2008-11-26 M. Di Marco , P. Peiffer , S. Schönert