English
Related papers

Related papers: Fast Reconstruction of Motion-Corrupted Data with …

200 papers

Purpose: Pushing MRI speed further demands more spatially-encoded information captured per unit time, e.g., by superimposing additional field modulations during oversampled readout. However, this can introduce calibration errors and…

Medical Physics · Physics 2026-01-12 Rui Tian , Martin Uecker , Oliver Holder , Pavel Povolni , Theodor Steffen , Klaus Scheffler

In fMRI, capturing brain activation during a task is dependent on how quickly k-space arrays are obtained. Acquiring full k-space arrays, which are reconstructed into images using the inverse Fourier transform (IFT), that make up volume…

Applications · Statistics 2024-05-27 Chase J Sakitis , Daniel B Rowe

MRI data is acquired in Fourier space/k-space. Data acquisition is typically performed on a Cartesian grid in this space to enable the use of a fast Fourier transform algorithm to achieve fast and efficient reconstruction. However, it has…

Signal Processing · Electrical Eng. & Systems 2024-01-17 Daniel Abraham , Mark Nishimura , Xiaozhi Cao , Congyu Liao , Kawin Setsompop

Robotic grasping is a cornerstone capability of embodied systems. Many methods directly output grasps from partial information without modeling the geometry of the scene, leading to suboptimal motion and even collisions. To address these…

k-space undersampling is a standard technique to accelerate MR image acquisitions. Reconstruction techniques including GeneRalized Autocalibrating Partial Parallel Acquisition(GRAPPA) and its variants are utilized extensively in clinical…

Image and Video Processing · Electrical Eng. & Systems 2021-02-17 Nader Tavaf , Amirsina Torfi , Kamil Ugurbil , Pierre-Francois Van de Moortele

Magnetic Resonance Imaging (MRI) is a powerful medical imaging modality, but unfortunately suffers from long scan times which, aside from increasing operational costs, can lead to image artifacts due to patient motion. Motion during the…

Image and Video Processing · Electrical Eng. & Systems 2023-10-02 Brett Levac , Sidharth Kumar , Ajil Jalal , Jonathan I. Tamir

Purpose: To develop a scan-specific model that estimates and corrects k-space errors made when reconstructing accelerated Magnetic Resonance Imaging (MRI) data. Methods: Scan-Specific Artifact Reduction in k-space (SPARK) trains a…

Signal Processing · Electrical Eng. & Systems 2022-04-29 Yamin Arefeen , Onur Beker , Jaejin Cho , Heng Yu , Elfar Adalsteinsson , Berkin Bilgic

Purpose: To characterize the noise distributions in 3D-MRI accelerated acquisitions reconstructed with GRAPPA using an exact noise propagation analysis that operates directly in k--space. Theory and Methods: We exploit the extensive…

Simultaneous Multi-Slice(SMS) is a magnetic resonance imaging (MRI) technique which excites several slices concurrently using multiband radiofrequency pulses to reduce scanning time. However, due to its variable data structure and…

Image and Video Processing · Electrical Eng. & Systems 2025-01-13 Ting Zhao , Zhuoxu Cui , Congcong Liu , Xingyang Wu , Yihang Zhou , Dong Liang , Haifeng Wang

Magnetic Resonance Imaging allows high resolution data acquisition with the downside of motion sensitivity due to relatively long acquisition times. Even during the acquisition of a single 2D slice, motion can severely corrupt the image.…

Numerical Analysis · Mathematics 2024-04-12 Mathias S. Feinler , Bernadette N. Hahn

Motion artifacts are a pervasive problem in MRI, leading to misdiagnosis or mischaracterization in population-level imaging studies. Current retrospective rigid intra-slice motion correction techniques jointly optimize estimates of the…

Image and Video Processing · Electrical Eng. & Systems 2023-11-17 Nalini M. Singh , Neel Dey , Malte Hoffmann , Bruce Fischl , Elfar Adalsteinsson , Robert Frost , Adrian V. Dalca , Polina Golland

This paper studies the joint reconstruction of traffic speeds and travel times by fusing sparse sensor data. Raw speed data from inductive loop detectors and floating cars as well as travel time measurements are combined using different…

Signal Processing · Electrical Eng. & Systems 2021-05-11 Lisa Kessler , Felix Rempe , Klaus Bogenberger

Magnetic resonance imaging (MRI) is highly susceptible to patient motion due to its relatively long acquisition times and the fact that data are acquired sequentially in k-space. Even small patient movements introduce phase inconsistencies…

Computer Vision and Pattern Recognition · Computer Science 2026-05-22 Antonio Ortiz-Gonzalez , Erich Kobler , Lukas Schletter , Alexander Effland

Respiration-induced B$_0$ fluctuation corrupts MRI images by inducing phase errors in k-space. A few approaches such as navigator have been proposed to correct for the artifacts at the expense of sequence modification. In this study, a new…

Image and Video Processing · Electrical Eng. & Systems 2020-10-09 Hongjun An , Hyeong-Geol Shin , Sooyoen Ji , Woojin Jung , Sehong Oh , Dongmyung Shin , Juhyung Park , Jongho Lee

Purpose: To develop an efficient navigator-based motion and temporal B0 shift correction technique for 3D multi-echo gradient-echo (ME-GRE) MRI for quantitative susceptibility mapping (QSM) and R2* mapping. Theory and Methods: A dual-echo…

Medical Physics · Physics 2024-03-20 Yuguang Meng , Jason W. Allen , Vahid Khalilzad Sharghi , Deqiang Qiu

In fully sampled cardiac MR (CMR) acquisitions, motion can lead to corruption of k-space lines, which can result in artefacts in the reconstructed images. In this paper, we propose a method to automatically detect and correct motion-related…

Image and Video Processing · Electrical Eng. & Systems 2019-06-14 lkay Oksuz , James Clough , Bram Ruijsink , Esther Puyol-Anton , Aurelien Bustin , Gastao Cruz , Claudia Prieto , Daniel Rueckert , Andrew P. King , Julia A. Schnabel

With the proliferation of mobile devices, the need for an efficient model to restore any degraded image has become increasingly significant and impactful. Traditional approaches typically involve training dedicated models for each specific…

Computer Vision and Pattern Recognition · Computer Science 2024-12-19 Bin Ren , Eduard Zamfir , Zongwei Wu , Yawei Li , Yidi Li , Danda Pani Paudel , Radu Timofte , Ming-Hsuan Yang , Nicu Sebe

Data processing has to deal with many practical difficulties. Data is often corrupted by artifacts or noise and acquiring data can be expensive and difficult. Thus, the given data is often incomplete and inaccurate. To overcome these…

Numerical Analysis · Mathematics 2022-11-18 Florian Bossmann , Jianwei Ma

In multi-view human body capture systems, the recovered 3D geometry or even the acquired imagery data can be heavily corrupted due to occlusions, noise, limited field of- view, etc. Direct estimation of 3D pose, body shape or motion on…

Computer Vision and Pattern Recognition · Computer Science 2018-02-02 Zhong Li , Yu Ji , Wei Yang , Jinwei Ye , Jingyi Yu

Magnetic Resonance Imaging allows high resolution data acquisition with the downside of motion sensitivity due to relatively long acquisition times. Even during the acquisition of a single 2D slice, motion can severely corrupt the image.…

Computer Vision and Pattern Recognition · Computer Science 2023-03-31 Mathias S. Feinler , Bernadette N. Hahn
‹ Prev 1 2 3 10 Next ›