Related papers: On Improving Nuclear Fuel Imaging Using Position S…
Hard X-ray photons with energies in the range of hundreds of keV typically undergo Compton scattering when they are incident on a detector. In this process, an incident photon deposits a fraction of its energy at the point of incidence and…
The major advantage of proton therapy over conventional radiotherapy is the dose deposition pattern, enabling precise coverage of the tumour volume while sparing nearby healthy tissues. However, accurate control of the proton beam range…
We present a fingerprint-like method to analyze material defects after energetic particle irradiation by computing a rotation invariant descriptor vector for each atom of a given sample. For ordered solids this new method is easy to use,…
A 760 $\times$ 760 $\times$ 30 mm$^3$ plastic scintillation detector viewed by photomultiplier tubes (PMTs) from four corners has been developed, and the detector has been tested with cosmic rays and $\gamma$ rays. A position-independent…
Dual phase Xenon Time Projection Chambers (XeTPCs) are being used by several experiments as a promising technique for direct detection of dark matter. We report on the design and performance of a small 3-D sensitive dual phase XeTPC. The…
A new technique of elucidating $\beta$-decay schemes of isotopes with large density of states at low excitation energies has been developed, in which a Broad Energy Germanium (BEGe) detector is used in conjunction with coaxial hyper-pure…
For dose calculations in ion beam therapy, it is vital to accurately determine the relative stopping power (RSP) distribution within the treated volume. Currently, RSP values are extrapolated from Hounsfield units (HU), measured with x-ray…
Micro Pattern Gaseous Detectors (MPGDs) are used for tracking in High Energy Physics and Nuclear Physics because of their large area, excellent spatial resolution capabilities and low cost. However, for high energy charged particles…
The characteristics of the Solid-state Neutron Detector, under development for neutron-scattering measurements at the European Spallation Source, have been simulated with a Geant4-based computer code. The code models the interations of…
Nowadays, the current threat of international terrorism is set to a severe level, demanding worldwide enhanced security. Radioactive materials that could be fashioned into a radiation dispersal device typically emit gamma rays, while…
The microstructural characteristics of soot generated during thermal runaway events in lithium-ion batteries have been examined, with a focus on the associated health risks. X-ray computed tomography (Nano-CT) offers advanced 3D imaging for…
A new detector is being developed at the National Superconducting Cyclotron Laboratory (NSCL) to measure low energy charged-particles from beta-delayed particle emission. These low energy particles are very important for nuclear…
Advances in the technologies associated with position sensitive gaseous detectors especially featuring CsI as reflective photoconverters will be reviewed. These photodetectors represent the most effective solution for what concerns cost and…
The concept of a small, single-layer water Cherenkov detector, with three photomultiplier tubes (PMTs), placed at its bottom in a $120^{\circ}$ star configuration (\emph{Mercedes} Water Cherenkov Detector) is presented. The PMTs are placed…
For its ease manufacturing, flexible geometry, and cheap manufacturing cost, the gas electron multiplier (GEM) detector can be used as an x-ray image sensor. For this purpose, we acquired relative detection efficiencies and suggested a…
Tomographic imaging with radionuclides commonly used in nuclear medicine, such as $^{111}$In (171 and 245 keV) and $^{131}$I (364 keV), is in high demand for medical applications and small animal imaging. The Si/CdTe Compton camera with its…
The use of photon counting detection technology has resulted in significant X-ray imaging research interest in recent years. Computed Tomography (CT) scanners can benefit from photon-counting detectors, which are new technology with the…
The Modified Horizontal Bridgman (MHB) process produces Cadmium Zinc Telluride (CZT) crystals with high yield and excellent homogeneity. Various groups,including our own, previously reported on the test of 2x2x0.5 cm3 MHB CZT detectors…
The forward proton detectors, already existing at the LHC, are considered in the context of heavy ion collisions. It is shown that such detectors have the potential to measure nuclear debris originating from spectator nucleons. The…
Optically read out gaseous detectors are used in track reconstruction and imaging applications requiring high granularity images. Among resolution-determining factors, the amplification stage plays a crucial role and optimisations of…