English
Related papers

Related papers: An efficient approach with theoretical guarantees …

200 papers

Positron emission tomography (PET) is a cornerstone of modern radiology. The ability to detect cancer and metastases in whole body scans fundamentally changed cancer diagnosis and treatment. One of the main bottlenecks in the clinical…

Computer Vision and Pattern Recognition · Computer Science 2022-04-28 Ida Häggström , C. Ross Schmidtlein , Gabriele Campanella , Thomas J. Fuchs

Positron Emission Tomography (PET) is a functional imaging modality widely used in neuroscience studies. To obtain meaningful quantitative results from PET images, attenuation correction is necessary during image reconstruction. For PET/MR…

Medical Physics · Physics 2018-08-01 Kuang Gong , Jaewon Yang , Kyungsang Kim , Georges El Fakhri , Youngho Seo , Quanzheng Li

Positron Emission Tomography (PET) is a crucial tool in medical imaging, particularly for diagnosing diseases like cancer and Alzheimer's. The advent of Positronium Lifetime Imaging (PLI) has opened new avenues for assessing the tissue…

Medical Physics · Physics 2024-03-25 Zhuo Chen , Chien-Min Kao , Hsin-Hsiung Huang , Lingling An

Quantitative PET attenuation correction (AC) for combined cardiac PET/MR is a challenging problem. We propose and evaluate an AC approach that uses coincidences from a relatively weak and physically fixed sparse external source, in…

Medical Physics · Physics 2023-01-02 Mi-Ae Park , Vlad G. Zaha , Ramsey D. Badawi , Spencer L. Bowen

Low-count reconstruction remains a challenge for Positron Emission Tomography (PET) even with the recent progress in time-of-flight (TOF) resolution. In this context, the bias between the acquired histogram, consisting of low values or…

Medical Physics · Physics 2023-01-12 Maxime Toussaint , Francis Loignon-Houle , Roger Lecomte , Jean-Pierre Dussault

We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (TB) Jagiellonian PET (J-PET) scanners. The method is…

Historically, patient datasets have been used to develop and validate various reconstruction algorithms for PET/MRI and PET/CT. To enable such algorithm development, without the need for acquiring hundreds of patient exams, in this paper we…

Proton computed tomography (CT) is similar to x-ray CT but relies on protons rather than photons to form an image. In its most common operation mode, the measured quantity is the amount of energy that a proton has lost while traversing the…

Medical Physics · Physics 2022-08-17 Nils Krah , Denis Dauvergne , Jean Michel Létang , Simon Rit , Étienne Testa

Standard dual-energy computed tomography (CT) uses two different X-ray energies to obtain energy-dependent tissue attenuation information to allow quantitative material decomposition. The combined use of dual-energy CT and positron emission…

Medical Physics · Physics 2020-12-30 Guobao Wang

The International Atomic Energy Agency (IAEA) has recently approved passive gamma emission tomography (PGET) as a method for inspecting spent nuclear fuel assemblies (SFAs), an important aspect of international nuclear safeguards which aim…

Instrumentation and Detectors · Physics 2019-05-13 Rasmus Backholm , Tatiana A. Bubba , Camille Bélanger-Champagne , Tapio Helin , Peter Dendooven , Samuli Siltanen

Complete time of flight (TOF) sinograms of state-of-the-art TOF PET scanners have a large memory footprint. Currently, they contain ~4e9 data bins which amount to ~17GB in 32bit floating point precision. Using iterative algorithms to…

Medical Physics · Physics 2022-05-24 Georg Schramm , Martin Holler

Positron emission tomographs (PET) do not measure an image directly. Instead, they measure at the boundary of the field-of-view (FOV) of PET tomograph a sinogram that consists of measurements of the sums of all the counts along the lines…

We consider the problem of joint reconstruction of both attenuation $a$ and source density $f$ in emission tomography in two dimensions. This is sometimes called the Single Photon Emission Computed Tomography (SPECT) identification problem,…

Analysis of PDEs · Mathematics 2020-01-14 Sean Holman , Philip Richardson

Artificial intelligence (AI) is entering medical imaging, mainly enhancing image reconstruction. Nevertheless, improvements throughout the entire processing, from signal detection to computation, potentially offer significant benefits. This…

Machine Learning · Computer Science 2023-10-27 Stephan Naunheim , Yannick Kuhl , David Schug , Volkmar Schulz , Florian Mueller

Photomultiplier tubes (PMTs) are widely used in particle and nuclear physics experiments. The reconstruction of PMT waveforms is a fundamental task in these experiments, where accurate extraction of photoelectron (PE) multiplicities and…

High Energy Physics - Experiment · Physics 2026-05-29 Yiming Xu , Youwen Fan , Siyu Chen , Hongyue Duyang , Teng Li , Yaoguang Wang

Attenuation compensation (AC) is a pre-requisite for reliable quantification and beneficial for visual interpretation tasks in single-photon emission computed tomography (SPECT). Typical AC methods require the availability of an attenuation…

Medical Physics · Physics 2021-02-12 Zitong Yu , Md Ashequr Rahman , Thomas Schindler , Richard Laforest , Abhinav K. Jha

Positron emission tomography (PET) is an important modality for diagnosing diseases such as cancer and Alzheimer's disease, capable of revealing the uptake of radiolabeled molecules that target specific pathological markers of the diseases.…

Medical Physics · Physics 2025-01-17 Hsin-Hsiung Huang , Zheyuan Zhu , Slun Booppasiri , Zhuo Chen , Shuo Pang , Chien-Min Kao

We study a simple modification to the conventional time of flight mass spectrometry (TOFMS) where a \emph{variable} and (pseudo)-\emph{random} pulsing rate is used which allows for traces from different pulses to overlap. This modification…

Optimization and Control · Mathematics 2013-07-30 Morteza Ibrahimi , Andrea Montanari , George S Moore

A method for mathematical treatment is considered for experimental data from pulsed time-of-flight spectrometers, whose response to measurement-initiating pulses is represented by their convolution with the pulse response of the system. The…

General Physics · Physics 2018-12-11 Andrey V. Novikov-Borodin

The EndoTOFPET-US project aims to jointly exploit Time-Of-Flight Positron Emission Tomography (TOFPET) and ultrasound endoscopy with a multi-modal instrument for the development of new biomarkers for pancreas and prostate oncology. The…

Instrumentation and Detectors · Physics 2013-03-20 Erika Garutti