English
Related papers

Related papers: Short-wave infrared broadband up-conversion imagin…

200 papers

Spiral phase contrast is an important and convenient imaging processing technology in edge detection, and a broader field-of-view (FOV) of imaging is a long-pursuing aim to see more regions of the illumination objects. Compared with…

Frequency upconversion technique offers an appealing approach for sensitive mid-infrared (MIR) imaging at room temperature. However, the spatial resolution of the upconversion imager has been notoriously restricted by the limited transverse…

Upconversion imaging, where mid infrared (IR) photons are converted to visible and near IR photons via a nonlinear crystal and detected on cheap and high-performance Silicon detectors, is an appealing method to address the limitations of…

Optics · Physics 2020-02-05 Michael Mrejen , Yoni Erlich , Assaf Levanon , Haim Suchowski

Mid-infrared (MIR) spectral imaging enables precise target identification and analysis by capturing rich chemical fingerprints, which calls for high-sensitivity broadband MIR imagers at room temperature. Here, we devise and implement a…

Optics · Physics 2026-05-26 Yue Song , Jianan Fang , Wen Zhang , Yijing Li , Ben Sun , Zhiwei Jia , Kun Huang , Heping Zeng

Quantitative phase microscopy (QPM), a technique combining phase imaging and microscopy, enables visualization of the 3D topography in reflective samples, as well as the inner structure or refractive index distribution of transparent and…

Optics · Physics 2025-01-17 Vicente Mico , Juanjuan Zheng , Javier Garcia , Zeev Zalevsky , Peng Gao

Infrared imaging is indispensable for its ability to penetrate obscurants and visualize thermal signatures, yet its practical use is hindered by the intrinsic limitations of conventional detectors. Nonlinear upconversion, which converts…

Ultrafast mid-infrared (MIR) imaging is a key enabling capability for monitoring transient thermal and plasma phenomena in scientific diagnostics and industrial safety. However, conventional cryogenic MIR cameras face a fundamental…

We demonstrate a photon-sensitive, three-dimensional camera by active near-infrared illumination and fast time-of-flight gating. It uses pico-second pump pulses to selectively up-convert the backscattered photons according to their…

Optics · Physics 2022-11-01 He Zhang , Santosh Kumar , Yong Meng Sua , Shenyu Zhu , Yu-Ping Huang

Frequency up-conversion is an effective method of mid-infrared (MIR) detection by converting the long-wavelength photons to the visible domain, where efficient detectors are readily available. Here, we generate the MIR light carrying…

We present a scheme for estimating the noise-equivalent temperature difference (NETD) of frequency upconversion detectors (UCDs) that detect mid-infrared (MIR) light. In particular, this letter investigates the frequency upconversion of a…

Ultra-broadband imaging devices with high performance are in great demand for a variety of technological applications, including imaging, remote sensing, and communications. An ultra-broadband up-converter is realized based on a p-GaAs…

High-quality crystals without inversion symmetry are the conventional platform to achieve optical frequency conversion via three wave-mixing. In bulk crystals, efficient wave-mixing relies on phase-matching configurations, while at the…

Multispectral mid-infrared (2-5 ${{\mu}m}$) imaging is a critical capability across science and technology, offering a window into the vibrational and thermal landscape of matter that is inaccessible to visible sensors. It bridges the…

Optics · Physics 2026-01-29 Daniel Beitner , Ziv Abelson , Eyal Hollander , Omri Meron , Haim Suchowski

Silicon photodetectors are highly desirable for their CMOS compatibility, low cost, and fast response speed. However, their application the infrared (IR) is limited by silicon's intrinsic bandgap, which restricts its detection to photons…

Long-wavelength infrared band exhibits significant utility in thermal signature acquisition and molecular spectral analysis, among other applications. The up-conversion detection technique enables effective signal transduction into the…

This paper presents a polarization calibration method applied to a microwave polarimeter demonstrator based on a near-infrared (NIR) frequency up-conversion stage that allows both optical correlation and signal detection at a wavelength of…

Instrumentation and Methods for Astrophysics · Physics 2022-10-25 Francisco J. Casas , Patricio Vielva , R. Belen Barreiro , Enrique Martínez-González , G. Pascual-Cisneros

We report on the observation of broadband (40 THz) bright twin beams through high-gain parametric down-conversion in an aperiodically poled lithium niobate crystal. The output photon number is shown to scale exponentially with the pump…

Quasi-phase matching (QPM) is a technique extensively utilized in nonlinear optics for enhancing the efficiency and stability of frequency conversion processes. However, the conventional QPM relies on periodically poled ferroelectric…

Given that the phase amplification method based on harmonic generation exhibits significant phase super-resolution capability in interferometric precision measurement, extending this technology to birefringence interferometers to achieve…

Optics · Physics 2025-03-13 Wuzhen Li , Zhiyuan Zhou , Guangcan Guo , Baosen Shi

Edge-enhanced imaging is critical for visualizing weakly absorbing and transparent objects. Extending this functionality into the mid-infrared (MIR) region enables chemical sensitivity and improved imaging performance for biomedical,…

‹ Prev 1 2 3 10 Next ›