Related papers: Cryogenic geometric anti-spring vibration isolatio…

200 papers

We demonstrate successful operation of a continuous flow liquid helium magnetic cryostat (Oxford Instruments, Microstat MO) in closed cycle operation using a modular cryocooling system (ColdEdge Technologies, Stinger). For the system…

Instrumentation and Detectors · Physics 2022-01-04 K. Barr , T. Cookson , K. G. Lagoudakis

Noise filtering is an essential part for measurement of quantum phenomena at extremely low temperatures. Here, we present the design of a filter which can be installed in space constrained cryogenic environment containing a large number of…

Instrumentation and Detectors · Physics 2011-03-02 Soumen Mandal , Tobias Bautze , Remi Blinder , Tristan Meunier , Laurent Saminadayar , Christopher Bäuerle

We present the design and characterization of a cryogenic vacuum chamber incorporating mechanical isolation from vibrations, a high numerical-aperture in-vacuum imaging objective, in-vacuum magnetic shielding, and an antenna for global…

We describe an instrument which can be used to analyze complex chemical mixtures at high resolution and high sensitivity. Molecules are collisionally cooled with helium gas at cryogenic temperatures (~ 4-7 K), and subsequently detected…

Instrumentation and Detectors · Physics 2019-05-22 Jessica P. Porterfield , Lincoln Satterthwaite , Sandra Eibenberger , David Patterson , Michael C. McCarthy

In low temperature transport measurements, there is frequently a need to protect a device at cryogenic temperatures from thermal noise originating in warmer parts of the experiment. There are also a wide range of experiments, such as high…

Other Condensed Matter · Physics 2007-05-23 Lafe Spietz , John Teufel , R. J. Schoelkopf

Closed cycle $He^{3}-He^{4}$ dilution cryostats became the platform of choice in quantum sciences in the era of helium shortage. However, in many experiments, the mechanical vibrations induced by the pulsed cryocoolers present a significant…

Mesoscale and Nanoscale Physics · Physics 2023-02-28 Jacob Franklin , Joshua Bedard , Ilya Sochnikov

We present results from cryogenic tests of a Volume-Phase Holographic (VPH) grating at 200 K measured at near-infrared wavelengths. The aims of these tests were to see whether the diffraction efficiency and angular dispersion of a VPH…

We developed a system that continuously maintains a cryocooler for long periods on a rotating table. A cryostat that holds the cryocooler is set on the table. A compressor is located on the ground and supplies high-purity (> 99.999%) and…

Instrumentation and Methods for Astrophysics · Physics 2014-07-21 Shugo Oguri , Jihoon Choi , Masanori Kawai , Osamu Tajima

Current experiments aimed at measuring the polarization of the Cosmic Microwave Background (CMB) use cryogenic detector arrays and cold optical systems to boost the mapping speed of the sky survey. For these reasons, large volume cryogenic…

Instrumentation and Methods for Astrophysics · Physics 2022-04-27 S. Masi , E. S. Battistelli , P. de Bernardis , C. Chapron , F. Columbro , G. D'Alessandro , M. De Petris , L. Grandsire , J. -Ch. Hamilton , S. Marnieros , L. Mele , A. May , A. Mennella , C. O'Sullivan , A. Paiella , F. Piacentini , M. Piat , L. Piccirillo , G. Presta , A. Schillaci , A. Tartari , J. -P. Thermeau , S. A. Torchinsky , F. Voisin , M. Zannoni , P. Ade , J. G. Alberro , A. Almela , G. Amico , L. H. Arnaldi , D. Auguste , J. Aumont , S. Azzoni , S. Banfi , B. Bélier , A. Baù , D. Bennett , L. Bergé , J. -Ph. Bernard , M. Bersanelli , M. -A. Bigot-Sazy , J. Bonaparte , J. Bonis , E. Bunn , D. Burke , D. Buzi , F. Cavaliere , P. Chanial , R. Charlassier , A. C. Cobos Cerutti , A. Coppolecchia , G. De Gasperis , M. De Leo , S. Dheilly , C. Duca , L. Dumoulin , A. Etchegoyen , A. Fasciszewski , L. P. Ferreyro , D. Fracchia , C. Franceschet , M. M. Gamboa Lerena , K. M. Ganga , B. García , M. E. García Redondo , M. Gaspard , D. Gayer , M. Gervasi , M. Giard , V. Gilles , Y. Giraud-Heraud , M. Gómez Berisso , M. González , M. Gradziel , M. R. Hampel , D. Harari , S. Henrot-Versillé , F. Incardona , E. Jules , J. Kaplan , C. Kristukat , L. Lamagna , S. Loucatos , T. Louis , B. Maffei , W. Marty , A. Mattei , M. McCulloch , D. Melo , L. Montier , L. Mousset , L. M. Mundo , J. A. Murphy , J. D. Murphy , F. Nati , E. Olivieri , C. Oriol , F. Pajot , A. Passerini , H. Pastoriza , A. Pelosi , C. Perbost , M. Perciballi , F. Pezzotta , G. Pisano , M. Platino , G. Polenta , D. Prêle , R. Puddu , D. Rambaud , E. Rasztocky , P. Ringegni , G. E. Romero , J. M. Salum , C. G. Scóccola , S. Scully , S. Spinelli , G. Stankowiak , M. Stolpovskiy , A. D. Supanitsky , P. Timbie , M. Tomasi , G. Tucker , C. Tucker , D. Viganò , N. Vittorio , F. Wicek , M. Wright , A. Zullo

This paper brings out results of a measurement campaign aiming to determine the temperature coefficients of synthetic quartz elastic constants at liquid helium temperature. The method is based on the relationship between the resonance…

Other Condensed Matter · Physics 2016-12-21 Jérémy Bon , Serge Galliou , Roger Bourquin

In this paper we present details of the construction of a wideband, cryogenic receiver and its successful commissioning on the Arecibo 12m telescope. The cryogenic receiver works in the 2.5-14 GHz frequency range. The telescope is operated…

Instrumentation and Methods for Astrophysics · Physics 2023-08-14 D. Anish Roshi , Phil Perillat , Felix Fernandez , Hamdi Mani , Benetge Perera , P. K. Manoharan , Luis Quintero , Arun Venkataraman

We report on a scanned superconducting quantum interference device (SQUID) microscope operating in a cryogen-free cryostat, with the capability of up to forty RF connections with 20 GHz bandwidth to a device under test. The system utilizes…

Superconductivity · Physics 2025-09-10 Ian W. Haygood , Bochao Xu , John Biesecker , Michael L. Schneider

This article focuses on the prediction of the vibration frequency response of handheld probes. A novel approach that involves machine learning and readily available data from probes was explored. Vibration probes are efficient and…

Applied Physics · Physics 2024-02-09 Roberto San Millán-Castillo , Eduardo Morgado , Rebeca Goya Esteban

In some experiments and applications there is need for large-area photosensitive detectors to operate at cryogenic temperatures. Nowadays, vacuum PMs are usually used for this purpose. We have developed special designs of planar…

Instrumentation and Detectors · Physics 2009-11-11 L. Periale , V. Peskov , C. Iacobaeus , B. Lund-Jensen , P. Pavlopoulos , P. Picchi , F. Pietropaolo

Many modern nanofabrication and imaging techniques require an ultra-quiet environment to reach optimal resolution. Isolation from ambient vibrations is often achieved by placing the sensitive instrument atop a massive block that floats on…

Instrumentation and Detectors · Physics 2021-01-19 Wenjie Gong , Yu Liu , Wan-Ting Liao , Joseph Gibbons , Jennifer E. Hoffman

Cryogenic cooling of the test masses of interferometric gravitational wave detectors is a promising way to reduce thermal noise. However, cryogenic cooling limits the incident power to the test masses, which limits the freedom of shaping…

General Relativity and Quantum Cosmology · Physics 2018-12-07 Yuta Michimura , Kentaro Komori , Atsushi Nishizawa , Hiroki Takeda , Koji Nagano , Yutaro Enomoto , Kazuhiro Hayama , Kentaro Somiya , Masaki Ando

Cryogen-free dilution refrigerators generally simplify low temperature research but some types of samples, including superconducting qubits and other nanoelectronic devices, are affected by environmental heat sources such as stray photons…