Related papers: Thermal Noise Measurement Below the Standard Quant…
We have studied the origin of switching (telegraph) noise at low temperature in lateral quantum structures defined electrostatically in GaAs/AlGaAs heterostructures by surface gates. The noise was measured by monitoring the conductance…
Atomic projection noise limits the ultimate precision of all atomic sensors, including clocks, inertial sensors, magnetometers, etc. The independent quantum collapse of $N$ atoms into a definite state (for example spin up or down) leads to…
Thermal noise is the predominant instability in the provision of ultrastable laser frequency, referencing to an optical cavity. Reducing the thermal-noise limit of a cavity means either making it larger to spread thermal fluctuations,…
We report on experimental observation of radiation-pressure induced effects in a high-power optical cavity. These effects play an important role in next generation gravitational wave (GW) detectors, as well as in quantum non-demolition…
The quantum measurement of any observable naturally leads to noise added by the act of measurement. Approaches to evade or reduce this noise can lead to substantial improvements in a wide variety of sensors, from laser interferometers to…
We demonstrate an easy to manufacture, 25 mm long ultra-stable optical reference cavity for transportable photonic microwave generation systems. Employing a rigid holding geometry that is first-order insensitive to the squeezing force and a…
We apply noise thermometry to characterize charge and thermoelectric transport in single InAs nanowires (NWs) at a bath temperature of 4.2 K. Shot noise measurements identify elastic diffusive transport in our NWs with negligible…
We have investigated crystalline AlGaAs/GaAs optical coatings with three ultra-stable cavities operating at 4 K, 16 K, 124 K and 297 K. The response of the resonance frequencies of cavities to variations in optical power indicates effects…
State-of-the-art optical oscillators based on lasers frequency stabilized to high finesse optical cavities are limited by thermal noise that causes fluctuations of the cavity length. Thermal noise represents a fundamental limit to the…
Three-mode parametric instability is a threat to attaining design power levels in Advanced gravitational wave detectors. The first observation of three-mode parametric instability in a long optical cavity revealed that instabilities could…
We demonstrate a cryogenic optomechanical system comprising a flexible Si3N4 membrane placed at the center of a free-space optical cavity in a 400 mK cryogenic environment. We observe a mechanical quality factor Q > 4 x 10^6 for the 261-kHz…
Here we demonstrate the capacity to manipulate the optical spring (OS) effect by employing an optical parametric amplifier (OPA) within an optical cavity. We observed more than a factor of 2 increase in the OS frequency shift with the OPA.…
We demonstrate for a passive optical cavity containing a dispersive atomic medium, the increase in scale factor near the critical anomalous dispersion is not cancelled by mode broadening or attenuation, resulting in an overall increase in…
Temperature fluctuations are expected to be one of the limiting factors for gravitational wave detectors in the very low frequency range. Here we report the characterisation of this noise source in the LISA Pathfinder optical bench and…
The displacement fluctuations of mirrors in optomechanical devices, induced via thermal expansion by temperature fluctuations due either to thermodynamic fluctuations or to fluctuations in the photon absorption, can be made smaller than…
We describe a cryogenic cavity-optomechanical system that combines Si3N4 membranes with a mechanically-rigid Fabry-Perot cavity. The extremely high quality-factor frequency products of the membranes allow us to cool a MHz mechanical mode to…
We study the crossover between thermal and shot-noise power in a chaotic quantum dot in the presence of non-ideal contacts at finite temperature. The result explicitly demonstrates that the temperature affect the suppression-amplification…
We develop and demonstrate a compact (less than $6$ mL) portable Fabry-P\'{e}rot optical reference cavity. A laser locked to the cavity is thermal noise limited at $2\times10^{-14}$ fractional frequency stability. Broadband feedback control…
Heating induced by the noise postulated in wave function collapse models leads to a lower bound to the temperature of solid objects. For the noise parameter values $\lambda ={\rm coupling~strength}\sim 10^{-8} {\rm s}^{-1}$ and $r_C ={\rm…
Current research on micro-mechanical resonators strives for quantum-limited detection of the motion of macroscopic objects. Prerequisite to this goal is the observation of measurement backaction consistent with quantum metrology limits.…