Related papers: Thermal Noise Measurement Below the Standard Quant…
We demonstrate AFM imaging with a microcantilever force transducer where an integrated superconducting microwave resonant circuit detects cantilever deflection using the principles of cavity optomechanics. We discuss the detector…
This paper demonstrates the use of voltage noise thermometry, with a cross-correlation technique, as a dissipation-free method of thermometry inside a CMOS integrated circuit (IC). We show that this technique exhibits broad agreement with…
We propose two Fabry-Perot cavities, each pumped through both the mirrors, positioned in line as a toy model of the gravitational-wave (GW) detector free from displacement noise of the test masses. It is demonstrated that the displacement…
Low-noise temperature measurements at frequencies in the milli-Hertz range are needed in the LISA and LISA PathFinder (LPF). The required temperature stability for LISA is around 10 uK/sqrt(Hz) at frequencies down to 0.1 mHz. In this paper…
We investigate the thermal expansion of low thermal noise Fabry-Perot cavities made of Low Thermal Expansion (LTE) glass spacers and Fused Silica (FS) mirrors. The different thermal expansion of mirror and spacer deforms the mirror. This…
Recent observations made with Advanced LIGO and Advanced Virgo have initiated the era of gravitational-wave astronomy. The number of events detected by these "2nd Generation" (2G) ground-based observatories is partially limited by noise…
Here, we present the thermal tuning capability of an alignment-free fiber-integrated Fabry-P\'erot cavity.The two mirrors are made of fiber Bragg gratings that can be individually temperature stabilized and tuned. We show the temperature…
Probes that measure the local thermal properties of systems out of equilibrium are emerging as new tools in the study of nanoscale systems. One can then measure the temperature of a probe that is weakly coupled to a bias-driven system. By…
We study the mechanical fluctuations of a micrometer sized silicon cantilever subjected to a strong heat flow, thus having a highly non-uniform local temperature. In this non-equilibrium steady state, we show that fluctuations are…
It is shown that an optical parametric amplifier inside a cavity can considerably improve the cooling of the micromechanical mirror by radiation pressure. The micromechanical mirror can be cooled from room temperature 300 K to sub-Kelvin…
We demonstrate a cavity-enhanced room-temperature magnetic field sensor based on nitrogen-vacancy centers in diamond. Magnetic resonance is detected using absorption of light resonant with the 1042 nm spin-singlet transition. The diamond is…
Optical multilayer coatings of high-reflective mirrors significantly determine the properties of Fabry-Perot resonators. Thermal (Brownian) noise in these coatings produce excess phase noise which can seriously degrade the sensitivity of…
Classical ways of cooling require some of these elements: phase transition, compressor, non-linearity, valve, and/or switch. A recent example is the 2018 patent of Linear Technology Corporation; they utilize the shot noise of a diode to…
The sensitivity of future gravitational wave (GW) observatories will be limited by thermal noise in a wide frequency band. To reduce thermal noise, the European GW observatory Einstein GW Telescope (ET) is suggested to use crystalline…
Ultra-high sensitivity detection of quantum-scale displacements in cavity optomechanics optimises the combined errors from measurement back-action and imprecisions from incoming quantum noises. This sets the well-known Standard Quantum…
We report a direct measurement of the low-frequency noise spectrum in a superconducting flux qubit. Our method uses the noise sensitivity of a free-induction Ramsey interference experiment, comprising free evolution in the presence of noise…
Dephasing induced by residual thermal photons in the readout resonator is a leading factor limiting the coherence times of qubits in the circuit QED architecture. This residual thermal population, of the order of $10^{-1}$--$10^{-3}$, is…
Optical Vector Analysers (OVA) are critical for emerging technologies such as integrated photonics and optical positioning. Achieving a sensitivity near the Standard Quantum Limit (SQL) while acquiring a wide spectrum allows an accurate…
One of the noise sources that currently limits gravitational wave (GW) detectors comes from the quantum nature of the light causing uncertain amplitude and phase. Phase uncertainty limits the precision of an interferometric measurement.…
Temperature estimation, known as thermometry, is a critical sensing task for physical systems operating in the quantum regime. Indeed, thermal fluctuations can significantly degrade quantum coherence. Therefore, accurately determining the…