Purpose: We introduce a novel concept of a compact multiprobe scintillator detector and demonstrate its applicability in HDR-brachytherapy. Our fabricated seven-probe system is sufficiently narrow to be inserted in a brachytherapy needle or…
Purpose: HDR brachytherapy is a widely adopted modality for cancer treatment. However, it is not free from error and uncertainty. In-vivo dosimetry (IVD) is the only technique that can confirm correct dose delivery. This study details and…
Purpose: To present the performance of a multi-point plastic scintillation detector (mPSD) as a tool in vivo dosimetry in brachytherapy. Methods: A previously optimized three-point sensor system was used for in vivo HDR brachytherapy…
The high dose gradients near the source characteristics of brachytherapy are equivalent to nefarious effects if unnoticed errors take place during the patient treatment. In vivo dosimetry is the only method to quantify the delivered dose.…
Purpose: We sought to evaluate the feasibility of using machine learning algorithms for multipoint plastic scintillator detector calibration in high-dose-rate brachytherapy. Methods: The dosimetry system consisted of an optimized 1-mm-core…
Since large dose are administrated to the patient in brachytherapy treatment, ensuring the right dose is delivered is highly critical. This study presents a first step in solving the standing issue of accurately knowing the dosimeter…
Purpose: This study aims to optimize and characterize the response of a mPSD for in vivo dosimetry in HDR brachytherapy. Methods: An exhaustive analysis was carried out in order to obtain an optimized mPSD design that maximize the…
Plastic scintillation detectors are increasingly used to measure dose distributions in the context of radiotherapy treatments. Their water-equivalence, real-time response and high spatial resolution distinguish them from traditional…
Background: Ultra-high dose rate proton therapy shows promise in tissue sparing by enhancing therapeutic ratio through the FLASH effect. In radiotherapy, accurate in vivo dosimetry is crucial for quality assurance, but remains challenging…
The performance of a scintillating fiber detector prototype for tracking under high rate conditions is investigated. A spatial resolution of about100 micron is aimed for the detector. Further demands are low occupancy and radiation hardness…
Scintillating fibre detectors combine sub-mm resolution particle tracking, precise measurements of the particle stopping power and sub-ns time resolution. Typically, fibres are read out with silicon photomultipliers (SiPM). Hence, if fibres…
Inverse planning algorithms for dwell time optimisation in interstitial high-dose-rate (HDR) brachytherapy may produce solutions with large dwell time variations within catheters, which may result in undesirable selective high-dose…
A prototype plastic scintillating fibre based beam profile monitor was tested at the Heidelberg Ion Therapy Centre / \textit{Heidelberg Ionenstrahl Therapiezentrum} (HIT) in 2016 to determine its beam property reconstruction performance and…
Current clinical PET systems utilize detectors where the scintillator typically contains single elements of 3 - 6 mm width and about 20 mm height. While providing good TOF performance, this design limits the spatial resolution and causes…
The STAR Silicon Strip Detector (SSD) completes the three layers of the Silicon Vertex Tracker (SVT) to make an inner tracking system located inside the Time Projection Chamber (TPC). This additional fourth layer provides two dimensional…
Introduction: Real-time dosimetry of surface doses in electron beams has not been widely established yet. Plastic scintillation detectors (PSD) promise high spatial resolution and real-time dosimetry with minimum perturbation of the…
This study aims to introduce IViST (In Vivo Source Tracking), a novel multi-sensors dosimetry platform for real-time treatment monitoring in HDR brachytherapy. IViST is a platform that comprises 3 parts: 1) an optimized and characterized…
A fibre detector with multianode PM readout for high rate applications was developed for the HERA-B spectometer to cover the area near the beampipe. Such a detector has to operate at particle rates up to 2*10**4 mm**(-2) s**(-1) and has to…
Silicon strip sensors have long been a reliable technology for particle detection. Here, we push the limits of silicon tracking detectors by targeting an unprecedentedly low material budget of 2%-7% $X_0$ in an 8-layer 4 m$^2$ detector…
The modified Beer-Lambert law (MBL) and the spatially resolved spectroscopy are used to measure the tissue oxidation in muscles and brains by the continuous wave near-infrared spectroscopy. The spatially resolved spectroscopy predicts the…