English
Related papers

Related papers: Millikelvin-precision temperature sensing for adva…

200 papers

Precision physics at future multi-TeV lepton colliders such as CLIC requires excellent jet energy resolution. The detectors need deep calorimeter systems to limit the energy leakage also for very highly energetic particles and jets. At the…

Instrumentation and Detectors · Physics 2019-08-13 Frank Simon

The first operation of a cryogenic Resistive Plate WELL (RPWELL) detector in the saturated vapor of liquid argon is reported. The RPWELL detector was composed of a Thick Gas Electron Multiplier (THGEM) electrode coupled to a metallic anode…

Instrumentation and Detectors · Physics 2023-12-13 A. Tesi , S. Leardini , L. Moleri , M. Morales , D. Gonzalez-Diaz , A. Jash , A. Breskin , S. Bressler

We have developed a calibration system based on a micro-electromechanical systems (MEMS) mirror that is capable of delivering an optical beam over a wavelength range of 180 -- 2000 nm (0.62 -- 6.89 eV) in a sub-Kelvin environment. This…

Observations of the Cosmic Microwave Background rely on cryogenic instrumentation with cold detectors, readout, and optics providing the low noise performance and instrumental stability required to make more sensitive measurements. It is…

A compact, highly efficient single-particle counting detector for ions of keV/u kinetic energy, movable by a long-stroke mechanical translation stage, has been developed at the Max-Planck-Institut f\"ur Kernphysik (Max Planck Institute for…

The Cryogenic Underground Observatory for Rare Events (CUORE) is a ton-scale cryogenic experiment designed to search for neutrinoless double-beta decay of $^{130}$Te and other rare events. The CUORE detector consists of 988 TeO$_2$…

Instrumentation and Detectors · Physics 2016-11-24 J. S. Cushman , A. Dally , C. J. Davis , L. Ejzak , D. Lenz , K. E. Lim , K. M. Heeger , R. H. Maruyama , A. Nucciotti , S. Sangiorgio , T. Wise

This paper describes results on R&D of an economical and efficient cryogenic system prototype for future liquid xenon detector. The test module of the prototype has a "cold head" attached to a copper rod, which is specially designed to…

Instrumentation and Detectors · Physics 2022-07-27 Xinbei Jiang , Li Zhao , Shaobo Wang , Jia Fu , Tianjie Wu , Jianglai Liu

Resistance thermometry provides a time-tested method for taking temperature measurements. However, fundamental limits to resistance-based approaches has produced considerable interest in developing photonic temperature sensors to leverage…

Optics · Physics 2015-08-06 Haitan Xu , Mohammad Hafezi , J. Fan , J. M. Taylor , G. F. Strouse , Zeeshan Ahmed

This paper describes the cryogenic and purification systems of the ICARUS T600 detector in its present implementation at the Fermi National Laboratory, Illinois, USA. The ICARUS T600 detector is made of four large Time Projection Chambers,…

High Energy Physics - Experiment · Physics 2026-04-13 F. Abd Alrahman , P. Abratenko , N. Abrego-Martinez , A. Aduszkiewicz , F. Akbar , L. Aliaga Soplin , M. Artero Pons , J. Asaadi , W. F. Badgett , B. Behera , V. Bellini , R. Benocci , J. Berger , S. Berkman , O. Beltramello , S. Bertolucci , M. Betancourt , A. Blanchet , F. Boffelli , M. Bonesini , T. Boone , B. Bottino , A. Braggiotti , J. Bremer , S. J. Brice , V. Brio , C. Brizzolari , H. S. Budd , A. Campani , A. Campos , D. Carber , M. Carneiro , I. Caro Terrazas , H. Carranza , F. Castillo Fernandez , A. Castro , S. Centro , G. Cerati , M. Chalifour , P. Chambouvet , A. Chatterjee , D. Cherdack , S. Cherubini , N. Chithirasreemadam , T. E. Coan , A. Cocco , M. R. Convery , L. Cooper-Troendle , S. Copello , H. Da Motta , M. Dallolio , A. A. Dange , A. de Roeck , S. Di Domizio , L. Di Noto , D. Di Ferdinando , M. Diwan , S. Dolan , L. Domine , S. Donati , R. Doubnik , F. Drielsma , J. Dyer , S. Dytman , C. Fabre , A. Falcone , C. Farnese , A. Fava , N. Gallice , F. G. Garcia , C. Gatto , M. Geynisman , D. Gibin , A. Gioiosa , W. Gu , A. Guglielmi , G. Gurung , K. Hassinin , H. Hausner , A. Heggestuen , B. Howard , R. Howell , Z. Hulcher , I. Ingratta , C. James , W. Jang , Y. -J. Jwa , L. Kashur , W. Ketchum , J. S. Kim , D. -H. Koh , J. Larkin , Y. Li , C. Mariani , C. M. Marshall , S. Martynenko , N. Mauri , K. S. McFarland , D. P. Méndez , A. Menegolli , G. Meng , O. G. Miranda , D. Mladenov , A. Mogan , N. Moggi , E. Montagna , C. Montanari , A. Montanari , M. Mooney , G. Moreno-Granados , J. Mueller , M. Murphy , D. Naples , M. Nessi , T. Nichols , S. Palestini , M. Pallavicini , V. Paolone , L. Pasqualini , L. Patrizii , L. Paudel , G. Petrillo , C. Petta , V. Pia , F. Pietropaolo , F. Poppi , M. Pozzato , M. L Pumo , G. Putnam , X. Qian , A. Rappoldi , G. L. Raselli , S. Repetto , F. Resnati , A. M. Ricci , E. Richards , M. Rosenberg , M. Rossella , N. Rowe , P. Roy , C. Rubbia , M. Saad , S. Saha , G. Salmoria , S. Samanta , M. Satgia , A. Scaramelli , D. Schmit , F. Schwartz , A. Schukraft , D. Senadheera , S-H. Seo , F. Sergiampietri , G. Sirri , J. S. Smedley , J. Smith , L. Stanco , J. Stewart , H. A. Tanaka , F. Tapia , M. Tenti , K. Terao , F. Terranova , V. Togo , D. Torretta , M. Torti , F. Tortorici , R. Triozzi , Y. -T. Tsai , K. V. Tsang , S. Tufanli , T. Usher , F. Varanini , N. Vardy , S. Ventura , M. Vicenzi , C. Vignoli , B. Viren , F. A. Wieler , Z. Williams , R. J. Wilson , P. Wilson , J. Wolfs , T. Wongjirad , A. Wood , E. Worcester , M. Worcester , M. Wospakrik , S. Yadav , H. Yu , J. Yu , A. Zani , J. Zennamo , J. Zettlemoyer , C. Zhang , S. Zucchelli , M. Zuckerbrot

Cryogenic temperatures are the prerequisite for many advanced scientific applications and technologies. The accurate determination of temperature in this range and at the submicrometer scale is, however, nontrivial. This is due to the fact…

In the described device, the thermal emissivity or absorptivity of the sample is measured by substitution of the radiative heat flow between two parallel surfaces by thermal output of a heater. Fast measurements of the mutual emissivity for…

Instrumentation and Detectors · Physics 2016-10-05 Tomas Kralik , Pavel Hanzelka , Vera Musilova , Ales Srnka

Characterization of diamond-like carbon (DLC) coatings at cryogenic temperatures (down to 77 K) is presented, covering the electrical resistivity range of practical interest to gaseous and liquid particle instrumentation: 10^-1-10^5…

We find that it is possible to increase sensitivity to low energy physics in a third or fourth DUNE-like module with careful controls over radiopurity and targeted modifications to a detector similar to the DUNE Far Detector design. In…

Ionizing radiation has emerged as a potential limiting factor for superconducting quantum processors, inducing quasiparticle bursts and correlated errors that challenge fault-tolerant operation. Atmospheric muons are particularly…

Liquid argon technology is widely used by many previous and current neutrino experiments, and it is also promising for future large-scale neutrino experiments. When detecting neutrinos using liquid argon, many hadrons are involved, which…

Nuclear Experiment · Physics 2024-02-27 Yinrui Liu

The RICOCHET reactor neutrino observatory is planned to be installed at Institut Laue-Langevin starting in mid-2022. The scientific goal of the RICOCHET collaboration is to perform a low-energy and percentage-precision CENNS measurement in…

We present the main features of a home-built scanning tunneling microscope that has been attached to the mixing chamber of a dilution refrigerator. It allows scanning tunneling microscopy and spectroscopy measurements down to the base…

Superconductivity · Physics 2015-05-18 M. Marz , G. Goll , H. v. Loehneysen

A LED-based fiber calibration system for the ProtoDUNE-Dual Phase (DP) photon detection system (PDS) has been designed and validated. ProtoDUNE-DP is a 6x6x6 m3 liquid argon time-projection-chamber currently being installed at the Neutrino…

A novel, to the best of our knowledge, ultralow-temperature luminescence thermometry strategy is proposed, based on a measurement of relative intensities of hyperfine components in the spectra of Ho$^{3+}$ ions doped into a crystal. A…

Optics · Physics 2025-11-25 Marina N. Popova , Mosab Diab , Boris Z. Malkin

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne telescope designed to survey star formation over cosmological time scales using intensity mapping in the 420 - 540 GHz frequency range. EXCLAIM uses…

‹ Prev 1 4 5 6 7 8 10 Next ›