Related papers: Innovative DC-coupled Resistive Silicon Detector f…
We present our latest ASIC, which is used for the readout of Cadmium Telluride double-sided strip detectors (CdTe DSDs) and high spectroscopic imaging. It is implemented in a 0.35 um CMOS technology (X-Fab XH035), consists of 64 readout…
In the last years, high-resolution time tagging has emerged as the tool to tackle the problem of high-track density in the detectors of the next generation of experiments at particle colliders. Time resolutions below 50ps and event average…
Ultra Fast Silicon Detectors (UFSD) are sensors optimized for timing measurements employing a thin multiplication layer to increase the output signal. A multipurpose read-out board hosting a low-cost, low-power fast amplifier was designed…
A readout electronic with high time and energy resolution performance is designed for the SDD (Silicon Drift Detector) signals readout, which is aimed for X-ray pulsar based navigation (XNAV). For time measurement, the input signal is fed…
In this paper we report on the timing resolution of the first production of 50 micro-meter thick Ultra-Fast Silicon Detectors (UFSD) as obtained in a beam test with pions of 180 GeV/c momentum. UFSD are based on the Low-Gain Avalanche…
The paper reports on the timing resolution achieved with Low-Gain Avalanche Diodes (LGADs), optimised for extreme-fluence conditions, at the DESY Test Beam Facility using 4~GeV/c electrons. The LGADs adopt an $n$-in-$p$ technology with a…
The low gain avalanche detectors (LGADs) are thin sensors with fast charge collection which in combination with internal gain deliver an outstanding time resolution of about 30 ps. High collision rates and consequent large particle rates…
The non-destructive readout capability of the Skipper Charge Coupled Device (CCD) has been demonstrated to reduce the noise limitation of conventional silicon devices to levels that allow single-photon or single-electron counting. The noise…
A silicon microstrip detector (SSD) has been developed to have state of the art spatial resolution and a large sensitive area under stringent power constraints. The design incorporates three floating strips with their bias resistors…
The High Luminosity upgrade of the CERN Large Hadron Collider (HL-LHC) requires new high-radiation tolerant silicon pixel sensors for the innermost part of the tracking detector in the CMS experiment. The innermost layer of the tracker,…
The CMS Inner Tracker, made of silicon pixel modules, will be entirely replaced prior to the start of the High Luminosity LHC period. One of the crucial components of the new Inner Tracker system is the readout chip, being developed by the…
Multiple-Amplifier Sensing (MAS) charge-coupled devices (CCDs) have recently been shown to be promising silicon detectors that meet noise sensitivity requirements for next generation Stage-5 spectroscopic surveys and potentially, future…
Detectors that can simultaneously provide fine time and spatial resolution have attracted wide-spread interest for applications in several fields such as high-energy and nuclear physics as well as in low-energy electron detection, photon…
Among some of the current uses of the DC Superconducting QUantum Interference Devices (SQUIDs) are qubit-readouts and sensors for probing properties of quantum materials. We present a rather unique gradiometric niobium SQUID design with…
The compressed sensing (CS) model can represent the signal recovery process of a large number of radar systems. The detection problem of such radar systems has been studied in many pieces of literature through the technology of debiased…
We investigate the signal propagation in AC-LGAD (aka RSD), which are LGAD with a common N+ layer and segmented AC-coupled readout contacts, by measuring response to IR laser TCT on a large selection of AC-LGAD with strip readout. The…
Silicon Carbide device (4H-SiC) has potential radiation hardness, high saturated carrier velocity and low temperature sensitivity theoretically. The Silicon Low Gain Avalanche Diode (LGAD) has been verified to have excellent time…
AC-Coupled LGAD (AC-LGAD) is a new 4D detector developed based on the Low Gain Avalanche Diode (LGAD) technology, which can accurately measure the time and spatial information of particles. The Institute of High Energy Physics (IHEP)…
We developed a 2-mm-thick CdTe double-sided strip detector (CdTe-DSD) with a 250 um strip pitch, which has high spatial resolution with a uniform large imaging area of 10 cm$^2$ and high energy resolution with high detection efficiency in…
Decentralized diagnostic testing that is accurate, portable, quantitative, and capable of making multiple simultaneous measurements of different biomarkers at the point-of-need remains an important unmet need in the post-pandemic world.…