English
Related papers

Related papers: Performance and Design Validation of CMS Phase-2 P…

200 papers

The development of CMOS pixel sensors with column parallel read-out and integrated zero-suppression has resulted in a full size, nearly 1 Megapixel, prototype with ~100 \mu s read-out time. Its performances are quite close to the ILD vertex…

Instrumentation and Detectors · Physics 2010-07-16 Christine Hu-Guo , IPHC Collaboration , IRFU Collaboration

The CMS Inner Tracker, made of silicon pixel modules, will be entirely replaced prior to the start of the High Luminosity LHC period. One of the crucial components of the new Inner Tracker system is the readout chip, being developed by the…

Instrumentation and Detectors · Physics 2021-11-01 Natalia Emriskova

An efficient and precise reconstruction of charged-particle tracks is crucial for the overall performance of the CMS experiment. During Run 2 of LHC, significant upgrades were made to the track reconstruction algorithms in order to…

Instrumentation and Detectors · Physics 2020-12-15 Walaa Elmetenawee

The High-Luminosity LHC (HL-LHC) era, set to begin in 2029, will provide the general-purpose experiments with an instantaneous luminosity of up to $\mathcal{L} = 7.5 \times 10^{34}$ cm$^{-2}$ s$^{-1}$ from pp collisions at a centre-of-mass…

High Energy Physics - Experiment · Physics 2025-01-08 Thiago R. F. P. Tomei

HV-CMOS pixel sensors are a promising option for the tracker upgrade of the ATLAS experiment at the LHC, as well as for other future tracking applications in which large areas are to be instrumented with radiation-tolerant silicon pixel…

During the upcoming High Luminosity phase of the Large Hadron Collider (HL-LHC), the integrated luminosity of the accelerator will increase to 3000 fb$^{-1}$. The expected experimental conditions in that period in terms of background rates,…

Instrumentation and Detectors · Physics 2022-01-19 A. Samalan , M. Tytgat , G. A. Alves , F. Marujo , F. Torres Da Silva De Araujo , E. M. DaCosta , D. De Jesus Damiao , H. Nogima , A. Santoro , S. Fonseca De Souza , A. Aleksandrov , R. Hadjiiska , P. Iaydjiev , M. Rodozov , M. Shopova , G. Soultanov , M. Bonchev , A. Dimitrov , L. Litov , B. Pavlov , P. Petkov , A. Petrov , S. J. Qian , C. Bernal , A. Cabrera , J. Fraga , A. Sarkar , S. Elsayed , Y. Assran , M. El Sawy , M. A. Mahmoud , Y. Mohammed , C. Combaret , M. Gouzevitch , G. Grenier , I. Laktineh , L. Mirabito , K. Shchablo , I. Bagaturia , D. Lomidze , I. Lomidze , V. Bhatnagar , R. Gupta , P. Kumari , J. Singh , V. Amoozegar , B. Boghrati , M. Ebraimi , R. Ghasemi , M. Mohammadi Najafabadi , E. Zareian , M. Abbrescia , R. Aly , W. Elmetenawee , N. DeFilippis , A. Gelmi , G. Iaselli , S. Leszki , F. Loddo , I. Margjeka , G. Pugliese , D. Ramos , M. Caponero , L. Benussi , S. Bianco , S. Colafranceschi , A. Russo , L. Passamonti , D. Piccolo , D. Pierluigi , G. Saviano , S. Buontempo , A. Di Crescenzo , F. Fienga , G. DeLellis , L. Lista , S. Meola , P. Paolucci , A. Braghieri , P. Salvini , P. Montagna , C. Riccardi , P. Vitulo , B. Francois , T. J. Kim , J. Park , S. Y. Choi , B. Hong , K. S. Lee , J. Goh , H. Lee , J. Eysermans , C. Uribe Estrada , I. Pedraza , H. Castilla-Valdez , A. Sanchez-Hernandez , C. A. Mondragon Herrera , D. A. Perez Navarro , G. A. AyalaSanchez , S. Carrillo , E. Vazquez , N. Zaganidis , A. Radi , A. Ahmad , I. Asghar , H. Hoorani , S. Muhammad , M. A. Shah , B. Mandelli , R. Guida , I. Crotty

The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region) and Resistive…

We present an R&D activity focused on the development of novel modules for the upgrade of the ATLAS pixel system at the High Luminosity LHC (HL-LHC). The modules consist of n-in-p pixel sensors, 100 or 200 $\mu$m thick, produced at VTT…

Instrumentation and Detectors · Physics 2015-06-17 A. Macchiolo , L. Andricek , H. -G. Moser , R. Nisius , R. H. Richter , S. Terzo , P. Weigell

The High Luminosity Large Hadron Collider (HL-LHC) at CERN is expected to collide protons at a center-of-mass energy of 14 TeV and to reach the unprecedented peak instantaneous luminosity of $7.5 \times 10^{34} \text{cm}^{-2} \text{s}^{-1}$…

Instrumentation and Detectors · Physics 2023-01-26 Sascha Liechti

The LHC machine is planning an upgrade program, which will smoothly bring the instantaneous luminosity to about $5-7.5\times10^{34}~\mathrm{cm}^{-2}\mathrm{s}^{-1}$ in 2028, to possibly reach an integrated luminosity of 3000-4500 fb$^{-1}$…

Instrumentation and Detectors · Physics 2019-11-07 Ernesto Migliore

CMOS pixel sensors (CPS) represent a novel technological approach to building charged particle detectors. CMOS processes allow to integrate a sensing volume and readout electronics in a single silicon die allowing to build sensors with a…

The CMS muon system at the LHC is built of different detector technologies. The measurement of the background hit rates in the different muon detectors during the LHC Run-2 is of prime importance for an assessment of the longevity of the…

Instrumentation and Detectors · Physics 2020-04-22 Silvia Costantini

In order to achieve the challenging requirements on the CLIC vertex detector, a range of technology options have been considered in recent years. One prominent idea is the use of active sensors implemented in a commercial high-voltage CMOS…

The present Compact Muon Solenoid silicon pixel tracking system has been designed for a peak luminosity of 1034cm-2s-1 and total dose corresponding to two years of the Large Hadron Collider (LHC) operation. With the steady increase of the…

Instrumentation and Detectors · Physics 2011-10-11 N. Parashar

The second LHC long shutdown period (LS2) is an important opportunity for the CMS Resistive Plate Chambers (RPC) to complete their consolidation and upgrade projects. The consolidation includes detector maintenance for gas tightness, HV…

Instrumentation and Detectors · Physics 2020-12-30 Mehar Ali Shah

The CMS muon system operates gas-based detectors. Upgrades of the detectors and trigger components are needed to cope with increasingly challenging conditions of the HL-LHC. New irradiation tests are performed to ensure that the muon…

Instrumentation and Detectors · Physics 2018-09-07 Jian Wang

Since the initial data taking of the CERN LHC, the CMS experiment has undergone substantial upgrades and improvements. This paper discusses the CMS detector as it is configured for the third data-taking period of the CERN LHC, Run 3, which…

Instrumentation and Detectors · Physics 2024-06-03 CMS Collaboration

We present a readout chip prototype for future pixel detectors with timing capabilities. The prototype is intended for characterizing 4D pixel arrays with a pixel size of $100\times100~\mu \text{m}^2$, where the sensors are Low Gain…

Instrumentation and Detectors · Physics 2023-02-15 Matias Senger , Lea Caminada , Benjamin Kilminster , Anna Macchiolo , Beat Meier , Stephan Wiederkehr

During the second LHC long shutdown (LS2) the Inner Tracking System (ITS) of ALICE (A Large Ion Collider Experiment) will be replaced by seven layers of CMOS Monolithic Active Pixel Sensors (MAPS). The latest innovations in silicon imaging…

Nuclear Experiment · Physics 2020-05-01 D. Andreou

Central exclusive processes can be studied in CMS by combining the information of the central detector with the Precision Proton Spectrometer (PPS). PPS detectors, placed symmetrically at more than 200 m from the interaction point, can…

Instrumentation and Detectors · Physics 2020-06-24 Edoardo Bossini