English
Related papers

Related papers: Qualification of Bump Bonding in CMS Inner Tracker…

200 papers

A new Beam Halo Monitor (BHM) detector system has been installed in the CMS cavern to measure the machine-induced background (MIB) from the LHC. This background originates from interactions of the LHC beam halo with the final set of…

Instrumentation and Detectors · Physics 2019-08-13 Kelly Stifter

A novel modular high-resolution charged-particle tracking detector design using $250\mu m$ diameter, round, scintillating fibers and SiPM arrays for readout is presented. The fiber modules consist of 8 layers of 128 fibers, mechanically sta…

Instrumentation and Detectors · Physics 2008-11-26 Henning Gast , Thomas Kirn , Gregorio Roper Yearwood , Stefan Schael

The R&D activity presented is focused on the development of new modules for the upgrade of the ATLAS pixel system at the High Luminosity LHC (HL-LHC). The performance after irradiation of n-in-p pixel sensors of different active thicknesses…

Instrumentation and Detectors · Physics 2015-06-11 A. Macchiolo , L. Andricek , M. Ellenburg , H. G. Moser , R. Nisius , R. H. Richter , S. Terzo , P. Weigell

During the High Luminosity phase of LHC, up to 200 proton-proton collisions per bunch crossing will bring severe challenges for event reconstruction. To mitigate pileup effects, an extended upgrade program of the CMS experiment is expected.…

High Energy Physics - Experiment · Physics 2026-03-23 Simona Palluotto

We report on the 3-year INFN ATLAS-CMS joint research activity in collaboration with FBK, started in 2014, and aimed at the development of new thin pixel detectors for the High Luminosity LHC Phase-2 upgrades. The program is concerned with…

Hybrid pixel detectors require a reliable and cost-effective interconnect technology adapted to the pitch and die sizes of the respective applications. During the ASIC and sensor R\&D phase, especially for small-scale applications, such…

In the last years, high-resolution time tagging has emerged as the tool to tackle the problem of high-track density in the detectors of the next generation of experiments at particle colliders. Time resolutions below 50ps and event average…

The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector volume, for the purpose of fast bunch-by-bunch monitoring…

The oldest and most robust technique to search for new particles is to look for `bumps' in invariant mass spectra over smoothly falling backgrounds. We present a new extension of the bump hunt that naturally benefits from modern machine…

High Energy Physics - Phenomenology · Physics 2019-02-12 Jack H Collins , Kiel Howe , Benjamin Nachman

The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of…

Instrumentation and Detectors · Physics 2021-04-28 B. Acar , G. Adamov , C. Adloff , S. Afanasiev , N. Akchurin , B. Akgün , M. Alhusseini , J. Alison , G. Altopp , M. Alyari , S. An , S. Anagul , I. Andreev , M. Andrews , P. Aspell , I. A. Atakisi , O. Bach , A. Baden , G. Bakas , A. Bakshi , P. Bargassa , D. Barney , E. Becheva , P. Behera , A. Belloni , T. Bergauer , M. Besancon , S. Bhattacharya , S. Bhattacharya , D. Bhowmik , P. Bloch , A. Bodek , M. Bonanomi , A. Bonnemaison , S. Bonomally , J. Borg , F. Bouyjou , D. Braga , J. Brashear , E. Brondolin , P. Bryant , J. Bueghly , B. Bilki , B. Burkle , A. Butler-Nalin , S. Callier , D. Calvet , X. Cao , B. Caraway , S. Caregari , L. Ceard , Y. C. Cekmecelioglu , G. Cerminara , N. Charitonidis , R. Chatterjee , Y. M. Chen , Z. Chen , K. y. Cheng , S. Chernichenko , H. Cheung , C. H. Chien , S. Choudhury , D. Čoko , G. Collura , F. Couderc , I. Dumanoglu , D. Dannheim , P. Dauncey , A. David , G. Davies , E. Day , P. DeBarbaro , F. De Guio , C. de La Taille , M. De Silva , P. Debbins , E. Delagnes , J. M. Deltoro , G. Derylo , P. G. Dias de Almeida , D. Diaz , P. Dinaucourt , J. Dittmann , M. Dragicevic , S. Dugad , V. Dutta , S. Dutta , J. Eckdahl , T. K. Edberg , M. El Berni , S. C. Eno , Yu. Ershov , P. Everaerts , S. Extier , F. Fahim , C. Fallon , B. A. Fontana Santos Alves , E. Frahm , G. Franzoni , J. Freeman , T. French , E. Gurpinar Guler , Y. Guler , M. Gagnan , P. Gandhi , S. Ganjour , A. Garcia-Bellido , Z. Gecse , Y. Geerebaert , H. Gerwig , O. Gevin , W. Gilbert , A. Gilbert , K. Gill , C. Gingu , S. Gninenko , A. Golunov , I. Golutvin , T. Gonzalez , N. Gorbounov , L. Gouskos , Y. Gu , F. Guilloux , E. Gülmez , M. Hammer , A. Harilal , K. Hatakeyama , A. Heering , V. Hegde , U. Heintz , V. Hinger , N. Hinton , J. Hirschauer , J. Hoff , W. S. Hou , C. Isik , J. Incandela , S. Jain , H. R. Jheng , U. Joshi , O. Kara , V. Kachanov , A. Kalinin , R. Kameshwar , A. Kaminskiy , A. Karneyeu , O. Kaya , M. Kaya , A. Khukhunaishvili , S. Kim , K. Koetz , T. Kolberg , A. Kristić , M. Krohn , K. Krüger , N. Kulagin , S. Kulis , S. Kunori , C. M. Kuo , V. Kuryatkov , S. Kyre , O. K. Köseyan , Y. Lai , K. Lamichhane , G. Landsberg , J. Langford , M. Y. Lee , A. Levin , A. Li , B. Li , J. -H. Li , H. Liao , D. Lincoln , L. Linssen , R. Lipton , Y. Liu , A. Lobanov , R. S. Lu , I. Lysova , A. M. Magnan , F. Magniette , A. A. Maier , A. Malakhov , I. Mandjavize , M. Mannelli , J. Mans , A. Marchioro , A. Martelli , P. Masterson , B. Meng , T. Mengke , A. Mestvirishvili , I. Mirza , S. Moccia , I. Morrissey , T. Mudholkar , J. Musić , I. Musienko , S. Nabili , A. Nagar , A. Nikitenko , D. Noonan , M. Noy , K. Nurdan , C. Ochando , B. Odegard , N. Odell , Y. Onel , W. Ortez , J. Ozegović , L. Pacheco Rodriguez , E. Paganis , D. Pagenkopf , V. Palladino , S. Pandey , F. Pantaleo , C. Papageorgakis , I. Papakrivopoulos , J. Parshook , N. Pastika , M. Paulini , P. Paulitsch , T. Peltola , R. Pereira Gomes , H. Perkins , P. Petiot , F. Pitters , F. Pitters , H. Prosper , M. Prvan , I. Puljak , T. Quast , R. Quinn , M. Quinnan , K. Rapacz , L. Raux , G. Reichenbach , M. Reinecke , M. Revering , A. Rodriguez , T. Romanteau , A. Rose , M. Rovere , A. Roy , P. Rubinov , R. Rusack , A. E. Simsek , U. Sozbilir , O. M. Sahin , A. Sanchez , R. Saradhy , T. Sarkar , M. A. Sarkisla , J. B. Sauvan , I. Schmidt , M. Schmitt , E. Scott , C. Seez , F. Sefkow , S. Sharma , I. Shein , A. Shenai , R. Shukla , E. Sicking , P. Sieberer , Y. Sirois , V. Smirnov , E. Spencer , A. Steen , J. Strait , T. Strebler , N. Strobbe , J. W. Su , E. Sukhov , L. Sun , M. Sun , C. Syal , B. Tali , U. G. Tok , A. Kayis Topaksu , C. L. Tan , I. Tastan , T. Tatli , R. Thaus , S. Tekten , D. Thienpont , T. Pierre-Emile , E. Tiras , M. Titov , D. Tlisov , J. Troska , Z. Tsamalaidze , G. Tsipolitis , A. Tsirou , N. Tyurin , S. Undleeb , D. Urbanski , V. Ustinov , A. Uzunian , M. van de Klundert , J. Varela , M. Velasco , M. Vicente Barreto Pinto , P. M. da Silva , T. Virdee , R. Vizinho de Oliveira , J. Voelker , E. Voirin , Z. Wang , X. Wang , F. Wang , M. Wayne , S. N. Webb , M. Weinberg , A. Whitbeck , D. White , R. Wickwire , J. S. Wilson , H. Y. Wu , L. Wu , C. H Yeh , R. Yohay , G. B. Yu , S. S. Yu , D. Yu , F. Yumiceva , A. Zacharopoulou , N. Zamiatin , A. Zarubin , S. Zenz , H. Zhang , J. Zhang

As part of the Compact Muon Solenoid experiment Phase-II upgrade program, new Resistive Plate Chambers will be installed in the forward region. High background conditions are expected in this region during the high-luminosity phase of the…

Instrumentation and Detectors · Physics 2020-06-02 Sabino Meola

The CMS muon system at the LHC is built of different detector technologies. The measurement of the background hit rates in the different muon detectors during the LHC Run-2 is of prime importance for an assessment of the longevity of the…

Instrumentation and Detectors · Physics 2020-04-22 Silvia Costantini

The development of CMOS pixel sensors with column parallel read-out and integrated zero-suppression has resulted in a full size, nearly 1 Megapixel, prototype with ~100 \mu s read-out time. Its performances are quite close to the ILD vertex…

Instrumentation and Detectors · Physics 2010-07-16 Christine Hu-Guo , IPHC Collaboration , IRFU Collaboration

The inner silicon detector of the Compact Muon Solenoid experiment (CMS) at CERN's LHC consists of 16588 modules. Charged-particle tracks in the detector are used to improve the accuracy to which the position and orientation of the modules…

Instrumentation and Detectors · Physics 2015-05-27 Volker Blobel , Claus Kleinwort , Frank Meier

The ALICE Inner Tracking System has been recently upgraded to a full silicon detector consisting entirely of MAPS, arranged in seven concentric layers around the LHC beam pipe. Further ahead, during the LHC Long Shutdown 3, the ALICE…

Instrumentation and Detectors · Physics 2022-09-21 Bogdan-Mihail Blidaru

The electronics used in the data readout and triggering system for the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) particle accelerator at CERN are exposed to high radiation levels. This radiation can cause…

Pixel detectors are used in the innermost part of the multi purpose experiments at LHC and are therefore exposed to the highest fluences of ionising radiation, which in this part of the detectors consists mainly of charged pions. The…

Instrumentation and Detectors · Physics 2010-11-30 T. Rohe , A. Bean , W. Erdmann , H. -C. Kaestli , S. Khalatyan , B. Meier , V. Radicci , J. Sibille

This paper presents the design and results of detailed tests of a CMOS active pixel chip for charged particle detection with in-pixel charge storage for correlated double sampling and readout in rolling shutter mode at frequencies up to 25…

Instrumentation and Detectors · Physics 2009-01-27 Marco Battaglia , Jean-Marie Bussat , Devis Contarato , Peter Denes , Piero Giubilato , Lindsay E. Glesener

The planned upgrade of the LHC accelerator at CERN, namely the high luminosity (HL) phase of the LHC (HL-LHC foreseen for 2023), will result in a more intense radiation environment than the present tracking system was designed for. The…

Instrumentation and Detectors · Physics 2015-12-09 Timo Peltola