Related papers: Simulation-based performance comparison of varied …
In CBM Experiment at FAIR, dimuons will be detected by a Muon Chamber (MUCH) consisting of segmented absorbers of varying widths and tracking chambers sandwiched between the absorber-pairs. In this fixed target heavy-ion collision…
The bulk Micromegas detector is considered to be a promising candidate for building TPCs for several future experiments including the projected linear collider. The standard bulk with a spacing of 128 micron has already established itself…
The thick GEM (THGEM) [1] is an "expanded" GEM, economically produced in the PCB industry by simple drilling and etching in G-10 or other insulating materials (fig. 1). Similar to GEM, its operation is based on electron gas avalanche…
A systematic study is performed to measure the ion backflow fraction of the GEM detectors. The effects of different voltage configurations and Ar/CO_2 gas mixtures, in ratios of 70:30, 80:20 and 90:10, on positive ion fraction are…
A simple X-ray imaging system using off-the-shelf electronics and simple reconstruction algorithms aiming a spatial resolution of 1.7 mm ($\sim 3\,\%$ of the detector length) is described in this work. For this, two 100 cm$^2$ Gas Electron…
The TOTEM experiment at LHC has chosen the triple Gas Electron Multiplier (GEM) technology for its T2 telescope which will provide charged track reconstruction in the rapidity range 5.3<|eta|<6.5 and a fully inclusive trigger for…
Triple Gas Electron Multiplier (GEM) detectors will be used as a tracking device in the first two stations of CBM MUon CHamber (MUCH), where the maximum particle rate is expected to reach ~1 MHz/cm2 for central Au-Au collisions at 8 AGeV.…
The Silicon Electron Multiplier (SiEM) is a novel sensor concept for minimum ionizing particle (MIP) detection which uses internal gain and fine pitch to achieve excellent temporal and spatial resolution. In contrast to sensors where the…
The Gas Electron Multiplier (GEM) is a new age detector, which can handle the high flux of particles. The GEM foil, which is constructed using 50$\mu$m highly insulating foil (Kapton/Apical) coated with 5$\mu$m layers of copper, on both…
A wire GEM (WGEM) detector with a gas gap between meshes was constructed. The detector provides the amplification 5x10E5 for the gas mixture of Ar +20% CO2 at atmospheric pressure. As compared with well-known GEM detectors produced by…
From its invention in 1997, the Gas Electron Multiplier has been applied in nuclear and high energy physics experiments. Over time however, other applications have also exploited the favorable properties of GEMs. The use of GEMs in these…
We present the results of our recent studies on a Thick Gas Electron Multiplier (THGEM)-based imaging detector prototype. It consists of two 100x100 mm^2 THGEM electrodes in cascade, coupled to a resistive anode. The event location is…
We present the first micropattern gaseous detector that employs a small 3D-printed Thick-GEM as its sole gain element. The detector can achieve sufficient gas gain for regular operation without the need for pre-amplification by additional…
An analysis software was developed for the high aspect ratio optical scanning system in the Detec- tor Laboratory of the University of Helsinki and the Helsinki Institute of Physics. The system is used e.g. in the quality assurance of the…
A new concept for a hybrid structure gaseous detector module with ion backflow suppression for the time projection chamber in a future circular collider is presented. It is a hybrid structure cascaded Gas Electron Multiplier (GEM) with a…
We developed a prototype time projection chamber using gas electron multipliers (GEM-TPC) for high energy heavy ion collision experiments. To investigate its performance, we conducted a beam test with 3 kinds of gases (Ar(90%)-CH4(10%),…
The concept of capacitive-sharing readout, described in detail in a previous study, offers the possibility for the development of high-performance three-coordinates (X-Y-U)-strip readout for Micro Pattern Gaseous Detectors (MPGDs) using…
We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron…
In this work a set of simulations that aim at the optimization of gaseous detectors for applications in X-ray fluorescence imaging in the energy range of 3 -- 30keV is presented. By studying the statistical distribution of the radiation…
Micro-pattern gas detectors, such as the Gas Electron Multiplier (GEM) and the Micromegas need narrow high density anode readout elements to achieve good spatial resolution. A high-density anode readout would require an unmanageable number…