English
Related papers

Related papers: Simulation-based performance comparison of varied …

200 papers

The recently completed Forward GEM Tracker (FGT) of the STAR experiment at RHIC took advantage of commercially produced GEM foils based on double-mask chemical etching techniques. With future experiments proposing detectors that utilize…

Instrumentation and Detectors · Physics 2014-11-27 M. Posik , B. Surrow

A triple-GEM detector with two-dimensional readout is developed. The detector provides high position resolution for powder diffraction experiments at synchrotron radiation. Spatial resolution of the detector is measured in the lab using a…

Instrumentation and Detectors · Physics 2017-04-12 Y. L. Zhang , H. R. Qi , Z. W. Wen , H. Y. Wang , Q. Ouyang , Y. B. Chen , J. Zhang , B. T. Hu

For its physics program with a high-intensity hadron beam of up to 2e7 particles/s, the COMPASS experiment at CERN requires tracking of charged particles scattered by very small angles with respect to the incident beam direction. While good…

A prototype Dual Gain Multilayer Thick Gas Electron Multilyer (DG-M-THGEM) with an active area of 10 cm $\times$ 10 cm was manufactured aiming at the production of a large-volume active-target time projection chamber which can work under…

A novel instrument has been developed to monitor and record the ambient pa- rameters such as temperature, atmospheric pressure and relative humidity. These parameters are very essential for understanding the characteristics such as gain of…

Instrumentation and Detectors · Physics 2015-07-15 S. Sahu , M. R. Bhuyan , Sharmili Rudra , S. Biswas , B. Mohanty , P. K. Sahu

Many experiments are currently using or proposing to use large area GEM foils in their detectors, which is creating a need for commercially available GEM foils. Currently CERN is the only main distributor of GEM foils, however with the…

Instrumentation and Detectors · Physics 2016-01-15 M. Posik , B. Surrow

The occurrence of electrical discharges in gas detectors restricts their dynamic range and degrades their performance. Among the different methods developed to mitigate discharge effects, the use of resistive materials in the detector…

Instrumentation and Detectors · Physics 2022-11-16 Abhik Jash , Luca Moleri , Shikma Bressler

In this paper, the design and the performance of a prototype detector based on MicroMegas technology with two detection planes in a common gas volume is discussed. The detector is suited for the forward region of LHC detectors, addressing…

Instrumentation and Detectors · Physics 2017-06-28 Bernard Brickwedde , Andreas Düdder , Matthias Schott , Eda Yildirim

Working gas components significantly impact the performance of gaseous detectors. A fast-timing Micromegas detector with two-stage amplification is prone to notable deterioration of uniformity when scaled up. This paper presents a…

Instrumentation and Detectors · Physics 2024-11-08 Yue Meng , Xu Wang , Jianbei Liu , Ming Shao , Zhiyong Zhang , Yi Zhou

The muon detection system of the Compact Muon Solenoid experiment at the CERN Large Hadron Collider is based on different technologies for muon tracking and triggering. In particular, the muon system in the endcap disks of the detector…

Measurements and numerical simulations on the charge transfer in Gas Electron Multiplier (GEM) foils are presented and their implications for the usage of GEM foils in Time Projection Chambers are discussed. A small test chamber has been…

Instrumentation and Detectors · Physics 2009-09-29 M. Killenberg , S. Lotze , J. Mnich , S. Roth , R. Schulte , B. Sobloher , W. Struczinski , M. Tonutti

This works reports on gaseous detectors developments made in the frame of the EXO double-beta decay experiment. LEM (Large Electron Multiplication) are electron amplification grids based on GEM. They were developed in Neuchatel and showed…

Instrumentation and Detectors · Physics 2007-06-12 Patrick Weber

In view of a possible extension of the forward CMS muon detector system and future LHC luminosity upgrades, Micro-Pattern Gas Detectors (MPGDs) are an appealing technology. They can simultaneously provide precision tracking and fast trigger…

The performance and long term stability of an optically readout Time Projection Chamber with an electron amplification structure based on three Gas Electron Multipliers was studied. He/CF$_4$ based gas mixtures were used in two different…

We present a gas selection for Xe-based gas electron multiplier (GEM) detectors, Gas Multiplier Counters (GMCs) onboard the CubeSat X-ray observatory NinjaSat. To achieve an energy bandpass of 2-50 keV, we decided to use a Xe-based gas…

A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget…

Instrumentation and Detectors · Physics 2017-06-02 M. Dragicevic , M. Friedl , J. Hrubec , H. Steininger , A. Gädda , J. Härkönen , T. Lampén , P. Luukka , T. Peltola , E. Tuominen , E. Tuovinen , A. Winkler , P. Eerola , T. Tuuva , G. Baulieu , G. Boudoul , L. Caponetto , C. Combaret , D. Contardo , T. Dupasquier , G. Gallbit , N. Lumb , L. Mirabito , S. Perries , M. Vander Donckt , S. Viret , C. Bonnin , L. Charles , L. Gross , J. Hosselet , D. Tromson , L. Feld , W. Karpinski , K. Klein , M. Lipinski , G. Pierschel , M. Preuten , M. Rauch , M. Wlochal , M. Aldaya , C. Asawatangtrakuldee , K. Beernaert , D. Bertsche , C. Contreras-Campana , G. Eckerlin , D. Eckstein , T. Eichhorn , E. Gallo , J. Garay Garcia , K. Hansen , M. Haranko , A. Harb , J. Hauk , J. Keaveney , A. Kalogeropoulos , C. Kleinwort , W. Lohmann , R. Mankel , H. Maser , G. Mittag , C. Muhl , A. Mussgiller , D. Pitzl , O. Reichelt , M. Savitskyi , P. Schütze , V. Sola , S. Spannagel , R. Walsh , A. Zuber , H. Biskop , P. Buhmann , M. Centis-Vignali , E. Garutti , J. Haller , M. Hoffmann , R. Klanner , T. Lapsien , M. Matysek , A. Perieanu , Ch. Scharf , P. Schleper , A. Schmidt , J. Schwandt , J. Sonneveld , G. Steinbrück , B. Vormwald , J. Wellhausen , M. Abbas , C. Amstutz , T. Barvich , Ch. Barth , F. Boegelspacher , W. De Boer , E. Butz , M. Casele , F. Colombo , A. Dierlamm , B. Freund , F. Hartmann , S. Heindl , U. Husemann , A. Kornmeyer , S. Kudella , Th. Muller , H. J. Simonis , P. Steck , M. Weber , Th. Weiler , T. Kiss , F. Siklér , T. Tölyhi , V. Veszprémi , P. Cariola , D. Creanza , M. De Palma , G. De Robertis , L. Fiore , M. Franco , F. Loddo , G. Sala , L. Silvestris , G. Maggi , S. My , G. Selvaggi , S. Albergo , G. Cappello , S. Costa , A. Di Mattia , F. Giordano , R. Potenza , M. A. Saizu , A. Tricomi , C. Tuve , E. Focardi , M. E. Dinardo , S. Fiorendi , S. Gennai , S. Malvezzi , R. A. Manzoni , D. Menasce , L. Moroni , D. Pedrini , P. Azzi , N. Bacchetta , D. Bisello , M. Dall'Osso , N. Pozzobon , M. Tosi , L. Alunni Solestizi , M. Biasini , G. M. Bilei , C. Cecchi , B. Checcucci , D. Ciangottini , L. Fanò , C. Gentsos , M. Ionica , R. Leonardi , E. Manoni , G. Mantovani , S. Marconi , V. Mariani , M. Menichelli , A. Modak , A. Morozzi , F. Moscatelli , D. Passeri , P. Placidi , V. Postolache , A. Rossi , A. Saha , A. Santocchia , L. Storchi , D. Spiga , K. Androsov , P. Azzurri , G. Bagliesi , A. Basti , T. Boccali , L. Borrello , F. Bosi , R. Castaldi , M. Ceccanti , M. A. Ciocci , R. Dell'Orso , S. Donato , G. Fedi , A. Giassi , M. T. Grippo , F. Ligabue , G. Magazzu , P. Mammini , F. Mariani , E. Mazzoni , A. Messineo , A. Moggi , F. Morsani , F. Palla , F. Palmonari , A. Profeti , F. Raffaelli , A. Ragonesi , A. Rizzi , A. Soldani , P. Spagnolo , R. Tenchini , G. Tonelli , A. Venturi , P. G. Verdini , D. Abbaneo , I. Ahmed , E. Albert , G. Auzinger , G. Berruti , J. Bonnaud , J. Daguin , A. D'Auria , S. Detraz , O. Dondelewski , B. Engegaard , F. Faccio , N. Frank , K. Gill , A. Honma , A. Kornmayer , A. Labaza , F. Manolescu , I. McGill , S. Mersi , S. Michelis , A. Onnela , M. Ostrega , S. Pavis , A. Peisert , J. -F. Pernot , P. Petagna , H. Postema , K. Rapacz , C. Sigaud , P. Tropea , J. Troska , A. Tsirou , F. Vasey , B. Verlaat , P. Vichoudis , L. Zwalinski , F. Bachmair , R. Becker , D. di Calafiori , B. Casal , P. Berger , L. Djambazov , M. Donega , C. Grab , D. Hits , J. Hoss , G. Kasieczka , W. Lustermann , B. Mangano , M. Marionneau , P. Martinez Ruiz del Arbol , M. Masciovecchio , M. Meinhard , L. Perozzi , U. Roeser , A. Starodumov , V. Tavolaro , R. Wallny , D. Zhu , K. Bösiger , L. Caminada , F. Canelli , V. Chiochia , A. de Cosa , C. Galloni , T. Hreus , B. Kilminster , C. Lange , R. Maier , J. Ngadiuba , D. Pinna , P. Robmann , S. Taroni , Y. Yang , W. Bertl , K. Deiters , W. Erdmann , R. Horisberger , H. -C. Kaestli , D. Kotlinski , U. Langenegger , B. Meier , T. Rohe , S. Streuli , P. -H. Chen , C. Dietz , F. Fiori , U. Grundler , W. -S. Hou , R. -S. Lu , M. Moya , J. -F. Tsai , Y. M. Tzeng , D. Cussans , J. Goldstein , M. Grimes , D. Newbold , P. Hobson , I. D. Reid , G. Auzinger , R. Bainbridge , P. Dauncey , G. Hall , T. James , A. -M. Magnan , M. Pesaresi , D. M. Raymond , K. Uchida , T. Durkin , K. Harder , C. Shepherd-Themistocleous , M. Chertok , J. Conway , R. Conway , C. Flores , R. Lander , D. Pellett , F. Ricci-Tam , M. Squires , J. Thomson , R. Yohay , K. Burt , J. Ellison , G. Hanson , M. Olmedo , W. Si , B. R. Yates , A. Dominguez , R. Bartek , B. Bentele , J. P. Cumalat , W. T. Ford , F. Jensen , A. Johnson , M. Krohn , S. Leontsinis , T. Mulholland , K. Stenson , S. R. Wagner , A. Apresyan , G. Bolla , K. Burkett , J. N. Butler , A. Canepa , H. W. K. Cheung , D. Christian , W. E. Cooper , G. Deptuch , G. Derylo , C. Gingu , S. Grünendahl , S. Hasegawa , J. Hoff , J. Howell , M. Hrycyk , S. Jindariani , M. Johnson , F. Kahlid , S. Kwan , C. M. Lei , R. Lipton , R. Lopes De Sá , T. Liu , S. Los , M. Matulik , P. Merkel , S. Nahn , A. Prosser , R. Rivera , B. Schneider , G. Sellberg , A. Shenai , K. Siehl , L. Spiegel , N. Tran , L. Uplegger , E. Voirin , D. R. Berry , X. Chen , L. Ennesser , A. Evdokimov , C. E. Gerber , S. Makauda , C. Mills , I. D. Sandoval Gonzalez , J. Alimena , L. J. Antonelli , B. Francis , A. Hart , C. S. Hill , N. Parashar , J. Stupak , D. Bortoletto , M. Bubna , N. Hinton , M. Jones , D. H. Miller , X. Shi , P. Baringer , A. Bean , S. Khalil , A. Kropivnitskaya , D. Majumder , E. Schmitz , G. Wilson , A. Ivanov , R. Mendis , T. Mitchell , N. Skhirtladze , R. Taylor , I. Anderson , D. Fehling , A. Gritsan , P. Maksimovic , C. Martin , K. Nash , M. Osherson , M. Swartz , M. Xiao , J. G. Acosta , L. M. Cremaldi , S. Oliveros , L. Perera , D. Summers , K. Bloom , D. R. Claes , C. Fangmeier , R. Gonzalez Suarez , J. Monroy , J. Siado , E. Bartz , Y. Gershtein , E. Halkiadakis , S. Kyriacou , A. Lath , K. Nash , M. Osherson , S. Schnetzer , R. Stone , M. Walker , S. Malik , S. Norberg , J. E. Ramirez Vargas , M. Alyari , J. Dolen , A. Godshalk , C. Harrington , I. Iashvili , A. Kharchilava , D. Nguyen , A. Parker , S. Rappoccio , B. Roozbahani , J. Alexander , J. Chaves , J. Chu , S. Dittmer , K. McDermott , N. Mirman , A. Rinkevicius , A. Ryd , E. Salvati , L. Skinnari , L. Soffi , Z. Tao , J. Thom , J. Tucker , M. Zientek , B. Akgün , K. M. Ecklund , M. Kilpatrick , T. Nussbaum , J. Zabel , P. D'Angelo , W. Johns , K. Rose

In this work we show the operation and results of an X-ray fluorescence imaging system using a cascade of three gas electron multipliers (GEM) and a pinhole assembly. The detector operates in Ar/CO$_2$ (90/10) at atmospheric pressure, with…

Instrumentation and Detectors · Physics 2019-06-26 Geovane G. A. de Souza , Hugo Natal da Luz

We report on the results of an extensive R&D program aimed at the evaluation of Thick-Gas Electron Multipliers (THGEM) as potential active elements for Digital Hadron Calorimetry (DHCAL). Results are presented on efficiency, pad…

The Beijing Spectrometer (BESIII) is an experimental setup located at the Beijing Electron Positron Collider (BEPCII). The recently approved ten-year extension of data acquisition for BESIII prompted an upgrade program for both the BEPCII…

Instrumentation and Detectors · Physics 2021-11-17 Alberto Bortone

A gallium arsenide detector was tested with a beam of 70GeV pions at the {\sf SPS} at CERN. The detector utilises a novel biasing scheme which has been shown to behave as expected. The detector has a pitch of 50$\mu$m and therefore an…

High Energy Physics - Experiment · Physics 2007-05-23 S. Gowdy
‹ Prev 1 8 9 10 Next ›