We report measurements characterizing the performance of a kinetic inductance detector array designed for a wavelength of 25 microns and very low optical background level suitable for applications such as a far-infrared instrument on a…
We describe the design and measurement of feedhorn-coupled, transition-edge sensor (TES) polarimeters with two passbands centered at 220 GHz and 280 GHz, intended for observations of the cosmic microwave background. Each pixel couples…
Optical measurements of a nanoscale silicon optomechanical crystal cavity with a mechanical resonance frequency of 3.6GHz are performed at sub-kelvin temperatures. We infer optical-absorption-induced heating and damping of the mechanical…
Techniques to mold the flow of light on subwavelength scales enable fundamentally new optical systems and device applications. The realization of programmable, active optical systems with fast, tunable components is among the outstanding…
Optoelectronic functionalities of photodection and light harnessing rely on the band-to-band excitation of semiconductors, thus the spectral response of the devices is dictated and limited by their bandgap. A novel approach, free from this…
Several on-going and future experiments use a Stokes polarimeter (i.e. a rotating wave plate followed by a steady polarizer and by an unpolarized detector) to measure the small polarized component of the Cosmic Microwave Background. The…
Recent quantum technologies have established precise quantum control of various microscopic systems using electromagnetic waves. Interfaces based on cryogenic cavity electro-optic systems are particularly promising, due to the direct…
Cryogenic calorimeters for low-mass dark matter searches have achieved sub-eV energy resolutions, driving advances in both low-energy calibration techniques and our understanding of detector physics. The energy deposition spectrum of gamma…
We present a superconducting microresonator thermometer based on two-level systems (TLS) that is drop-in compatible with cryogenic microwave systems. The operational temperature range is 50-1000~mK (which may be extended to 5~mK), and the…
We present an infrared photodetector leveraging an all-epitaxial device architecture consisting of a 'designer' plasmonic metal integrated with a quantum-engineered detector structure, all in a mature III-V semiconductor material system.…
A vacuum compatible cryogenic accelerometer is presented which will reach $<0.5$ p$g$ Hz$^{-1/2}$ sensitivity from 1 mHz to 10 Hz with a maximum sensitivity of 10 f$g$ Hz$^{-1/2}$ around 10 Hz. This figure can be translated to a…
Recent advances in far-infrared detector technology have led to increases in raw sensitivity of more than an order of magnitude over previous state-of-the-art detectors. With such sensitivity, photon noise becomes the dominant noise…
Ultrastable lasers serve as the backbone for some of the most advanced scientific experiments today and enable the ability to perform atomic spectroscopy and laser interferometry at the highest levels of precision possible. With the recent…
The frequency stability of lasers is limited by thermal noise in state-of-the-art frequency references. Further improvement requires operation at cryogenic temperature. In this context, we investigate a fiber-based ring resonator. Our…
Thermal noise is the predominant instability in the provision of ultrastable laser frequency, referencing to an optical cavity. Reducing the thermal-noise limit of a cavity means either making it larger to spread thermal fluctuations,…
Pulse compression processing based on stimulated Brillouin scattering (SBS) in an optical fiber is theoretically and experimentally demonstrated. Broadband microwave signal is electro-optically modulated onto the pump lightwave that is…
Superconducting quantum computing has the potential to revolutionize computational capabilities. However, scaling up large quantum processors is limited by the cumbersome and heat-conductive electronic cables that connect room-temperature…
While the thermal and electromagnetic properties of plasmonic nanostructures are well understood, nanoscale thermometry still presents an experimental and theoretical challenge. Plasmonic structures can confine electromagnetic energy at the…
Using a matter wave lens and a long time-of-flight, we cool an ensemble of Rb-87 atoms in two dimensions to an effective temperature of less than $50^{+50}_{-30}$~pK. A short pulse of red-detuned light generates an optical dipole force that…
We describe the design of a cryogenic rotation stage (CRS) for use with the cryogenic half-wave plate (CHWP) polarization modulator on the POLARBEAR-2b and POLARBEAR-2c (PB2b/c) cosmic microwave background (CMB) experiments, the second and…