We extend the analysis of photon coincidence spectroscopy beyond bichromatic excitation and two-photon coincidence detection to include multichromatic excitation and multiphoton coincidence detection. Trichromatic excitation and…
The fast scintillation decay time and the high scintillation yield of liquid xenon makes it an appropriate material for nuclear medicine. Moreover, being a continuous medium with a uniform response, liquid xenon allows one to avoid most of…
Recent studies of positron emission tomography (PET) devices have shown that the detection of polarization-correlated annihilation quanta can potentially reduce the background and creation of false lines of response (LORs) leading to…
Scintillation detectors with excellent timing resolution enable more precise localization of radiation sources in positron emission tomography, leading to substantial improvements in diagnostic capability for diseases such as cancer and…
This work aims at applying the theory of the component-based normalization for the Jagiellonian PET scanner, currently under development at the Jagiellonian University. In any Positron Emission Tomography acquisition, efficiency along a…
Liquid xenon offers several features, which make it suitable for applications in nuclear medicine, such as high scintillation yield and fast scintillation decay time. Moreover, being a continuous medium with a uniform response, liquid xenon…
We study the photon trident process, where an initial photon turns into an electron-positron pair and a final photon under a nonlinear interaction with a strong plane-wave background field. We show that this process is very similar to…
Positron emission tomography, like many other tomographic imaging modalities, relies on an image reconstruction step to produce cross-sectional images from projection data. Detection and localization of the back-to-back annihilation photons…
We report on an hybrid in-beam PET and prompt-gamma Compton imaging system aimed at quasi real-time ion-range verification in proton-therapy treatments. Proof-of-concept experiments were carried out at the radiobiology beam line of the CNA…
Purpose: The scattering phenomenon creates degrading effects in positron emission tomography (PET) and the corresponding events are rejected conventionally. We have proposed a mathematical model to retrace the original line of response of…
The purpose of this study was to show how advanced concepts of compact, lossless and "Time Of Flight" (TOF) capable electronics similar to those foreseen for the LHC and ILC experiments could be fairly and easily transferred to the medical…
The two-photon positron annihilation density matrix is found to separate into a diagonal center of energy factor implying maximally entangled momenta, and a relative factor describing decay. For unknown positron injection time, the…
Readout multiplexing is a promising solution to overcome hardware limitations and data bottlenecks in imaging with single-photon detectors. Conventional multiplexed readout processing creates an upper bound on photon counts at a very fine…
The J-PET detector being developed at Jagiellonian University, is a Positron Emission Tomograph composed of the long strips of polymer scintillators. At the same time it is a detector system which will be used for studies of the decays of…
Here we describe an advanced multi functional, variable-energy positron beam system capable of measuring the energies of multiple positron-induced electrons in coincidence with the Doppler-shifted gamma photon resulting from the…
Photon number resolving detectors are needed for a variety of applications including linear-optics quantum computing. Here we describe the use of time-multiplexing techniques that allows ordinary single photon detectors, such as silicon…
Positronium is the short-lived atom consisting of a bound electron-positron pair. In the triplet state, when the spins of both particles are parallel, radiative recombination lines will be emitted prior to annihilation. The existence of…
Scattered coincidences introduce quantitative bias in positron emission tomography (PET) and must be compensated during reconstruction. Conventional scatter estimates typically rely on simplified cylindrical scanner models that omit…
Acolinearity of the annihilation photons observed in Positron Emission Tomography (PET) is described as following a Gaussian distribution. However, it is never explicitly said if it refers to the amplitude of the acolinearity angle or its…
Purpose: 44Sc has been successfully produced, synthesized, labeled and first-in-human studies were conducted some years ago. The decay properties of 44Sc, together with being close to a clinical implementation, make it an ideal candidate…