Related papers: Is fitting error a reliable metric for assessing d…
We define a regularized size-shape distortion (quality) measure for curved high-order elements on a Riemannian space. To this end, we measure the deviation of a given element, straight-sided or curved, from the stretching, alignment, and…
Motion-related artifacts are inevitable in Magnetic Resonance Imaging (MRI) and can bias automated neuroanatomical metrics such as cortical thickness. These biases can interfere with statistical analysis which is a major concern as motion…
Accurate cardiac motion estimation from cine cardiac magnetic resonance (CMR) images is vital for assessing cardiac function and detecting its abnormalities. Existing methods often struggle to capture heart motion accurately because they…
In imaging inverse problems, we would like to know how close the recovered image is to the true image in terms of full-reference image quality (FRIQ) metrics like PSNR, SSIM, LPIPS, etc. This is especially important in safety-critical…
Magnetic Resonance Imaging (MRI) is a powerful medical imaging modality, but unfortunately suffers from long scan times which, aside from increasing operational costs, can lead to image artifacts due to patient motion. Motion during the…
Fetal functional Magnetic Resonance Imaging (fMRI) has emerged as a powerful tool for investigating brain development in utero, holding promise for generating developmental disease biomarkers and supporting prenatal diagnosis. However, to…
The correlation of optical measurements with a correct pathology label is often hampered by imprecise registration caused by deformations in histology images. This study explores an automated multi-modal image registration technique…
Longitudinal MRI is an important diagnostic imaging tool for evaluating the effects of treatment and monitoring disease progression. However, MRI, and particularly longitudinal MRI, is known to be time consuming. To accelerate imaging,…
Cardiac T1 mapping is a valuable quantitative MRI technique for diagnosing diffuse myocardial diseases. Traditional methods, relying on breath-hold sequences and cardiac triggering based on an ECG signal, face challenges with patient…
A physical magnetic field has a divergence of zero. Numerical error in constructing a model field and computing the divergence, however, introduces a finite divergence into these calculations. A popular metric for measuring divergence is…
While machine learning approaches perform well on their training domain, they generally tend to fail in a real-world application. In cardiovascular magnetic resonance imaging (CMR), respiratory motion represents a major challenge in terms…
Most approaches to camera calibration rely on calibration targets of well-known geometry. During data acquisition, calibration target and camera system are typically moved w.r.t. each other, to allow image coverage and perspective…
We consider quantum metrology in noisy environments, where the effect of noise and decoherence limits the achievable gain in precision by quantum entanglement. We show that by using tools from quantum error-correction this limitation can be…
Online extrinsic calibration is crucial for building "power-on-and-go" moving platforms, like robots and AR devices. However, blindly performing online calibration for unobservable parameter may lead to unpredictable results. In the…
The impact of in-scanner motion on functional magnetic resonance imaging (fMRI) data has a notorious reputation in the neuroimaging community. State-ofthe-art guidelines advise to scrub out excessively corrupted frames as assessed by a…
We introduce spatial deformations to an array of light sources and study how the estimation precision of the interspacing distance, d, changes with the sources of light used. The quantum Fisher information (QFI) is used as the figure of…
Quantitative Magnetic Resonance Imaging (MRI) is based on a two-steps approach: estimation of the magnetic moments distribution inside the body, followed by a voxel-by-voxel quantification of the human tissue properties. This splitting…
Kinematic fitting is a well-established tool to improve jet energy and invariant mass resolutions by fitting the measured values under constraints (e.g. energy conservation). However, in the presence of substantial ISR and Beamstrahlung,…
Quantitative magnetic resonance imaging (qMRI) allows images to be compared across sites and time points, which is particularly important for assessing long-term conditions or for longitudinal studies. The multiparametric mapping (MPM)…
The miniaturization of inertial measurement units (IMUs) facilitates their widespread use in a growing number of application domains. Orientation estimation is a prerequisite for most further data processing steps in inertial motion…