English
Related papers

Related papers: SynthRAD2025 Grand Challenge dataset: generating s…

200 papers

Purpose: Medical imaging has become increasingly important in diagnosing and treating oncological patients, particularly in radiotherapy. Recent advances in synthetic computed tomography (sCT) generation have increased interest in public…

Radiation therapy (RT) requires precise dose delivery over multiple fractions, with CT fundamental for treatment planning due to its electron density information. Repeated CT acquisitions impose radiation exposure and logistical burdens,…

Image synthesis is used to generate synthetic CTs (sCTs) from on-treatment cone-beam CTs (CBCTs) with a view to improving image quality and enabling accurate dose computation to facilitate a CBCT-based adaptive radiotherapy workflow. As…

Image and Video Processing · Electrical Eng. & Systems 2023-12-05 Chelsea A. H. Sargeant , Edward G. A. Henderson , Dónal M. McSweeney , Aaron G. Rankin , Denis Page

The generation of synthetic CT (sCT) images from cone-beam CT (CBCT) data using deep learning methodologies represents a significant advancement in radiation oncology. This systematic review, following PRISMA guidelines and using the PICO…

Image and Video Processing · Electrical Eng. & Systems 2025-01-27 Alzahra Altalib , Scott McGregor , Chunhui Li , Alessandro Perelli

Purpose: Magnetic resonance imaging (MRI) to visualize anatomical motion is becoming increasingly important when treating cancer patients with radiotherapy. Hybrid MRI-linear accelerator (MRI-linac) systems allow real-time motion management…

The generation of Synthetic Computed Tomography (sCT) images has become a pivotal methodology in modern clinical practice, particularly in the context of Radiotherapy (RT) treatment planning. The use of sCT enables the calculation of doses,…

Purpose: Accurate dose calculation is essential in radiotherapy for precise tumor irradiation while sparing healthy tissue. With the growing adoption of MRI-guided and real-time adaptive radiotherapy, fast and accurate dose calculation on…

Generating synthetic CT (sCT) from MRI or CBCT plays a crucial role in enabling MRI-only and CBCT-based adaptive radiotherapy, improving treatment precision while reducing patient radiation exposure. To address this task, we adopt a fully…

Computer Vision and Pattern Recognition · Computer Science 2026-04-24 Arnela Hadzic , Simon Johannes Joham , Martin Urschler

Despite technological and medical advances, the detection, interpretation, and treatment of cancer based on imaging data continue to pose significant challenges. These include inter-observer variability, class imbalance, dataset shifts,…

Image and Video Processing · Electrical Eng. & Systems 2022-11-29 Richard Osuala , Kaisar Kushibar , Lidia Garrucho , Akis Linardos , Zuzanna Szafranowska , Stefan Klein , Ben Glocker , Oliver Diaz , Karim Lekadir

AI requires extensive datasets, while medical data is subject to high data protection. Anonymization is essential, but poses a challenge for some regions, such as the head, as identifying structures overlap with regions of clinical…

Cone-Beam Computed Tomography (CBCT) is widely used for intraoperative imaging due to its rapid acquisition and low radiation dose. However, CBCT images typically suffer from artifacts and lower visual quality compared to conventional…

Image and Video Processing · Electrical Eng. & Systems 2025-07-09 Maximilian Tschuchnig , Lukas Lamminger , Philipp Steininger , Michael Gadermayr

Computer-aided tumor detection has shown great potential in enhancing the interpretation of over 80 million CT scans performed annually in the United States. However, challenges arise due to the rarity of CT scans with tumors, especially…

Image and Video Processing · Electrical Eng. & Systems 2024-09-11 Qi Chen , Yuxiang Lai , Xiaoxi Chen , Qixin Hu , Alan Yuille , Zongwei Zhou

In modern cancer research, the vast volume of medical data generated is often underutilised due to challenges related to patient privacy. The OncoReg Challenge addresses this issue by enabling researchers to develop and validate image…

Cone-Beam Computed Tomography (CBCT) is widely used for real-time intraoperative imaging due to its low radiation dose and high acquisition speed. However, despite its high resolution, CBCT suffers from significant artifacts and thereby…

Image and Video Processing · Electrical Eng. & Systems 2025-06-11 Maximilian Tschuchnig , Lukas Lamminger , Philipp Steininger , Michael Gadermayr

A key challenge for the development and deployment of artificial intelligence (AI) solutions in radiology is solving the associated data limitations. Obtaining sufficient and representative patient datasets with appropriate annotations may…

Image and Video Processing · Electrical Eng. & Systems 2024-07-03 Elena Sizikova , Andreu Badal , Jana G. Delfino , Miguel Lago , Brandon Nelson , Niloufar Saharkhiz , Berkman Sahiner , Ghada Zamzmi , Aldo Badano

We introduce a new dataset called Synthetic COVID-19 Chest X-ray Dataset for training machine learning models. The dataset consists of 21,295 synthetic COVID-19 chest X-ray images to be used for computer-aided diagnosis. These images,…

Image and Video Processing · Electrical Eng. & Systems 2021-06-21 Hasib Zunair , A. Ben Hamza

MR imaging will play a very important role in radiotherapy treatment planning for segmentation of tumor volumes and organs. However, the use of MR-based radiotherapy is limited because of the high cost and the increased use of metal…

Computer Vision and Pattern Recognition · Computer Science 2018-09-05 Cheng-Bin Jin , Hakil Kim , Wonmo Jung , Seongsu Joo , Ensik Park , Ahn Young Saem , In Ho Han , Jae Il Lee , Xuenan Cui

Purpose: Organ-at-risk (OAR) delineation is a key step for cone-beam CT (CBCT) based adaptive radiotherapy planning that can be a time-consuming, labor-intensive, and subject-to-variability process. We aim to develop a fully automated…

Accurate MR-to-CT synthesis is a requirement for MR-only workflows in radiotherapy (RT) treatment planning. In recent years, deep learning-based approaches have shown impressive results in this field. However, to prevent downstream errors…

Image and Video Processing · Electrical Eng. & Systems 2019-11-13 Louis D. van Harten , Jelmer M. Wolterink , Joost J. C. Verhoeff , Ivana Išgum
‹ Prev 1 2 3 10 Next ›