Related papers: B1+ mapping near metallic implants using turbo spi…
Purpose: To develop and validate a multi-parametric SAturation-recovery single-SHot Acquisition (mSASHA) cardiac T1 and T2 mapping technique with high accuracy and precision in a single breath-hold. Methods: The mSASHA acquisition consists…
Brightness mode (B-mode) ultrasound is a common imaging modality in the clinical assessment of several cardiovascular diseases. The utility of ultrasound-based functional indices such as the ejection fraction (EF) and stroke volume (SV) is…
Purpose: Echo modulation curve (EMC) modeling can provide accurate and reproducible quantification of T2 relaxation times. The standard EMC-T2 mapping framework, however, requires sufficient echoes and cumbersome pixel-wise…
Zero echo time (ZTE) sequences have proven a powerful tool for Magnetic Resonance Imaging (MRI) of ultrashort T2 tissues, but they fail to produce useful images in the presence of strong field inhomogeneities. Here we present a method to…
Cardiac T1 mapping is a valuable quantitative MRI technique for diagnosing diffuse myocardial diseases. Traditional methods, relying on breath-hold sequences and cardiac triggering based on an ECG signal, face challenges with patient…
We consider a missing data problem in the context of automatic segmentation methods for Magnetic Resonance Imaging (MRI) brain scans. Usually, automated MRI scan segmentation is based on multiple scans (e.g., T1-weighted, T2-weighted, T1CE,…
Ultrahigh-field MRI, such as those operating at 7 Tesla, enhances diagnostic capabilities but also presents unique challenges, including the need for advanced RF coil designs to achieve an optimal signal-to-noise ratio and transmit…
Magnetic Resonance Imaging (MRI) is a widely used medical imaging modality boasting great soft tissue contrast without ionizing radiation, but unfortunately suffers from long acquisition times. Long scan times can lead to motion artifacts,…
Quantitative ultrasound, e.g., speed-of-sound (SoS) in tissues, provides information about tissue properties that have diagnostic value. Recent studies showed the possibility of extracting SoS information from pulse-echo ultrasound raw data…
Purpose: To develop and evaluate a free-breathing respiratory motion compensated 4D (3D+respiration) $T_2$-weighted turbo spin echo sequence with application to radiology and MR-guided radiotherapy. Methods: k-space data are continuously…
In radial fast spin-echo MRI, a set of overlapping spokes with an inconsistent T2 weighting is acquired, which results in an averaged image contrast when employing conventional image reconstruction techniques. This work demonstrates that…
Purpose: To develop a method for rapid sub-millimeter T1, T2, T2* and QSM mapping in a single scan using multi-contrast Learned Acquisition and Reconstruction Optimization (mcLARO). Methods: A pulse sequence was developed by interleaving…
Recent studies on T1-assisted MRI reconstruction for under-sampled images of other modalities have demonstrated the potential of further accelerating MRI acquisition of other modalities. Most of the state-of-the-art approaches have achieved…
Cardiac T1 mapping can evaluate various clinical symptoms of myocardial tissue. However, there is currently a lack of effective, robust, and efficient methods for motion correction in cardiac T1 mapping. In this paper, we propose a deep…
This paper presents a closed-loop magnetic manipulation framework for robotic transesophageal echocardiography (TEE) acquisitions. Different from previous work on intracorporeal robotic ultrasound acquisitions that focus on continuum robot…
An extended aperture has the potential to greatly improve ultrasound imaging performance. This work extends the effective aperture size by coherently compounding the received radio frequency data from multiple transducers. A framework is…
Quantitative MRI methods that estimate multiple physical parameters simultaneously often require the fitting of a computational complex signal model defined through the Bloch equations. Repeated Bloch simulations can be avoided by matching…
Industry standards require medical device manufacturers to perform implant-induced artefact testing in phantoms at a pre-clinical stage to define the extent of artefacts that can be expected during MRI. Once a device is commercially…
Spin-based quantum computing and magnetic resonance techniques rely on the ability to measure the coherence time, T2, of a spin system. We report on the experimental implementation of all-optical spin echo to determine the T2 time of a…
Medical ultrasound (US) imaging is widely used in clinical examinations due to its portability, real-time capability, and radiation-free nature. To address inter- and intra-operator variability, robotic ultrasound systems have gained…